TABLE 2.  FRC-753 RT CHANNEL UNIT TURN-UP AND TESTING

CAUTION

Observe normal electrostatic discharge precautions when handling electronic equipment. Do not hold electronic plugs by

their connector edges. Do not touch components or circuitry.

Step

Operation

Action

Observe

1

Install RT
Channel Units

a. Insert each FRC-753 Channel

Unit into the FRE-765 RT
Enclosure.

All LEDs on the Channel Unit will turn on for approximately
2 seconds, then scan from top to bottom, then turn off.

b. After the system has powered

up, established HDSL
synchronized communications,
and no calls are in progress,
observe the Channel Unit front
panel indicators.

ACTIVE 1 

off

ACTIVE 2 

off

ACTIVE 3 

off

ACTIVE 4 

off

ACTIVE 5

off

ACTIVE 6

off

ACTIVE 7

off

ACTIVE 8

off

FAULT 

off

2

Test
Subscriber
Circuits

a. Test each subscriber circuit by

placing and receiving calls.

ACTIVE 1 through 8 LEDs track call as described in
paragraph 7.01.

Note:

To reduce the power required by the Remote Terminal, the RT Channel Unit LEDs will extinguish after a two minute time
out. Press and hold the ACO button on the RT Line unit for two seconds to reactivate the LEDs for another two minutes.

Summary of Contents for PairGain PG-Flex FRC-753

Page 1: ...TURES 2 2 APPLICATIONS 2 3 SPECIFICATIONS 3 4 CERTIFICATION 4 5 WARRANTY 4 B FUNCTIONAL DESCRIPTION 6 OPERATIONAL CAPABILITIES 6 7 FRONT PANEL 6 C INSTALLATION AND TEST 8 UNPACKING 6 9 TURN UP AND TES...

Page 2: ...simplifies troubleshooting Pair Gain Test Controller PGTC Compatibility List 2 only 2 APPLICATIONS 2 01 Subscriber Drop Testing For subscriber drop testing from the central office PG Flex is able to...

Page 3: ...le loop resistance minus 430 ohms for handset is 530 ohms RT Idle State Loop Voltage On Hook Greater than 40 Vdc Ring is negative with respect to Tip RT Loop Closure Off Hook Detection Less than 960 o...

Page 4: ...the current edition of the National Electrical Code 5 WARRANTY 5 01 PairGain Technologies warrants this product to be free of defects and to be fully functional for a period of 5 years from the date o...

Page 5: ...Section 363 753 102 Revision 01 Page 5 Figure 3 FRC 753 Block Diagram...

Page 6: ...of the FRC 753 Channel Unit contains the following indicators see Figure 1 ACTIVE 1 8 LED Indicators Green the channel is off hook Flashing Green slow flash the channel is ringing the LED will track...

Page 7: ...to bottom then turn off b After the system has powered up established HDSL synchronized communications and no calls are in progress observe the Channel Unit front panel indicators ACTIVE 1 off ACTIVE...

Page 8: ...ts on the subscriber drop 2 If ringing isn t present on a circuit terminated on the same RT Channel Unit try ringing a line terminated on another RT Channel Unit If the line rings replace the RT Chann...

Reviews: