Mechanical & Environmental

 

Weight   

175g (6.17 oz) 

Dimensions (W × L × H) 

38 x120 x 33mm (1.5”x4.7”x1.3”) 

Operation Temperature 

-20°C ~ +60°C (-4°F ~ 140°F) 

Storage Temperature 

-30

C ~ 80

C (-22°F ~ 176°F) 

Humidity 

20% to 85% RH. (non-condensing) 

1. All EA-EOC101 factory default is paired to same network group, it can be installed directly, no 

need pairing again. 

2. The transmission system consists of one EA-EOC101 transceiver at NVR side and up to four 

EA-EOC101 transceivers that connect to IP cameras or other IP device. 

3.

 

Use two or more transmission systems at NVR side, and there are crosstalk problems on cables 

that between different transmissions systems, otherwise no need to do 

pairing

 process. 

4. To 

join

 another network group, must 

leave

 current group first, then do the group

 join

.

 

  Packing 

1. EA-EOC101 Transceiver 

×2 

2. BNC to Terminal Block Adaptor [

15-BT104]

  ×2 

3. User manual 

×1 

4. Wall Mount Kit 

×2     

5. Power Adaptor 

   

                ×2

 

[Option: DC 12V / 500mA]       

  PANEL DESCRIPTIONS: 

 

 

1. DC12V IN: Power Supply DC12V/500mA. 

2. ETHERNET: Ethernet Interface (10/100Mbps for full duplexer) 

3. ACT./LINK: Data Link for indication LED 

4. POWER: Power On for indication LED 

5. SIGNAL STRENGTH: G(Green):GOOD     

A(Amber):MEDIUM   

R(Red):BAD   

OFF

NO LINK 

Summary of Contents for EA-EOU101K

Page 1: ...ace Connector Type 1 x BNC with BNC to Terminal Block Adaptor 15 BT104 Cable Type The Straight through cable Cat 5e Cat 6 Max Transmission Distance 1000m 3300ft for the Cat 5e cable Ethernet Interface Connector Type 1x RJ 45 with LEDs on Connector Cable Type Straight through or cross over Cat5 Cable Auto MDI MDIX Rate IEEE 802 3x Auto Detection for 10 100Base T and full half duplex Control Indicat...

Page 2: ... device 3 Use two or more transmission systems at NVR side and there are crosstalk problems on cables that between different transmissions systems otherwise no need to do pairing process 4 To join another network group must leave current group first then do the group join Packing 1 EA EOC101 Transceiver 2 2 BNC to Terminal Block Adaptor 15 BT104 2 3 User manual 1 4 Wall Mount Kit 2 5 Power Adaptor...

Page 3: ...ock adaptor COP PN 15 BT104 CONNECTION DIAGRAM Notice The cable quality camera bandwidth requested and supply power noise will caused the distance which may not match as bellowi specification Application Diagram 1 Single Camera EoU Transmission System Application Diagram 2 Star Two Cameras EoU Transmission System Application Diagram 3 Star Three Cameras EoU Transmission System ...

Page 4: ...4 Application Diagram 4 Star Quadruple Cameras EoU Transmission System Application Diagram 5 Daisy Chained Quadruple Cameras EoU Transmission System ...

Page 5: ...de Transceiver Leaving Current Network Group On transceiver at Remote side close to IP camera device using the straightened paper clip to access the small push button for 5 8 seconds the color LED will begin AMBER blinking once then OFF Step 5 Slave Side Transceiver Joining New Network Group EOC EOU transceivers at Remote side close to IP camera device using the straightened paper clip to access t...

Reviews: