background image

 

Before do the pairing process, please check as bellow notice 

1)  If only setup one transmission system at NVR or control room side,

 

no need to do pairing 

process. 

2)  When using two or more transmission systems at NVR or control room side, if there are no 

cross-talk problems between different transmission systems, no need to do pairing 
process. 

 

EoC/EoU Transmission System Network Group Pairing Instructions 

Step 1: Setup EoC/EoU Transmission System 

 

Connect all the coaxial, cat. 5e cables between transceivers, setup cameras and NVR then 
power supplied to the system that one of the application diagrams. 

 

Step 2: Host/Master Side Leaving Current Network Group   

 

On transceiver at NVR side, using the straightened paper-clip to   

access the small push button for 

5 ~ 8 seconds

, the color LED will 

begin 

AMBER

 blinking once then 

OFF

 

Step 3: Host/Master Side Create an New Network Group 

 

On transceiver at NVR side, using the straightened paper-clip to access the small push 
button for 

1 ~ 3 seconds

, the color LED will begin 

RED

 blinking. 

 

Step 4: Slave Side Transceiver Leaving Current Network Group 

 

On transceiver at Remote side (close to IP camera/device), using the straightened paper-
clip to access the small push button for

 5 ~ 8 seconds

, the color LED will begin 

AMBER

 

blinking once then 

OFF

 

Step 5: Slave Side Transceiver Joining New Network Group 

 

EOC/EOU transceivers at Remote side (close to IP camera/device), using the straightened 
paper-clip to access the small push button for

 1 ~ 3 seconds

, the color LED will begin 

RED

 

blinking. The transceivers will find each other and starting the transmission. 

 

Step 6: Adding Additional Transceiver Joining New Network Group 

 

Repeat Step 4 and 5 to adding additional transceiver to new network group.   

 

In Pairing Process Notice 

1) 

In joining or leaving process, if you are not sure that joining or leaving has been 
successful, you can RESET the transceiver (press the push button 12 to 30 seconds) , 
and repeat above steps. 

2) 

After re-apply power or RESET transceiver, please wait color LED Amber blinking once 
then GREEN, its means power on reset finished and you can do the pairing process. 

3) 

The transceiver is from LEAVE to JOIN state (color LED RED blinking), it must join new 
network group in 2 minutes, otherwise it will become LEAVE state again.     

 

 

VER:20170224

 

 

 

Summary of Contents for EA-EOC101K

Page 1: ...01 Extender Interface Connector Type 1x BNC Cable Type 75 ohm RG59 RG6 or RG11 video grade coaxial cable Max Transmission Distance 2000m 6500ft for the RG6 coaxial cable Ethernet Interface Connector Type 1x RJ 45 with LEDs on Connector Cable Type Straight through or cross over Cat5 Cable Auto MDI MDIX Rate IEEE 802 3x Auto Detection for 10 100Base T and full half duplex Control Indicators Color LE...

Page 2: ...stems at NVR side and there are crosstalk problems on cables that between different transmissions systems otherwise no need to do pairing process 4 To join another network group must leave current group first then do the group join Packing 1 EA EOC101 Transceiver 2 2 User manual 1 3 Wall Mount Kit 2 4 Power Adaptor 2 Option DC 12V 500mA PANEL DESCRIPTIONS 1 DC12V IN Power Supply DC12V 500mA 2 ETHE...

Page 3: ...d supply power noise will caused the distance which may not match as bellow specification Application Diagram 1 Single Camera EoC Transmission System Application Diagram 2 Star Two Cameras EoC Transmission System Application Diagram 3 Star Three Cameras EoC Transmission System ...

Page 4: ...4 Application Diagram 4 Star Quadruple Cameras EoC Transmission System Application Diagram 4 Daisy Chained Quadruple Cameras EoC Transmission System ...

Page 5: ...de Transceiver Leaving Current Network Group On transceiver at Remote side close to IP camera device using the straightened paper clip to access the small push button for 5 8 seconds the color LED will begin AMBER blinking once then OFF Step 5 Slave Side Transceiver Joining New Network Group EOC EOU transceivers at Remote side close to IP camera device using the straightened paper clip to access t...

Reviews: