background image

2-5. Sensor connection

Connect sensors to D-SUB 25 Pin as specified below.

2-6. Network connection

RS-232C : Connected to RS-232C port of PC to operate DVR unit with key-board of PC.

8

Notice :TERATRAY CONNECTION port must be used for connecting HDD Bay (TeraTray), and can not be 
              used for connecting other device. Connection must be done while power supply to DVR unit is cut.

RS 485 : Connected to P/T Controller or Speed Dome Camera

You can connect dry-contact type sensors. In case of sensors with TTL output (5 Volts system), GND of 
sensor must be connected to GND of DVR unit and signal line to alarm input from D1 to D16 as shown in 
following figure.

Short-circuit between any of D1 from D16 and GND is recognized as an alarm.

Relay output is output in case there is an alarm input, and is connected to external 
device using COM-NO (Normal Open) or COM-NC (Normal Close) contact.

SENSOR

1

2

3

4

5

D1

D3

D2

D4

7

8

6

D5

D6

9

10

13

14

11

D7

D9

D8

D10

15

16

12

D11

D12

19

20

17

D13

D14

21

22

18

D15

D16

RJ-45 : Connected to LAN, WAN or Internet

2. Installation

GND

All GNDs are connected to each other on circuit.

4. MOTION SETUP

19

SYSTEM SETUP

CAMERA SETUP
TIME/DATE SETUP
RECORD SETUP
HDD MANAGEMENT
MISCELLANEOUS SETUP
TCP/IP SETUP
FACTORY DEFAULT

EDIT CAMERA TITLE
ADJUST COLOR
MOTION SETUP

SELECT : MENU     EDIT : ENTER/

↑↓ ←→

CELL

  ON

CAM 01
X08Y07

Motion detection menu

Channel in setting 
and coordinates 
of current cell

Current sell

Basic display : Press [MENU] button repeatedly until you find menu item to set, and select by
                        pressing [ENTER] button.
                        In basic display of MOTION SETUP, green colored cell represent motion detection area.

CELL
  ON(OFF)

Using direction keys, select cell to set and press [ENTER] button. Color of cell set is changed to green.

   Sets motion detection area and sensitivity of motion to be detected.

BLOCK ON
  BEGIN
  END

Sets motion detection area cell by cell.

Sets motion detection area by block(X x Y).

Using direction keys, select the first location of cell and press [ENTER] button, and then select the second location of 
cell using direction keys and again press [ENTER] button.
You will see color of all cells inside 2 coordinates is changed to green, motion detection area. 

ALL
  OFF(ON)

All cells are set as a detection area or no detection area.

When it is in ALL-OFF, press [ENTER] make all cells no detection area. When it is in ALL-ON, press
[ENTER] to make all cells detection area.

SENSITIVITY
  LEVEL   10

Sets sensitivity of motion detection.

Using [Up] and [Down] buttons, choose sensitivity level.  
                                                                      LEVEL 01 (Dull)                            LEVEL 10 (Sensitive)

DETECT WINDOW
NUMBER 01

Sets numbers of cells corresponding to size of motion.

Just in case numbers of cell detected (green colored) is more than set numbers, motion is detected.
If you set DETECT WINDOW NUMBER at bigger number, motion by small object is not detected.
Press [Up] and [Down] buttons to increase or decrease cell number.

3. Operation

Display of MOTION SETUP

Exit

To exit, press [ENTER] button.

When motion is detected, it is changed 
to green color and glittering.

When TeraTray is connected to DVR unit, supply power to TeraTray first and then to DVR unit.

TERATRAY CONNECTION

DC 12V

ETHERNET

C

o

m

m

P

o

r t

ALARM/ RELAY

RS-232C/485

rks

PTZ

CAMERA

PC

1

10

9

8

7

6

5

4

3

2

11

25

24

23

22

21

20

19

18

17

16

15

14

13

12

D1

D2

D3

D4

GND

GND

D5

D6

D7

D8

GND

GND

D9

D10

D11

D12

GND

GND

D13

D14

D15

D16

NO

COM

NC

RELAY Output

15-DVR16SAE-LAN

15-DVR16SAE-LAN

ALL ABOUT IMAGE RECOGNITION & PROCESSING

ALL ABOUT IMAGE RECOGNITION & PROCESSING

Summary of Contents for 15-DVR16SAE-LAN

Page 1: ...VR16SAE LAN 15 DVR16SAE LAN ALL ABOUT IMAGE RECOGNITION PROCESSING The most stable and reliable real stand alone Digital Video Recorder User Manual VER 1 0 Safety Security 16 Channel Digital Video Recorder ...

Page 2: ...4 Chap 4 Specification and Configuration 4 1 SPECIFICATIONS 25 4 2 Configuration 15 DVR16SAE LAN 26 4 3 RS 232C Hex code table 26 4 4 Arrange of RS 485 and RS 232C pin 26 26 2 Configuration of 15 DVR16SAE LAN 3 RS 232C ASCII code table Following ASCII code are for programmers who want to control DVR unit via RS 232C port RS 232C specification baud rate parity data length stop bit 57600 N 8 1 1 Byt...

Page 3: ...plication first turn the power OFF and follow manual instruction for 8 For questions and technical assistance of this product contact your local dealer appropriate installation 25 1 SPECIFICATIONS INPUT OUTPUT S N RATIO HORIZONTAL RESOLUTION COLOR DIGITAL ZOOM PICTURE IN PICTURE SEQUENCE DIAPLAY QUALITY RECORDING FRAME RATE HDD STORAGE CAPACITY COMPRESSED RECORDING MODE PLAY BACK SPLIT SCREEN BACK...

Page 4: ...T CMD SETUP BAUDRATE SETUP PASSWORD SETUP Display of FACTORY SETUP FACTORY SETUP ALL SETUP CAMERA COLOR CAMERA TITLE MOTION MASK PAN TILT COMMAND SYSTEM STATUS SYSTEM SETUP CAMERA SETUP TIME DATE SETUP RECORD SETUP HDD MANAGEMENT MISCELLANEOUS SETUP TCP IP SETUP FACTORY DEFAULT NO NO NO NO NO RUN You can set all groups of settings as a whole or set them group by group Move to menu items using Up a...

Page 5: ...rges pictures two times Possible to fix area to be enlarged using direction buttons 18 IR receiver If blocked up by any object remote controller does not work 19 Direction key Used to move in SETUP menu or to change values 4 Notice If several keys are pressed at the same time or improper sequence in pressing buttons may cause malfunction of DVR unit 2 LED Indicates the status of system 9 Record Re...

Page 6: ... CLOSE _ _ DISABLE SYSTEM SETUP CAMERA SETUP TIME DATE SETUP RECORD SETUP HDD MANAGEMENT MISCELLANEOUS SETUP TCP IP SETUP FACTORY DEFAULT BUZZER SETUP ALARM SETUP TIMER SETUP PAN TILT CMD SETUP BAUDRATE SETUP PASSWORD SETUP Set type of alarm sensors connected to DVR unit Set at NO Normal Open or NC Normal Close for alarm sensors Set at DISABLE or ENABLE for relay output Move to item you want to ch...

Page 7: ...R ON OFF BUZZER SETUP ALL BUZZER KEY BEEP LOSS EVENT ALARM EVENT MOTION EVENT _ _ _ ON OFF ON OFF 3 Operation Display of BUZZER SETUP Display of HDD MANAGEMENT HDD MANAGEMENT HDD CLEAR IN USE HDD INFORMATION HDD CLEAR ENTER PASSWORD _ _ _ _ _ _ _ _ _ INPUT YOUR OWN PASSWORD THEN PRESS ENTER TO EXIT PRESS MENU HDD INFORMATION DETECT DRIVE MODEL SERIAL SIZE DRIVE MODEL SERIAL SIZE DRIVE MODEL SERIAL...

Page 8: ...ssible to set from 1 1X to 1 999X If you set at 1 480X it corresponds to 960 hours recording mode in Time Lapse VCR e REFRESH RATE In Motion or Alarm recording mode DVR system records pictures at a certain time interval REFRESH RATE even though there is no motion detected or alarm activated 20 SEC Records pictures from all channels at time interval of 20 sec regardless of motion detected or alarm ...

Page 9: ...Using direction keys select cell to set and press ENTER button Color of cell set is changed to green Sets motion detection area and sensitivity of motion to be detected BLOCK ON BEGIN END Sets motion detection area cell by cell Sets motion detection area by block X x Y Using direction keys select the first location of cell and press ENTER button and then select the second location of cell using di...

Page 10: ... copy and move to the location to put it and press Playback to paste CAMERA COLOR SETUP CH NUMBER BRIGHTNESS CONTRAST SATURATION HUE GAIN Display of COLOR SETUP 1 1 3 0 1 14 3 ADJUST COLOR SYSTEM SETUP CAMERA SETUP TIME DATE SETUP RECORD SETUP HDD MANAGEMENT MISCELLANEOUS SETUP TCP IP SETUP FACTORY DEFAULT EDIT CAMERA TITLE ADJUST COLOR MOTION SETUP SELECT PRESS Adjust colors of images from camera...

Page 11: ...ws live display from ch 1 to 16 as following figure DVR system already started to record picture data automatically Chapter 3 Operation 10 3 Operation TIM 1 indicate current status of DVR Recording Recording stand by No motion or alarm detected in motion or alarm recording mode Stop Playback in forward direction Playback in backward direction x times high speed playback in forward direction x time...

Page 12: ...yback After pressing Pause button press Fast forward or Fast backward buttons to move forward or backward in the unit of field If you see pictures in 16 split screen you can move picture by picture in every channel whenever you press Fast forward or Fast backward button 7 Others a DVR system memorizes status of last playback For instance you searched recorded data in backward playback and stopped ...

Page 13: ...yback is stopped g If press Playback button playback starts again from the end of data in reverse direction h If press Stop button system goes to live display mode Unless you press RECORD button DVR system does not record 2 Example of operation a If press Playback button shortly DVR system starts to replay b If press Playback button once again direction of playback is reversed c If press Playback ...

Page 14: ...Example Record all images at set recording rate fields sec and overwrite when HDD is full 7 Record setting 1 Log in to SYSTEM SETUP 2 Mover to RECORD SETUP and enter 3 Using direction keys set as figure a b MOTION recording Recording when motion is detected MOTION DETECTION Example Just record for 30 seconds whenever motion is detected and stop recording when HDD is full RECORD SETUP RECORD TYPE O...

Reviews: