b. Connect the remaining sensor yellow wire to the black wire that connects to the 

Secondary light fixture. When using an OS310R, the Secondary light fixture will 

not automatically turn on

by motion.

c. Connect the sensor red wire to the black wire that goes to the Primary light fixture. When using an OS310R, the Primary light fixture 

will automatically turn ON 

by 

motion.

d. Connect the sensor white wire to the neutral wire (white) in the wallbox.
e. Connect the sensor blue wire to the red traveler wire in the wallbox
f. Connect the sensor green wire to the ground wire in the wallbox.
g. Install the sensor loosely using the mounting screws provided.

2. Remove the existing switch in the other 3-Way location.

a. Connect the two black wires together.
b. Connect the white wires together and also connect the white wires to the common terminal (usually a black screw or a marking such as COM or COMMON near 

the terminal) on the 3-Way switch. 

c. Connect the red wire to either of the other switch terminals. The other terminal on the 3-Way switch will not have a connection made to it.
d. Re-install the 3-Way switch and tighten securely.

3. Apply power and verify that the sensor works by pushing the ON/OFF button. The lights should turn ON and OFF. If the lights do not work, then 

turn the power OFF

and

swap the connections to the sensor black/yellow wire and the red wire. Refer to wiring DIAGRAM 2.
4. Apply power again and verify the sensor works by pushing the ON/OFF button to verify the lights turn ON and OFF. 
5. Turn power OFF and go to 

COMPLETING THE INSTALLATION.

COMPLETING THE INSTALLATION:

1. Secure sensor into the wall box using two mounting screws provided. Turn the circuit breaker ON. 
2. Allow the sensor to stabilize for 10 seconds. The sensor is now ready to detect motion.
3. Verify that Power in ON by pushing the ON/OFF button. Lights and LED should turn ON.
4. NOTE - The sensor time delay is factory preset (OS310R = 5 minutes; VS310R = 30 minutes).
5. If you want to change the time delay proceed as follows:

a. Remove the button from the sensor by pressing in the hooks on the button, and then lift up on the button as shown in Fig. 3.
b. Set the time delay using the dial on the right side by using a small Phillips screwdriver. Align the arrow on the dial to desired time delay.
c. To allow the installer to quickly confirm that the second is functioning properly the time delay can be set to TEST. This will set a time delay 
of 5 seconds, which allows quick feedback that the sensor is working properly.

6. Replace push button by sliding it upward into the slots in the front housing and push down until the button hook snaps into place.
7. Push the ON/OFF button to verify that the lights turn ON/OFF, and that the button operates freely.
8. Install the wallplate.

Daylight Sensing Adjustment (OS310R only):

• The Daylight sensing feature prevents lights from turning ON when the room is adequately illuminated by natural light.

• NOTE

- The factory setting for this adjustment is fully clockwise and permits motion detection to turn ON the lights regardless of the ambient light level in the room. 

If the Night Light is ON the daylight feature is disabled,

• Remove the ON/OFF pushbutton to access the light level adjustment (see Fig. 4). 
• This adjustment 

must be

made when the light level in the room is at the desired level for the lights to turn ON.

• From the clockwise position, turn the dial on the left counterclockwise using a small Phillips screwdriver until the Night Light turns ON. 
• Step away from the sensor to allow the device to calibrate to the normal light level in the room. Do not obstruct the natural light. The calibration process starts 

when the Night Light turns OFF, and will take approximatly 5 seconds. At the end of the calibration process the sensor will turn the lights ON.

• Replace the ON/OFF pushbutton.

TROUBLESHOOTING:

If you have a problem with your Motion Sensor, first follow this guide. If the problem persists, call the customer service hotline at 1-866-853-4293 between 8:00 A.M. and
6:00 P.M. EST weekdays.

SYMPTOM

POSSIBLE CAUSE

SOLUTION

Light does not automatically turn ON.

1. Circuit breaker or fuse is turned OFF. 

1. Turn circuit breaker ON. 

2. Bulb is defective. 

2. Replace light bulb.

3. Poor connection. 

3. Verify all wiring connections.

4. ON/OFF button not pushed. 

4. Press the ON/OFF button.

5. Control may be wired incorrectly.

5. Check wiring.

6. Daylight sensing prevents lights ON.

6. Re-adjust daylight sensing level.

7. Manual ON mode selected

7. Set device to Automatic  mode.

Light does not automatically turn OFF.

1. Motion is still present.

1. Make sure there is no motion during the time delay period. 

2. Time Delay has not expired. 

2. No action needed or shorten TIME DELAY.

3. Control may be wired incorrectly.

3. Check wiring.

4. Switch is being triggered by air vent or other heat source.

4. Move switch to the other switch location (if a 3-way), or 
determine the source triggering the switch, and alter the air 
flow. 

Light does not stay ON

1. Motion is not detected.

1. Create movement in front of the sensor for 5 seconds. 

2. TIME control is set for too short a delay.

2. Set switch TIME control to longer time period.

Remote switch does not work

1. Control may be wired incorrectly.

1. Check wiring.

COOPER WIRING DEVICES LIMITED 2 YEAR WARRANTY

Cooper Wiring Devices (CWD) warrants this device to be free of defects in materials and workmanship in normal use and service for a period of two years from date of
original purchase. THIS 

2

YEAR LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS, OR LIABILITIES, EXPRESSED OR IMPLIED (INCLUDING

ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT IS IN DURATION IN EXCESS OF 

2

YEARS FROM THE DATE OF 

ORIGINAL CONSUMER PURCHASE). NO AGENT, REPRESENTATIVE, OR EMPLOYEE OF CWD HAS AUTHORITY TO INCREASE OR ALTER THE OBLIGATIONS OF CWD
UNDER THIS WARRANTY.
To obtain warranty service for any properly installed CWD device that proves defective in normal use send the defective RF System prepaid and insured to Quality Con-
trol Dept., Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269; in Canada: Cooper Wiring Devices, 5925 McLaughlin Road, Mississauga, Ontario  L5R 1B8.
CWD will repair or replace the defective unit, at its option. CWD will not be responsible under this warranty if examination shows that the defective condition of the unit
was caused by misuse, abuse, improper installation, alteration, improper maintenance or repair of damage in shipment to CWD.
CWD SHALL HAVE NO RESPONSIBILITY FOR INSTALLATION OF THE RF SYSTEM, OR FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, OR ANY SPECIAL, INCIDENTAL,
CONTINGENT, OR CONSEQUENTIAL DAMAGES OF ANY KIND, RESULTING FROM DEFECTS IN THE RF SYSTEM OR FOR BREACH OF ANY EXPRESS OR IMPLIED 
WARRANTY ON THIS PRODUCT.

First Location

Second Location

3 traveler wires are required

DIAGRAM 2: SENSOR WITH SWITCH IN LOCATION WITH HOT WIRE

3-Way Switch

          OS310R or VS310R Sensor

Hot

Black

Hot

Black

Black

Ground

Green

3-Way

Blue

Neutral

Neutral

Neutral

Neutral

White

White

White

White

Light 

Fixture

Light Fixture

Black Traveler

Red Traveler

White Traveler

Yellow 

Output #2

Yellow 

Output #2

Red

Output #1 

1. PRESS TO 
RELEASE 
HOOK

FIGURE 3

2. LIFT UP 
BUTTON

LIGHT LEVEL

TE

ST

   

  5

       15 

   3

0

TIME DELAY

FIGURE 4

Reviews: