SPECIFICATIONS

• Single Pole and 3-Way (Primary Output Only).
• 8.3A (1000W) 120V AC 60 Hz.
• For Incandescent, Magnetic Low Voltage (MLV), Electronic Low Voltage (ELV), Fluorescent,

Compact Fluorescent, LED, Motors up to 1/6 HP.

• Includes Selectable and Dimmable Night Light.

NOTE

-

A Neutral Connection is required in the wallbox where the sensor will be installed.

DESCRIPTION

• This Sensor Wall Switch can replace a standard wall switch in any of the following applications:

• Single location – One single pole switch.
• Two location – One location is the sensor and the other location is a standard 3-Way switch.

The

3-Way switch will only control the lights on the primary output.

• Both

OS310R

and

VS310R

have two outputs for controlling two separate loads.

• The

OS310R

automatically turns on output #1 (Primary) when a person enters the room.

• The

VS310R

requires manual activation to turn ON the lights for either output #1 or #2.

• Both

OS310R

and

VS310R

will automatically turn OFF both lights after a user selectable time delay.

• OS310R incorporates the ability to detect when rooms are only occupied very briefly and shortens the
time delay in order to save energy.

OS310R

includes a light level adjustment for daylight to prevent motion from turning ON the lights if

the light level in the room is bright enough that lights are not needed.
• A green LED indicates the status of either load, acts as a locator light, and provides a momentary
flash to indicate that motion has been detected.

OPERATION INSTRUCTIONS
Auto ON Sensor – OS310R

• OS310R will turn on lights for Output #1 (Primary)

automatically

when a person enters the room

• OS310R will turn ON lights for Output #2 (Secondary)

manually

when its pushbutton is pressed.

• Lights for

both

outputs will turn OFF automatically when no motion is detected after a selectable

time delay.

• The selectable time delays are 5 seconds (Test Mode), 5 minutes (factory default), 15 minutes

and 30 minutes.

Manual ON Sensor – VS310R

• The VS310R must be turned ON

manually

with the ON/OFF button for each output.

Both

light outputs will turn OFF automatically when no motion is detected after a selectable time delay.

• The selectable time delays are 5 seconds (Test Mode), 5 minutes, 15 minutes and 30 minutes (factory default).
• When the lights have turned OFF due to a lack of motion, the lights will turn back ON automatically if motion is detected within 10 seconds.

Night Light

• Press the Night Light lens momentarily to turn the Night Light ON or OFF.
• When the Night Light is ON, press and hold the Night Light lens to dim the Night Light to the desired brightness. Release when the desired brightness level is

reached. Press and hold again to brighten.

• The OS310R can also operate as a Manual ON sensor when the Night Light is ON. Refer to OS310R Special Modes for additional explanation.

OS310R SPECIAL MODES

Reverse Mode:

The reverse mode is used when the lights must stay

OFF

in a room while motion is detected. If the lights are ON, a double tap of button 1 (Primary)

will turn off the lights and put the device into the Reverse Mode. This allows the lights to stay OFF as long as motion is detected. After a 5 minute delay the sensor
operation goes back to normal.

Manual ON Only mode:

This mode may be selected to prevent motion from automatically turning ON the lights. Press and hold the ON/OFF button for 5 seconds

until the indicator LED blinks. Release the button while the LED is blinking. Repeat this procedure to restore normal operation. While the

OS310R

is in the manual

ON mode, it will behave like a

VS310R.

Override Mode:

Turns OFF all motion sensing and allows the device to be used as a regular ON/OFF switch or in the unlikely event of a failure of the motion sensor.

Press and hold the ON/OFF button for 10 seconds until the indicator LED blinks for the second time (the LED will also blink at the 5 second point). Release
the button while the LED is blinking. Repeat this procedure to restore normal operation. This mode also can be used on

VS310R

.

Manual ON Mode with Night Light ON:

When in the auto ON mode, when the Night Light is turned on, the sensor will operate in the manual ON mode. This feature

can be enabled by pressing and holding the Night Light button for 5 seconds while the Night Light is OFF. The Night Light will blink after 5 seconds. Release the
button while the green LED is blinking. Repeat this procedure to restore normal operation.

INSTALLATION INSTRUCTIONS
WARNING::  

• 

Turn OFF circuit breaker or remove fuse(s) and verify that power is OFF before wiring. 

• Never wire any electrical device with power turned ON. Wiring the device with the power ON may cause permanent damage to the device and void the warranty.
• If you are unsure about any part of these instructions, or if the wiring does not match the descriptions given, you should call a qualified electrician.

CAUTION:

• Must be installed and used in accordance with all applicable electrical codes.
• If a bare copper or green ground connection is not available in the wallbox, contact a licensed electrician for installation. Do not install without a proper ground

connection.

• Do not exceed maximum device ratings.
• For use ONLY with permanently installed fixtures of these types: Incandescent/Halogen, Magnetic Low Voltage (MLV), Electronic Low Voltage (ELV), Fluorescent, 

Compact Fluorescent, LED.

• May also be used with motors up to 1/6 HP.
• To avoid overheating and possible damage to other equipment, do not use to control receptacles.
• Use only #14 or #12 copper wire with these devices.

Installing OS310R & VS310R

Refer to the wiring diagrams and install the sensor according to these directions. 

You must verify that a neutral wire is available in the wallbox.

For single pole applications

, wire the sensor switch according to wiring DIAGRAM 1 using the

wire nuts provided.

1. The sensor black wire and either of the yellow wires will connect to the hot wire (black) in
the wallbox. 
2. The other sensor yellow wire will connect to the wire which goes to the Secondary light 
fixture.
3. The sensor red wire will connect to the wire which goes to the Primary light fixture.
4. The sensor white wire will connect to the neutral wire (white) in the wallbox.
5. The sensor blue wire is not used and should be capped off with a wire nut.
6. The sensor green wire will connect to the ground wire in the wallbox.
7. Install the sensor loosely using the mounting screws provided.
8. Apply power temporarily and verify that the sensor works by pushing the ON/OFF button to 
verify the lights turn on and off. If the lights do not work, then turn off the power and swap the
connections on the sensor black and red wires
9. Apply power again and verify that the sensor works by pushing the ON/OFF button to verify the
lights turn on and off.
10. Turn power OFF and go to 

COMPLETING THE INSTALLATION.

For 3-Way applications

, wire the sensor switch according to wiring DIAGRAM 2 using the wire

nuts provided. The dual sensor 

must be placed 

at the end of the 3-Way circuit where the light

fixture wires are present in the wallbox.

1. Remove the existing switch in the location where the sensor will be installed. 

a. Connect the sensor black wire and either one of the yellow wires to the black traveler 

wire in the wallbox.

If you cannot determine which wire is the traveler wire, contact a 

licensed electrician.

Catalog # OS310R  Auto ON Sensor (Dual Output)   Catalog # VS310R  Manual ON Sensor (Dual Output)

DUALSWITCH-PTA (REV. A)

ENGLISH 

IIN

N  U

U..S

S..A

A..:: Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269 • 866-853-4293

0

15’

MAJOR MOTION

1000 SQ. FT.

36’

 0

COVERAGE PATTERN

MINOR MOTION

300 SQ. FT.

8’

15’

8’

15’

DIAGRAM 1: SENSOR IN ONE LOCATION

       OS310R or VS310R Sensor

Hot

(Black)

Hot

(Black)

Black

Ground

Green

Neutral

Neutral

White

Neutral

White

White

Primary Light

Fixture

Yellow 

Output #2

Yellow 

Output #2

Red 

Output #1 

Blue

3-Way

Secondary 

Light 

Fixture