INSTALLATION
Retrofit Kit Contents:
●
2 – End Plates (A)
●
1 – Side Panel (B)
●
1 – Lens (C)
●
1 – Main Panel (D)
Main P
anel
End x2
Side Panel
Lens
D
A
B
C
Risk of Fire, Electrical Shock- Retrofit kit installation requires knowledge of lighting luminaires’ electrical
systems. If not qualified, do not attempt installation. Contact a qualified electrician.
Risk of Fire or Electric Shock- Disconnect all power before installing retrofit kit.
Risk of Fire and Electric Shock- Luminaire’s wiring, ballast, or other electrical parts may be damaged during
installation of retrofit kit hardware. Check for enclosed wiring and components.
Risk of Fire or Electric Shock- Install this kit only in luminaires that have the construction features and
dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not
exceed the input rating of the luminaire.
Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing.
Risk of Personal Injury- Due to sharp edges, handle with care.
Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit
installation. Do not leave any other open holes in enclosure of wiring or electrical components.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or any sharp objects.
Failure to comply with these instructions may result in death, serious bodily injury and property damage.
WARNING
DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may
arise from the improper, careless, or negligent installation, handling or use of this product.
CAUTION:
Retrofit kit is used for 2’x4’ or 2’x2’ luminaires with min. housing depth of 3” (measured from inside top of
housing to T-grid).
IMPORTANT:
Read carefully before installing fixture. Retain for future reference.
NOTICE:
Fixture may become damaged and/or unstable if not installed properly.
Note:
Specifications and dimensions subject to change without notice.
ATTENTION Receiving Department:
Note actual fixture description of any shortage or noticeable damage on delivery
receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be filed within 15 days
of delivery. All damaged material, complete with original packing must be retained.
Installation Instructions – Cruze LED Retrofit Kit
Instructions d’installation – Cruze LED Retrofit Kit
Instrucciones de instalación – Del kit adaptador de luminaria
LED Cruze
NOTICE:
Fluorescent lamps contain Mercury. Dispose according to local, state, or federal laws.
IB519034EN
Metalux
Recommended Tools:
●
For optimum installation we
recommend using an 1800
RPM drill with a 1/4” Hex
Driver Bit.
●
Wire cutters/strippers.
●
Flat head screwdriver