![Cooper Tools Campbell E Operator'S Manual Download Page 15](http://html1.mh-extra.com/html/cooper-tools/campbell-e/campbell-e_operators-manual_2664755015.webp)
15
Clamp Specific Operating Instructions
(continued)
"Twin Lifter" Clamp
– used with drums between 17.5" and
25" (445 and 635 mm) in diameter
These clamps are to be used on
steel drums
only
, with the cams positioned on the outside of the drum.
Do not lift more than one drum per clamp.
1.
Press down on the shackle to retract the cam. Place clamp
squarely on drum to the full depth of throat opening.
Release shackle so that cam engages drum. You are now
ready to make the lift.
2.
To release drum, press down on the shackle and lift clamp
off drum.
"Hand Grips"
1.
Press down on handle or eye nut to retract cams. Place
clamp squarely on plate to the full depth of throat opening.
Release handle or eye nut so that cams engage plate. You
are now ready to make the lift.
2.
To release plate, press down on shackle or eye nut and lift
clamp off plate.
WARNING:
WARNING: