Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
44"
36"
26"
HIGH LUMEN CFL
1 2 0 0 O P T I C D R AW I N G S STA N DA R D
1200 - SINGLE STEM
AIRCRAFT CABLE (1SAC)
26"
2-3/8"
1200 - TRIPLE STEM (3S)
26"
2 3/8"
1200 - AIRCRAFT CABLE
WITH SJ CORD (SJAC)
26"
2-3/8"
1200 - SINGLE STEM (1S)
26"
2-3/8"
1200 - SUSPENSION OPTIONS STANDARD
Single Stem (1S):
5” stacked canopy with a 1-1/2”
swivel ball. One 5/8” stem with a standard hang
height of 24” (OA), minimum 18” (OA).
Maximum
overall hang height for one-piece stem assembly
is 8’ (OA) . For 8’ to 30’ (OA) the stems are supplied
in multiple sections. Solid Bottom only.
Triple Stem (3S):
5” stacked canopy with a 1-1/2”
swivel ball. One 5/8” stem with a standard hang
height of 24” (OA), minimum 18” (OA). Maximum
overall hang height for one-piece stem assembly
is 5’ (OA). For lengths from 5’ to 25’, a collector
body (CB) will be provided. Solid Bottom only.
Aircraft Cable with a SJ Cord (SJAC):
One
5/8” stem and 3/32“ cables with a standard hang
height of 24” (OA), minimum 18” (OA).
Single Stem Aircraft Cable (1SAC):
Three or four
3/8” stem with a standard hang height of 24” (OA),
minimum 18” (OA). Maximum overall hang height
is 8’ (OA). Contact factory for lengths above 8’.
Specify SCA for sloped ceilings up to 45°. Solid
Bottom only.
INSTALLATION
Contractor to provide appropriate structural support
for fixture weight. Refer to the installation drawings
for details. Integral safety cable provided.
SUSPENSION OPTIONS
1 2 0 0 - S U S P E N S I O N O P T I O N S STA N DA R D
1200 SERIES HP PENDANT
ADS051189
2008-09-08 13:25:49
4 9 4 - R P
4 4 4
4 9 4 - S
4 9 4
6 10
6 9 3
6 9 3 - S
C O M P A N I O N P R O D U C T S