  Problem

  

Cause / Solution

  Outdoor Lights
  Do Not Come
  On With Motion
  At Night

No power to the fixture.
  •  Check if circuit breaker tripped.
  •  Confirm wall switch is ON.
Bulb is faulty.
  • Replace bulb.
Surrounding external ambient light is too bright. (If so, the unit may

think it is daytime.)
  •  Re-aim the head.
  •  Relocate or reposition the unit away from the light.

TURN OFF POWER BEFORE CONTINUING

Wiring to the unit is loose.
  •  Check wiring, and reconnect if necessary using wire 

    nuts (E) provided.

  Outdoor Lights 
  Come On For No
  Apparent Reason
  At Night

There is motion in the detection zone.
  •  Make sure the sensor is not picking up moving objects such as

    trees, traffic, etc.

TEST FOR YOURSELF.

  •  Cover the sensor lens with cardboard to prevent sensor from 

    detecting motion. If the light stays off, something in the detection 

    zone is triggering the sensor.
    • If this is the case, reduce the sensitivity.
  * If the light stays on with the sensor lens covered, contact 

  customer service.
Unit is in the AUTO mode.
  •  Make sure the unit is not in one of the three 

    “Night Time On” modes.

  Lights Stay On At
  Night And Do 
  Not Turn Off

There is motion in the detection zone.
  •  Make sure the sensor is not picking up moving objects such as

    trees, traffic, etc.
  •  Reduce the sensitivity.
  •  Reposition the sensor.
Unit is in override mode (if there is no motion).
  •  Turn the light switch to the OFF position for 90 seconds, and then

    turn back to the ON position. This will send the unit back into

    the AUTO mode.
    * If the lights continue to stay on, contact customer service.
Unit is in the AUTO mode.
  •  Make sure the unit is not in one of the three 

    “Night Time On” modes.

  Cannot Activate
  Dusk to Dawn
  Mode at Night
  (Override)
 

Surrounding external ambient light is too bright. (If so, the unit may

think it is daytime.)
  •  Re-aim the head.
  •  Relocate or reposition the unit away from the light.
Not enough time is allowed to enter the dusk to dawn mode.
  •  Turn the light switch to the OFF position for 5 seconds, and 
    then back to the ON position.
There is more than one fixture on an indoor wall switch.
  •  If so, put them on separate switches.

TROUBLESHOOTING

2-YEAR LIMITED WARRANTY

THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, 

WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT LIMITED TO, ANY 

WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
Cooper Lighting, LLC (“Cooper Lighting”) warrants to customers that, for a period of two years 

from the date of purchase, Cooper Lighting’s products will be free from defects in materials 

and workmanship. The obligation of Cooper Lighting under this warranty is expressly limited 

to the provision of replacement products. This warranty is extended only to the original 

purchaser of the product. A purchaser’s receipt or other proof of date of original purchase 

acceptable to Cooper Lighting. This is required before warranty performance shall be rendered.
This warranty does not apply to Cooper Lighting products that have been altered or repaired 

or that have been subjected to neglect, abuse, misuse or accident (including shipping damages). 

This warranty does not apply to products not manufactured by Cooper Lighting which have been 

supplied, installed, and/or used in conjunction with Cooper Lighting products. Damage to the 

product caused by replacement bulbs or corrosion or discoloration of brass components are 

not covered by this warranty. 
LIMITATION OF LIABILITY:

IN NO EVENT SHALL COOPER LIGHTING BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR 

CONSEQUENTIAL DAMAGES (REGARDLESS OF THE FORM OF ACTION, WHETHER IN CONTRACT, 

STRICT LIABILITY, OR IN TORT INCLUDING NEGLIGENCE), NOR FOR LOST PROFITS; NOR SHALL 

THE LIABILITY OF COOPER LIGHTING FOR ANY CLAIMS OR DAMAGE ARISING OUT OF OR 

CONNECTED WITH THESE TERMS OR THE MANUFACTURE, SALE, DELIVERY, USE, MAINTENANCE, 

REPAIR OR MODIFICATION OF COOPER LIGHTING PRODUCTS, OR SUPPLY OF ANY REPLACEMENT 

PARTS THEREFORE, EXCEED THE PURCHASE PRICE OF COOPER LIGHTING PRODUCTS GIVING RISE 

TO A CLAIM. NO LABOR CHARGES WILL BE ACCEPTED TO REMOVE OR INSTALL FIXTURES. 
To obtain warranty service, please contact Cooper Lighting, LLC, at 1-800-334-6871, press 

option 2 for Customer Service, or via e-mail [email protected] and 

include the following information:

• Name, address and telephone number

• Date and place of purchase

• Catalog and quantity purchase

• Detailed description of problem
All returned products must be accompanied by a Return Goods Authorization Number issued 

by the Company and must be returned freight prepaid. Any product received without a Return 

Goods Authorization Number from the Company will be refused.
Cooper Lighting, LLC is not responsible for merchandise damaged in transit. Repaired or 

replaced products shall be subject to the terms of this warranty and are inspected when

packed. Evident or concealed damage that is made in transit should be reported at once to 

the carrier making the delivery and a claim filed with them.  

Reproductions of this document without prior written approval of Cooper Lighting, LLC are strictly prohibited.

For assistance, call 1-800-334-6871 or e-mail us at [email protected]

Printed in China

ARTÍCULOS NECESARIOS

(se compran por separado)

•  Destornillador en cruz (Phillips)
•  Calafateo de silicona resistente a la intemperie
•  (2) lámparas para proyector tipo PAR 38 de 100 W (máximo)

NOTA:

 Este accesorio fue diseñado para trabajar con bombillas reflectoras de Halógeno PAR 

de 150 vatios como máximo. Para mayor eficiencia de energía, use bombillas reflectoras 

Halógeno PAR de menor vataje. No se recomienda el uso de bombillas fluorescentes   

compactas (CFL) porque tienen partes electrónicas que pueden interferir con las funciones  

de detección de movimiento de su accesorio. Para cumplir con los requerimientos de  

ENERGY STAR

®

, la potencia máxima de la bombilla no debe exceder 250 W.

  Lights
  Continuously
  Blink On and
  Off At Night

The light given from the unit’s own lamp is affecting the 

motion sensor.
  •  Re-aim the lamp.
  •  Reposition motion sensor.

  Lights Are On 
  During The Day

The controls on the bottom of the motion sensor are in the test mode.
  •  Move the switch to the AUTO 4, AUTO 12 or Night Time On 

    position.
The motion detector is shadowed.
  •  Reposition motion sensor.

  Problem

  

Cause / Solution

  Lights Do Not
  Come On In 
  Night Time On
  Mode

The sensor is not in the correct setting.
  •  Move slide switch to 2 Hr, 4 Hr, or 6 Hr setting.

  Lights Will Not
  Respond To
  Selected 
  Night Time On
  Setting

Night Time On setting was changed after lights were already ON in 

a different Night Time On setting.
  •  Night Time On setting cannot be changed until the next dawn 
    once light is operating in that setting. See “Selecting Your 
    Desired Feature”.
If lights do not come on at all in Night Time On mode:
Surrounding external ambient light is too bright. (If so, the unit may

think it is daytime.)
  •  Re-aim the head.
  •  Relocate or reposition the unit away from the light.

 