ORDERING INFORMATION

PHOTOMETRICS

SHIPPING INFORMATION

AC

S A M P L E   N U M B E R : AC - 1 2 8 T 5 - U N V- E B T 1 N D I M

Number of Lamps

(Not included)

1=1 Lamp

Wattage (Length)
28T5
=28W T5 (48")
54T5=54W T5HO (48")

Voltage

(1)

UNV=Universal Voltage

120-277

Options
GL
=Single Element Fuse
GM=Double Element Fuse
Flex=Flex installed
EL=Emergency Installed

Packaging
U
=Unit Pack

PALC=Job Pack,

in carton

Shielding

Blank=Frosted Acrylic

(standard)

Ballast Type
EBT                                 
=T5 Linear Electronic

Program Rapid Start 

Total Harmonic 

Distortion < 10%

Ballast Factor/Type

(For 28W T5 Lamp Only)

N=Normal Light Output .95 BF

(2)

H=High Light Output 1.15 BF

(2), (4)

NDIM=Normal .95-1.0 BF Step Dimming

(3)

HDIM=High 1.15 BF Step Dimming

(3), (4)

NOTES:

(1)

Products also available in non-US voltages and frequencies for international markets. 

(2)

.95 and 1.15 ballast factor available for 28W T5 lamps only. 

(3)

Step Dimming ballast available for 28W T5 lamps only.

(4)

1-Lamp ballast in the High Ballast factor not available. 2-Lamp ballast will not operate 1-Lamp.

(5)

1' x 4' Accord is not designed for continuous row mount applications. For complete product data, reference the

Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.

No. of Ballast

1 or 2

Lamps

L5835=T5 Lamp,

3500K

L5841=T5 Lamp,

4100K

L5835HL=T5

Lamp, 28W,

3500K, 2900

Lumens

L5841HL=T5

Lamp, 28W,

4100K, 2900

Lumens

Series

AC=Accord Series

Width

(5)

Blank=1' Width

Rating

Blank=

Standard

NY=New York

Rated

ATW-SW4=

Chicago

Rated

C o e ffi c i e n t s o f U t i l i z a t i o n

Effective floor cavity reflectance

20%

rc

80%

70%

50%

30%

10%

0%

rw

70 50 30 10

70 50 30 10

50 30 10

50 30 10

50 30 10

0

RCR

0
1
2
3
4
5
6
7
8
9

10

L u m i n a n c e Da t a

Average

Average

Average

Angle

0-Deg

45-Deg

90-Deg

in Deg

cd/sm

cd/sm

cd/sm

45

1768

2084

2285

55

1659

2119

2395

65

1501

2125

2125

75

1195

1600

1382

85

555

463

339

Z o n a l L u m e n S u m m a r y

Zone

Lumens

%Lamp

%Fixture

0-30
0-40
0-60
0-90
0-180

||

C a n d l e p owe r

Angle

Along

II

45°

Across

0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90

AC-128T5

Electronic Ballast
F28T5/835 Lamps
2600 Lumens
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 1.4 x
mounting height
Efficiency 87.4%
Test Report:
241P113
LER = FL62
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.88

738

738

738

734

736

736

723

730

732

705

718

725

679

701

715

647

679

702

609

654

685

565

623

663

517

588

635

465

548

601

411

502

559

354

452

511

295

396

443

236

334

334

175

248

221

115

154

133

60

75

63

18

15

11

0

1

1

104 104 104 104

102 102 102 102

97 97 97

93 93 93

89 89 89

87

95 91 87 84

93 89 86 83

85 82 80

82 80 77

79 77 75

73

86 79 73 68

84 77 72 67

74 70 66

71 68 64

69 66 63

61

78 69 62 56

76 68 49 56

65 59 55

63 58 54

60 56 53

52

72 61 53 47

70 60 43 47

58 51 46

56 50 46

54 49 45

43

66 54 46 40

64 53 38 40

51 45 40

50 44 39

48 43 39

37

61 49 41 35

59 48 34 35

46 40 35

45 39 34

43 38 34

32

56 44 36 31

55 43 31 31

42 35 30

41 35 30

40 34 30

28

52 40 33 27

51 40 28 27

38 32 27

37 31 27

36 31 27

25

49 37 29 25

47 36 25 24

35 29 24

34 28 24

33 28 24

22

46 34 27 22

44 33 23 22

33 26 22

32 26 22

31 26 22

20

585

22.5

25.8

973

37.4

42.8

1788

68.8

78.7

2271

87.4

100.0

2271

87.4

100.0

Reviews: