Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
08/12/2008 2:37:31 PM
Specifications and Dimensions subject to change without notice.
ADF051799
ORDERING INFORMATION
PHOTOMETRICS
SHIPPING INFORMATION
AC
S A M P L E N U M B E R : AC - 1 2 8 T 5 - U N V- E B T 1 N D I M
Number of Lamps
(Not included)
1=1 Lamp
Wattage (Length)
28T5=28W T5 (48")
54T5=54W T5HO (48")
Voltage
(1)
UNV=Universal Voltage
120-277
Options
GL=Single Element Fuse
GM=Double Element Fuse
Flex=Flex installed
EL=Emergency Installed
Packaging
U=Unit Pack
PALC=Job Pack,
in carton
Shielding
Blank=Frosted Acrylic
(standard)
Ballast Type
EBT =T5 Linear Electronic
Program Rapid Start
Total Harmonic
Distortion < 10%
Ballast Factor/Type
(For 28W T5 Lamp Only)
N=Normal Light Output .95 BF
(2)
H=High Light Output 1.15 BF
(2), (4)
NDIM=Normal .95-1.0 BF Step Dimming
(3)
HDIM=High 1.15 BF Step Dimming
(3), (4)
NOTES:
(1)
Products also available in non-US voltages and frequencies for international markets.
(2)
.95 and 1.15 ballast factor available for 28W T5 lamps only.
(3)
Step Dimming ballast available for 28W T5 lamps only.
(4)
1-Lamp ballast in the High Ballast factor not available. 2-Lamp ballast will not operate 1-Lamp.
(5)
1' x 4' Accord is not designed for continuous row mount applications. For complete product data, reference the
Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
No. of Ballast
1 or 2
Lamps
L5835=T5 Lamp,
3500K
L5841=T5 Lamp,
4100K
L5835HL=T5
Lamp, 28W,
3500K, 2900
Lumens
L5841HL=T5
Lamp, 28W,
4100K, 2900
Lumens
Series
AC=Accord Series
Width
(5)
Blank=1' Width
Rating
Blank=
Standard
NY=New York
Rated
ATW-SW4=
Chicago
Rated
C o e ffi c i e n t s o f U t i l i z a t i o n
Effective floor cavity reflectance
20%
rc
80%
70%
50%
30%
10%
0%
rw
70 50 30 10
70 50 30 10
50 30 10
50 30 10
50 30 10
0
RCR
0
1
2
3
4
5
6
7
8
9
10
L u m i n a n c e Da t a
Average
Average
Average
Angle
0-Deg
45-Deg
90-Deg
in Deg
cd/sm
cd/sm
cd/sm
45
1768
2084
2285
55
1659
2119
2395
65
1501
2125
2125
75
1195
1600
1382
85
555
463
339
Z o n a l L u m e n S u m m a r y
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
0-60
0-90
0-180
||
C a n d l e p owe r
Angle
Along
II
45°
Across
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
AC-128T5
Electronic Ballast
F28T5/835 Lamps
2600 Lumens
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 1.4 x
mounting height
Efficiency 87.4%
Test Report:
241P113
LER = FL62
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.88
738
738
738
734
736
736
723
730
732
705
718
725
679
701
715
647
679
702
609
654
685
565
623
663
517
588
635
465
548
601
411
502
559
354
452
511
295
396
443
236
334
334
175
248
221
115
154
133
60
75
63
18
15
11
0
1
1
104 104 104 104
102 102 102 102
97 97 97
93 93 93
89 89 89
87
95 91 87 84
93 89 86 83
85 82 80
82 80 77
79 77 75
73
86 79 73 68
84 77 72 67
74 70 66
71 68 64
69 66 63
61
78 69 62 56
76 68 49 56
65 59 55
63 58 54
60 56 53
52
72 61 53 47
70 60 43 47
58 51 46
56 50 46
54 49 45
43
66 54 46 40
64 53 38 40
51 45 40
50 44 39
48 43 39
37
61 49 41 35
59 48 34 35
46 40 35
45 39 34
43 38 34
32
56 44 36 31
55 43 31 31
42 35 30
41 35 30
40 34 30
28
52 40 33 27
51 40 28 27
38 32 27
37 31 27
36 31 27
25
49 37 29 25
47 36 25 24
35 29 24
34 28 24
33 28 24
22
46 34 27 22
44 33 23 22
33 26 22
32 26 22
31 26 22
20
585
22.5
25.8
973
37.4
42.8
1788
68.8
78.7
2271
87.4
100.0
2271
87.4
100.0