background image

Tools Required

Socket, 5/16" Socket, 3/4" Deep Well Socket, Electrical

wiring tools.

NOTE: 

These luminaires are designed for outdoor lighting 

services, and should not be used in area of limited ventilation 
or in high ambient temperature enclosures. Construction is 
suitable for down lighting only. Best results will be obtained 
if installed and maintained according to the following 
recommendations.

1. 

Remove housing assembly and arm components from carton. Remove
power tray if fixture is not hard mount version. 

2. 

With the fixture on its back, open and remove door by pressing thumb
latches outward at the same time, open the door and lift it from the
hinges. 

FIG. 1

3. 

Run the threaded rods (2) through the center of the semi-enclosed hole
details in the arm extrusion. To help orient the arm correctly with the
housing, please note that one end of the extruded arm has an angled cut
and the other has a perpendicular cut with two drain notches located on
the bottom. If assembling to a round pole, use the round pole adapter
with the drain channels located at the extruded arm end with the drain
slots. Mate the angled side of the extruded arm to the housing so that
the bottom surface of the extrusion is parallel to the bottom of the 
fixture, and the drain notches are facing down and located away from
the housing. 

FIG. 2

Slide the threaded rods into the interior of the 

housing. Attach flat washer, lock washer, and nut into place in the order
shown in 

FIG. 2

. Torque hex nuts to 450 lb/in.

4. 

If necessary, remove the cap on the pole. Position the housing and arm
to assemble it to the pole. Lower the nut plate into the interior of the
pole as shown. Slide the threaded rods through the pole and thread into
the nut plate until the rod protrudes though the nut plate slightly. Tighten
both nuts located inside of the housing to 30 lb/ft of torque.

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency 
during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest 
representative.

Talon Medium

Sheet 1 of 3

11/29/07

IMI-687

INSTALLATION INSTRUCTIONS

IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE. 

WARNING

: Risk of Fire/Electric Shock. If not qualified, consult an electrician.

WARNING

: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing.

WARNING

: Risk of Burn. Disconnect power and allow fixture to cool before changing bulb or handling fixture.

WARNING

: Risk of Personal Injury. Fixture may become damaged and/or unstable if not installed properly. Tighten all fixture components 

to their recommended torque values.

WARNING

: Risk of Fire/Electrical Shock. Upside down installation can result in overheating or accumulation of water in fixture. 

Install right side up.

NOTE: Specifications and dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com

Customer First Center  1121 Highway 74 South  Peachtree City, GA  30269  770.486.4800  FAX  770.486.4801    

ADH071363

FIG. 1

Latches

FIG. 2

Hardware: Washer, 
Lock Washer, and 
Hex Nut

Arm

Nut Plate
Fits Inside 
of Pole

Round Pole
Adapter
(Optional)

Mounting Rod (2)