background image

ACCESSORIES: LOW VOL

T

AGE CABLE & TRANSFORMERS

1080

LUMIERE

®

COOPER LIGHTING

`

D E S C R I P T I O N

Transformers reduce line voltage to 12 volts for use with Lumière low voltage fixtures. 

O R D E R I N G   I N F O R M A T I O N

SAMPLE NUMBER:  TR900T

Order transformers and low voltage cable as separate line items.

Transformer Selection

The total wattage of all lamps used must not exceed the rating of the

transformer selected for the installation. For example, a 150VA (VA = watts)

transformer cannot power four fixtures with 50 watt lamps. 

The transformer selected should match the total lamp wattage as

closely as possible. It is good practice to use at least 33 to 50 percent,

and no more than 85 to 90 percent, of the transformer’s rated capacity.

Make sure that the transformer selected reduces the  appropriate line

voltage. For example, do not use a 120 to 12 volt transformer with a

277 volt system. Lumière Atlantis series fixtures (model 1407 - 1409)

must be used with model T300, which is approved for use in pool

and spa type applications.

Transformers must be installed in accordance with local and national

electrical codes and other rules, regulations and requirements.

Voltage Drop

Resistance to electricity passing through electrical wiring causes the

voltage at the end of a run of wire to be lower than the voltage at the

transformer. This will cause fixtures at the end of a run to be noticeably

dimmer than those closer to the transformer.

The factors affecting voltage drop are the total wattage of lamps on the

run, the length of the run and the gauge of the wire.

There are several ways to minimize the impact of voltage drop:

• Use larger gauge cable

• Shorten cable runs

• Use lower wattage lamps

• Reduce the number of fixtures on the run

• Divide the fixtures over more runs from the transformer

• Use multiple transformers

Voltage drop is not always bad.

For example, dropping voltage at the lamp to 11.5 volts will give

80% of the lamp's rated candlepower, and double the rated life of

the lamp. This is acceptable in most applications, and will result in

lower maintenance costs.

The accompanying chart demonstrates how voltage at the lamp

affects rated lamp life and rated candlepower:

Sample Landscape Lighting Installation

We recommend using 12/2 or larger inground stranded cable. To control

voltage drop, for each 100 watts allowed, use 100 feet of wire, maximum,

to stay at approximately 10 volts at the end of the run. For example, a 300

watt (300VA) transformer may have three separate runs with 100'

maximum on each run. This is standard procedure for low voltage

installations. Any setup within these parameters will maintain sufficient

lumen output. (Provided as an example only — output requirements

may vary depending on individual situations and preferences.)

VOLTAGE DROP FORMULA

Transformers are available in four basic types:

• Hard wire installation – Standard outdoor low voltage lighting transformer for hard wiring direct to conduit.

• Cord and plug – Plug in directly to existing outlets, for ease of installation. Also available with a built in timer.

• Inground – Low profile inground installation for reduced visual impact and increased flexibility.

• Compact solid state electronic transformers – For use in approved housings or boxes.

Total watts on cable x length of run

Cable size constant

*

= Voltage Drop

CABLE SIZE CONSTANT CHART

*

Cable size

#18

#16

#14

#12

#10

#8

#6

Cable constant

1380

2200

3500

7500

11,920

18,960

30,150

VOLTAGE DROP CHART

Voltage at lamp

13.2

12.6

12.0

11.5

11.0

10.5

10.0

Life expectancy of lamp

2/3 rated life

3/4 rated life

as rated

2X rated life

3X rated life

5X rated life

9X rated life 

% of rated candlepower

350

180

100

80

74

65

50