background image

Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

04/30/2007 8:47:23 AM

Specifications and Dimensions subject to change without notice.

ADC041425

PHOTOMETRICS

ORDERING INFORMATION

ORDERING MATRIX

11" ROUND

TC/TW

0

o

30

o

60

o

90

o

Zone        Lumens          %Lamp        %Fixture

0-  30

136

7.6

15.9

0-  40

245

13.6

28.6

0-  60

535

29.7

62.7

0-  90

839

46.6

98.2

0-180

854

47.5

100.0

0
1
2
3
4
5
6
7
8
9

10

CTTC-PP-26A-120

(1) PL-T/26W/30/4P Lamp

1800 Lumens 

Efficiency: 47.5%

Spacing Criterion: 1.7  

Ballast Factor:  1.0

Report # 767200

Zonal Lumen Summary

56  56  56  56      55  55  55  55       52  52  52          50  50  50           48  48  48            47    
50  48  45  43      49  46  44  42       42  42  41          42  41  39           40  39  38            37
45  41  37  34      44  40  36  33       38  35  32          36  33  31           34  32  30            29
41  35  30  27      39  34  30  26       32  29  26          31  28  25           29  27  25            24
37  30  26  22      36  30  25  22       28  25  22          27  24  21           26  23  21            20
33  27  22  18      32  26  22  18       25  21  18          24  20  18           23  20  17            16
30  23  19  15      29  23  18  15       22  18  15          21  17  15           20  17  14            13
28  21  16  13      27  20  16  13       19  15  12          18  15  12           18  15  12            11
26  18  14  11      25  18  14  11       17  13  11          17  13  11           16  13  10              9
24  17  12  9      23  16  12    9       16  12    9          15  12    9           14  11    9              8
22  15  11    8      21  15  11    8       14  10    8          14  10    8           13  10    8              7

Angle

0.0

0

151

5

152

10

153

15

157

20

161

25

165

30

169

35

173

40

175

45

177

50

176

55

171

60

163

65

148

70

127

75

101

80

71

85

46

90

27

Candlepower

Coefficients of Utilization

Effective floor cavity reflectance           20%

rc               80%                       70%                 50%                   30%                   10%                0%

rw      70  50  30  10     70  50  30  10       50  30  10           50  30  10           50 30  10             0

RCR

Notes: 
For additional options, consult your Cooper Lighting Representative. Specifications and dimensions subject to change without notice.

Products also available in non-US voltages and 50Hz for international markets.

1. Supplied from factory with deep casting. 2. Only available in HPF. 3. RP option not required when casting in supplied. 

*-Does not apply when using electronic ballast.

Reviews: