FAIL-SAFE
®
ARCHITECTURAL V
ANDAL RESIST
ANT
COOPER LIGHTING
D E S C R I P T I O N
The Fail-Safe VRGC and 2VRGC
Series fluorescent luminaires
feature recessed aesthetics and
the latest in energy-efficient
technology. Their Energy
Saving Ballast complies with
Federal Energy Standards.
Features include a die-
embossed housing, four
convenient end suspension
points, and high comfort
photometrics. U.L. listed and
C.S.A. certified.
• Nominal 41/2" deep
paracontoured housing,
die formed code gauge,
prime cold rolled steel
• Finish is lighting grade
baked white enamel
• Die formed, heavy gauge,
flat steel door with
reinforced mitered corners
and baked white enamel
finish. Positive light seals.
Frame and lens are secured
to housing with 4 or 6
stainless steel TORX
®
screws
• Positive cam action spring
loaded steel latches with
baked white enamel finish
• Ballasts are CBM/ETL Class
"P" and positively secured
by mounting bolts.
Pressure lock lampholders
VRGC
2VRGC
1 ' x 4 ' , 2 ' x 2 ' , 2 ' x 4 '
1 , 2 , 3 , O R 4 L A M P
V A N D A L R E S I S T A N T
L U M I N A I R E
M O U N T I N G
A
B
C
C
B
B
A
B
C
VRGC
5 5/8"
11 3/4"
48"
(1' x 4')
(143mm)
(298mm)
(1219mm)
2VRGC
4 5/8"
23 3/4"
24"
(2' x 2')
(117mm)
(603mm)
(610mm)
2VRGC
4 5/8"
23 3/4”
48"
(2' x 4')
(117mm)
(603mm)
(1219mm)
D I M E N S I O N S
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : 2 V R G C - 2 3 2 A - 1 2 0 V - E B 8 1 - U
Options
(order as suffix)
PAF
=Painted After
Fabrication
GL
=Internal Single
Element Fusing
GM
=Dual Element
Fusing
LCWE
=F40/Cool White
Energy Saving Lamps,
Installed
L8730
=F32T8 3000
Kelvin Lamps, Installed
L8735
=F32T8 3500
Kelvin Lamps, Installed
L8741
=F32T8 4100
Kelvin Lamps, Installed
EL4
=Emergency
Lighting self-contained
1
RIF1
=Radio Interference
Suppressor
FR
=Suitable for Fire
Rated Applications
EQ
=T-BAR Safety
Earthquake Clips
3
RLS
=Rotor-Lock Socket
(T8 Lamps Only)
6S
=Six TORX-head
Screws(3 per side)
SC
=Safety Chain
Number of Lamps
1
,
2
,
3
, or
4
lamps
(Not included)
Wattage (Length)
U3
=40W (24")
U6
=40W (24")
U6T8
=31W (24")
20
=20W (24")
17
=17W (24")
U1-5/8
=31W
T8 (24")
BX40
=40W
Biax (24")
40
=40W (48")
32
=32W T8 (48")
Series
C
Trim Type
1
G
=Grid/Lay-in – Standard
G
=Concealed T
G
=Slot Grid
F
=Flange Trim
MZ
=Modular Trim
EMZ
=Modular Trim (Extended
Swing Arm)
Door Type
Standard
=Flat White Steel Door
(Leave Blank)
Voltage
1
120
=120V
277
=277V
347
=347V
UNV
=
Universal
Voltage
120-277V
Voltage
LTS
=Low
Trigger Start
(20 Watt)
HTS
=High
Trigger Start
(20 Watt)
Ballast Type
Standard Magnetic Ballast
Leave Blank (Biax Only)
LE3
=
Energy Saving Ballast
LEOC8
= Energy Saving Ballast
(T-8 Lamp Only)
EB _ _
= Generic Electronic
Ballast
No. of Ballasts
1
or
2
2
Lamp Size
2
=T12
8
=T8
(For Specific Electronic Ballast
Specify Brand and Catalog
Number)
Lens Type
ACTF140
= .140 Thick
ACTF187
= .187 Thick
PA375
= .250 polycarbonate
with .125 prismatic
overlay
(standard with 6S
option)
Product Family
VR
Width
Blank=
1'
2
=2'
N O T E :
For additional options, consult your Cooper Lighting Representative. Specifications and Dimensions subject to change without notice.
1
Consult Pre Sales Technical Support.
2
Two ballast in 2 or 4 lamp require LAO (less access opening).
3
EQ Grid Clip is recommended for all 9/16"
ceiling systems.
1430