Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
08/02/2008 3:00:44 PM
Specifications and Dimensions subject to change without notice.
ADF042290
PI OPTION ORDERING INFORMATION
BLK=Black Hot
PI1= Single
Circuit
NG= No Ground (ground
provided by fixture body)
WG= With Ground
(separate ground wire
in harness)
P I 1 - S i n g l e C i r c u i t P l u g - I n
S A M P L E N U M B E R : P I 1 B L K - W G
BLK=Black Hot
BLU=Blue Hot
PI2= Two
Circuit
NG= No Ground (ground
provided by fixture body)
WG= With Ground (separate
ground wire in harness)
P I 2 - T w o C i r c u i t P l u g - I n
S A M P L E N U M B E R : P I 2 B L K - W G
Leave Blank=Single
Neutral
/WHT=White Neutral
/GRY=Gray Neutral
Leave Blank=Single
Neutral
2NEU=Two Neutrals
BLK=Black Hot
BLU=Blue Hot
RED=Red Hot
PI3= Three
Circuit
NG= No Ground (ground
provided by fixture body)
WG= With Ground (separate
ground wire in harness)
P I 3 - T h r e e C i r c u i t P l u g - I n
S A M P L E N U M B E R : P I 3 B L K - W G
Leave Blank=Single
Neutral
/WHT=White Neutral
/GRY=Gray Neutral
Leave Blank=Single Neutral
2NEU=Two Neutrals
For complete product data, reference the Fluorescent
Specification binder. Specifications & dimensions subject
to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.
Catalog
Circuit
Number
Number of
Wired To
Suffix
Circuits
Ballast
PI 1 BLK
1
Black
PI 2 BLU
2
Blue
PI 2 BLK
2
Black
PI 3 RED
3
Red
PI 3 BLU
3
Blue
PI 3 BLK
3
Black
Catalog Numbering System
The PI System is available in sections up to 8' in length for continuous row wiring by simply plugging the sections
together. Each PI section is factory wired to the ballast leads. Color coding of wires is as follows:
PI-1 = One Circuit - 2 Wires: one black, one white
PI-2 = Two Circuits - 3 Wires: one black, one blue, one white
PI-3 = Three Circuits - 4 wires: one black, one blue, one red, one white
When ordering the PI2/PI3 System it is necessary to specify the number of fixtures required for each circuit. Each circuit in
fixture must be ordered as a separate line item, with a different hot wire color specified. All wiring to external feeds, using
cord or cord & plug, are responsibility of installing licensed contractor. Cord and cord & plug sets must be ordered
separately if PI option is chosen.
No internal fixture
access required for
installation or
disconnecting power.
Code Compliance
• UL/cUL Certified for Make/Break
under load (UL2549)
• Meets NEC requirements for
ballast disconnect (NEC 410.73G)
• Allows for addition of Occupancy
Sensor without hard connections
• Receptacles complete with
insulating dustcap
Cooper Lighting’s F-Bay Modular Power Supply option allows external fixture access for safe and easy servicing. There is no need
to remove lamps or reflectors to disconnect fixture power with F-Bay Modular Power Supply. Access to the individual fixtures
power supply allows servicing without turning off all the fixtures disrupting occupants. F-Bay Modular Power Supply is a time
saver in installation – simply plug & power.
1
2
Modular F-Bay Power Supply
1.
Modular Power Supply Receptacle supplied
mounted into fixture Access Plate.
2.
Modular Power Cord & Plugs in 120, 277, 347,
& 480V configurations for easy plug & power
into existing supply.
Modular Motion Sensor Option
supplied with Mounting Box and