background image

Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

08/02/2008 3:00:44 PM

Specifications and Dimensions subject to change without notice.

ADF042290

PI OPTION ORDERING INFORMATION

BLK=Black Hot

PI1= Single

Circuit

NG= No Ground (ground

provided by fixture body)

WG= With Ground 

(separate ground wire 

in harness)

P I 1   -   S i n g l e   C i r c u i t   P l u g - I n

S A M P L E   N U M B E R :   P I 1 B L K - W G

BLK=Black Hot
BLU=Blue Hot

PI2= Two

Circuit

NG= No Ground (ground 

provided by fixture body)

WG= With Ground (separate

ground wire in harness)

P I 2   -   T w o   C i r c u i t   P l u g - I n

S A M P L E   N U M B E R :   P I 2 B L K - W G

Leave Blank=Single

Neutral
/WHT=White Neutral
/GRY=Gray Neutral

Leave Blank=Single

Neutral
2NEU=Two Neutrals

BLK=Black Hot
BLU=Blue Hot
RED=Red Hot

PI3= Three

Circuit

NG= No Ground (ground

provided by fixture body)

WG= With Ground (separate

ground wire in harness)

P I 3   -   T h r e e   C i r c u i t   P l u g - I n

S A M P L E   N U M B E R :   P I 3 B L K - W G

Leave Blank=Single

Neutral
/WHT=White Neutral
/GRY=Gray Neutral

Leave Blank=Single Neutral
2NEU=Two Neutrals

For complete product data, reference the Fluorescent
Specification binder. Specifications & dimensions subject
to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.

Catalog

Circuit

Number

Number of

Wired To

Suffix

Circuits

Ballast

PI 1 BLK

1

Black

PI 2 BLU

2

Blue

PI 2 BLK

2

Black

PI 3 RED

3

Red

PI 3 BLU

3

Blue

PI 3 BLK

3

Black

Catalog Numbering System

The PI System is available in sections up to 8' in length for continuous row wiring by simply plugging the sections
together. Each PI section is factory wired to the ballast leads. Color coding of wires is as follows:
PI-1 = One Circuit - 2 Wires: one black, one white
PI-2 = Two Circuits - 3 Wires: one black, one blue, one white
PI-3 = Three Circuits - 4 wires: one black, one blue, one red, one white

When ordering the PI2/PI3 System it is necessary to specify the number of fixtures required for each circuit. Each circuit in
fixture must be ordered as a separate line item, with a different hot wire color specified. All wiring to external feeds, using
cord or cord & plug, are responsibility of installing licensed contractor. Cord and cord & plug sets must be ordered
separately if PI option is chosen.

No internal fixture

access required for

installation or 

disconnecting power.

Code Compliance

• UL/cUL Certified for Make/Break 

under load (UL2549)

• Meets NEC requirements for 

ballast disconnect (NEC 410.73G)

• Allows for addition of Occupancy

Sensor without hard connections

• Receptacles complete with 

insulating dustcap

Cooper Lighting’s F-Bay Modular Power Supply option allows external fixture access for safe and easy servicing. There is no need
to remove lamps or reflectors to disconnect fixture power with F-Bay Modular Power Supply. Access to the individual fixtures
power supply allows servicing without turning off all the fixtures disrupting occupants. F-Bay Modular Power Supply is a time
saver in installation – simply plug & power.

1

2

Modular F-Bay Power Supply

1.

Modular Power Supply Receptacle supplied 

mounted into fixture Access Plate.

2.

Modular Power Cord & Plugs in 120, 277, 347,

& 480V configurations for easy plug & power

into existing supply.

Modular Motion Sensor Option 

supplied with Mounting Box and

Modular Power Supply Receptacle.

Reviews: