Assembling your fixture

Step 1:

  Loosen the swivel bolt (F) located on the back

              of the fixture.

Step 2:

  Thread the junction box coverplate (E) onto the 

              mounting arm (D) and secure with the locknut 
              provided (B) using pliers to tighten. 

Note:  

The locknut should be on the outside of the 

junction coverplate.

Wiring your fixture

Note: 

This fixture should be mounted to a grounded junction box.

Step 1:

  Turn off the power at the main fuse/breaker box.

Step 2:

  Connect the white house supply wire to the white fixture wire using 

              a wire nut.

Note:  

Wire nuts not supplied.  Connect the black house supply wire to the

black fixture wire using a wire nut.  Connect the house supply ground wire to
the fixture ground wire using a wire nut.

Step 3:

  Attach fixture and coverplate to the junction box and fasten securely

              with screws, making sure no wires are sticking out from underneath 
              the coverplate.

Step 4:

  Apply silicone caulk around the edges of the coverplate to provide a 

              watertight seal from rain and moisture.

Step 5:

  Turn on power at main fuse/breaker box.  

Note: 

This fixture can be used with a dimmer switch to adjust light output.  To 

install a dimmer switch:  Use a dimmer switch designed for incandescent light-
ing that has a rating of 150 watts or higher.  Follow the installation instructions
included with the dimmer switch.  Keeping the halogen bulb in a dim mode for
an extended period of time may shorten the life of the bulb.  To achieve maxi-
mum bulb life, occasionally turn the switch to full brightness for a few hours.

Aiming your fixture

For optimum performance halogen fixtures must be mounted so that the bulb 
is within 4 degrees of horizontal.  Adjust fixture vertically to desired position and
tighten swivel bolt securely.

Servicing your fixture

CAUTION:  

When replacing bulb in the fixture, always replace with

the same wattage bulb or a lower wattage bulb.  DO NOT replace with
a bulb of greater wattage than specified on the fixture.  To do so could
create a fire hazard and or shorten the life of the bulb.

Note:  

If lens is replaced, use only tempered safety glass of equal thickness.

E

B

D

F

MQF150_W 825-0143.qxd:MQF150 325-1524.qxd  5/15/08  9:20 AM  Page 3

Summary of Contents for CMQF150

Page 1: ...ENGLISH ESPA OL FRAN AIS MQF150 CMQF150 MQF150W CMQF150W Instruction Manual Instrucciones Directives MQF150_W 825 0143 qxd MQF150 325 1524 qxd 5 15 08 9 20 AM Page 1...

Page 2: ...rce any other connection voids warranty Fixture should be installed by a qualified electrician or by persons with experience in household wiring The electrical system and the method of electrically co...

Page 3: ...sure no wires are sticking out from underneath the coverplate Step 4 Apply silicone caulk around the edges of the coverplate to provide a watertight seal from rain and moisture Step 5 Turn on power at...

Page 4: ...r of the product A purchasers receipt or other proof of date of original purchase acceptable to the Company is required before warranty performance shall be rendered This warranty only covers product...

Page 5: ...All returned products must be accompanied by a Return Goods Authorization Number issued by the Company and must be returned freight prepaid Any product received with out a Return Goods Authorization...

Page 6: ...Lus para usar en lugares h medos Debe conectar el artefacto a una fuente de alimentaci n de 120 V 60 Hz cualquier otra conexi n anula la garant a El artefacto debe ser instalado por un electricista co...

Page 7: ...onexiones con toma a tierra Paso 1 Apague la electricidad desde la caja de fusibles interruptores autom ticos Paso 2 Conecte el cable de suministro blanco del edificio al cable blanco del aparato usan...

Page 8: ...so 1 Retire la cubierta del vidrio quitando los dos 2 tornillos que se encuentran en la parte posterior del alojamiento y que sujetan la cubierta Paso 2 Usando un pa o limpio o guantes retire el foco...

Page 9: ...as expresas m s que la descripta anteriormente LA COMPA IA NO SERA RESPONSABLE DE DA OS INCIDENTALES ESPECIALES O CONSIGUIENTES QUE RESULTEN DEL USO DEL PRO DUCTO O SE ORIGINEN EN CUALQUIER INFRACCION...

Page 10: ...das 800 334 6871 Impreso en China ESPA OL 10 Cooper Lighting LLC no se hace responsable por los da os que puedan experimentar las mercanc as en tr nsito Los productos reparados o reem plazados estar n...

Page 11: ...r uniquement Le luminaire est list cULus pour l utilisation dans des lieux humides L appareil doit tre reli une source secteur de 120 volts 60 Hz toute autre connexion annule la garantie Le luminaire...

Page 12: ...tif Remarque Le dispositif doit tre mont une bo te de connexion reli e la terre tape 1 Eteigner la principale bo te fusibles tape 2 Connecter le fil blanc d alimentation de maison au fil blanc du disp...

Page 13: ...curit d gale paisseur Comment remplacer l ampoule tape 1 Retirer la couverture de lentille en verre en enlevant d abord les deux 2 vis au dos du bo tier qui tient la couverture de lentille en verre e...

Page 14: ...m es autres que celle crite plus haut La soci t ne sera pas tenue pour responsable de tous dommages acces soires sp ciaux ou cons cutifs r sultant de l utilisation de ce produit ou de toute transgress...

Page 15: ...de cette garantie et sont inspect s leur exp dition Tout dommage visible ou masqu r sultant du transport doit tre signal au plus t t au transporteur qui a fait la livraison pour remplir une r clamati...

Page 16: ...LLC La reproduction de ce document est strictement interdite sans l autorisation pr alable par crit de Cooper Lighting LLC Pour le service la client le et ou pour des pi ces manquantes ou endommag es...

Reviews: