i
This manual should be considered as a permanent part of the air conditioning equipment. Please keep it properly.
We pursue a policy of continuous improvement in design and performance of products. The right is therefore reserved
to change specifications without notice.
Our company shall not be held responsible for any occasional damage to the air conditioner that arises during its
operation in specific environment.
This air conditioner must be used as a general air conditioner, and shall not be used for drying clothes, freezing foods,
cooling or heating and other purposes.
Please don't install the air conditioner in the following environments. Otherwise, fire, machine deformation or failure may
arise.
*
Places with spatter of oil (including machine oil).
Places with inflammable gases.
*
Places with sulfurated gases or silicon (e.g. hot spring, etc.).
*
*
Coastal areas with much salt or the places exposed to strong acids or bases
that may cause corrosion to machine.
●
Signal words (DANGER, WARNING, CAUTION, and NOTE) are used to indicate hazard seriousness.
Definitions of the hazard levels are provided below with respective signal words.
●
IMPORTANT NOTICE
●
●
●
●
●
●
Do not orient the air outlet immediately to animals and plants, since this may cause adverse effects thereon.
The installation and service engineering have to comply with local standards, laws and regulations.
As an "appliance inaccessible to the public", the installation height of indoor unit of the air conditioner shall be at
least 98-27/64 in.(2.5m).
This air conditioner can only be installed by dealers or professionals. The installation by user may lead to water
leakage, electric shock or fire.
In case of any question, please consult the dealer or the service center designated by our company.
●
●
●
●
For environmental protection, please don't dispose of the product casually. Our company can provide recycling service
based on relevant regulations, and provide replacement parts according to relevant standards.
Refer to the instruction manual for complete machine (outdoor unit) for product standard for indoor unit.
Refer to Installation & Maintenance Manual of outdoor unit for temperature operation range.
●
●
lease don t perform installation or s suc as refrigerant piping connection drain pipe connection and iring connection.
iolations ma result in s stem lea age electrical failure or fire.
●
o not pour ater into t e indoor or outdoor unit.
is mac ine is an electric product t at ma de elop serious electric
failure
en e posed to ater.
●
o not open t e ser ice co er of indoor or outdoor units it out turning
t e main po er suppl ot er ise t is ma
ring a out serious safet accident.
●
o not touc or ad ust safet de ices inside t e indoor or outdoor units. If t e are touc ed or read usted serious accident
ma arise.
●
Refrigerant leakage may bring about oxygen deficit-induced respiratory difficulty. In case refrigerant leakage is detected,
please turn off the main switch immediately, extinguish any naked flame, and contact service dealer.
●
Ma e sure air tig tness test is performed.
Refrigerant R
is non flamma le non to ic and odorless and ma produce to ic gases
en e posed to open flame.
ince t is refrigerant gas is ea ier t an air it ma result in lac of o gen t ere leading to reat ing difficulties
en
t e area near t e ground is filled it t is gas. erforming lea detection and gas tig tness test it o gen acet lene or
ot er flamma le and to ic gases ma cause e plosion so nitrogen is recommended for t is test.
●
e standards for safe refrigerant lea age in construction and s stem operation are determined ased on local regulations
or standards.
●
se
it medium or ig er sensing speed
it an operating time of . seconds or less or electric s oc or
fire ma arise.
●
or installation t e refrigerant piping must e firml connected efore t e operation of compressor. or repair t e
refrigerant piping must e mo ed andled and remo ed after t e stop of compressor.
●
lease don t s ort circuit t e protecti e de ice e.g. t e pressure s itc etc. during operation since t is ma cause fire
or e plosion.