background image

P

L

H

Minimum power cord section

mm

mm

mm

L

P
H

Fuse or air switch

955

899

396

378

700

596

MODE

16

25

1.5

10

1.0

2.5

CHML-U18RK2

CHML-U14RK2

Electricity supply

Electrical data

220-240V~,50Hz

220-240V~,50Hz

220-240V~,50Hz

mm

2

Size and clearance

CHML-U24RK3

CHML-U28RK4

P

L

H

Minimum power cord section

mm

mm

mm

L

P
H

Fuse or air switch

980

427
790

MODE

220-240V~,50Hz

mm

2

25

2.5

Electrical data

Electricity supply

Size and clearance

TECHNICAL DATA

GENERAL INFORMATION

TECHNICAL DATA

OUTDOOR UNIT WORKING TEMPERATURE RANGE

GENERAL INFORMATION

9

Indoor side DB/WB(

)

Outdoor side DB/WB(

)

Maximum cooling

32/23

43/26

Maximum heating

27/-

24/18

The operating temperature range (outdoor temperature) for cooling only unit is

   -15

~43

; for heat pump unit is -20

~ 43

.

CHML-U21RK3  

GENERAL INFORMATION

 

CHML-U36RK4

 

CHML-U42RK5

P

L

H

Minimum power cord section

mm

mm

mm

L

P
H

Fuse or air switch

1087

440

1103

MODE

220-240V~,50Hz

mm

2

25

2.5

Electrical data

Electricity supply

Size and clearance

Summary of Contents for CHML-U14RK2

Page 1: ...t Type Wall mounted Air Conditioner Thank you for choosing our product For proper operation please read and keep this manual carefully CHML U14RK2 CHML U18RK2 CHML U21RK3 CHML U24RK3 CHML U28RK4 CHML...

Page 2: ...l characteristics technical data and accessories of this appliance may be changed without notice Children should be supervised to ensure that they do not play with the appliance This appliance is not...

Page 3: ...d to indicate risk of property damage Indicates a hazard that would be assigned a signal word WARNING or CAUTION WARNING CAUTION DANGER NOTICE CONFORMITY AND RANGE GENERAL INFORMATION Please read this...

Page 4: ...repair be necessary contact your nearest authorized Service Centre The appliance shall be stored in a room without continuously operating ignition electric heater Do not pierce or burn s instructions...

Page 5: ...ectric shock Donot spray wateronindoorunit It may cause electric shock ormalfunction After removing the filter do not touch fins to avoid injury Do not use fire or hair dryer to dry the filter to avoi...

Page 6: ...Air switch should be included magnet buckle and heating buckle function it can protect the circuit short and overload Air Conditioner should be properly grounded Incorrect grounding may cause electric...

Page 7: ...and outdoor unit should be connected by a professional If the length of power connection wire is insufficient please contact the supplier for a new one Avoid extending the wire by yourself For the ai...

Page 8: ...turned on or off according to your requir ement automatically please do not turn on or turn off the unit freque ntly otherwise disadvantage effect may be caused to the unit Rated voltage of this air c...

Page 9: ...Valve Warning Be sure to cut off the power supply before cleaning the air conditioner otherwise electric shock might happen Wetting of air conditioner may cause the risk of electric shock Make sure no...

Page 10: ...ct has to be disposed at an authorized place for recycling of electrical and electronic appliances Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner O...

Page 11: ...ical data Electricity supply Size and clearance TECHNICAL DATA GENERAL INFORMATION TECHNICAL DATA OUTDOOR UNIT WORKING TEMPERATURE RANGE GENERAL INFORMATION 9 Indoor side DB WB Outdoor side DB WB Maxi...

Page 12: ...tion pipes and the connectiong wirings ofthe unit A unit B unit C and unit D must be corresponding to each other respective The appliance shall be installed in accordance with national wiring regulati...

Page 13: ...cable connecting cable To the power supply B brown black CHML U24RK3 An all pole disconnection switch having a contact separation of at least 3mm in all pole should be connected in fixed wiring Wrong...

Page 14: ...arance of the units that have been purchased Wrong wire connection may cause malfunction of some electric components After fixing cable ensure that leads between connection to fixed point have some sp...

Page 15: ...handle at the right side plate of the outdoor unit one screw Note The above figures are only intended to be a simple diagram of the appliance and may not correspond to the appearance of the units tha...

Page 16: ...65 45 50 70 75 12 19 Diameter mm 9 52 16 15 20 6 18K unit need to be installed the indoor unit Caution Installation Must be Performed in Accordance with the NEC CEC by Authorized Personnel Only conve...

Page 17: ...not use any other refrigerant than R32 MAINTENANCE INSTALLER INSTALLATION DIMENSION DIAGRAM INSTALLER 15 CHML U18RK2 CHML U21RK3 CHML U14RK2 30cm Space to the cover or above 30cm 50cm Air inlet side...

Page 18: ...its Have the length of refrigerating pipe and refrigerant charge amount been recorded Has the unit been safely grounded Problems Owing to Improper Installation The unit may drop vibrate or make noises...

Page 19: ...4 13 6 15 16 3 17 8 19 3 1 6 1 9 2 1 2 4 2 8 3 1 3 4 3 8 4 2 4 6 5 5 5 6 1 1 1 3 1 4 1 6 1 8 2 1 2 3 2 6 2 8 3 1 3 4 3 7 4 floor location wall mounted window mounted ceiling mounted Minimum room 2 ar...

Page 20: ...66129929357...

Reviews: