8 Malfunction Analysis

 Warning!

 

Repairing work should be done by Gree technicians. For saving your time and spending, 

please check the following malfunction analysis before contacting customer service center. 

Malfunction Phenomena

Malfunction Analysis

After turning off the air 

conditioner, the unit could not 

restart immediately.

The overload protection switch of the unit needs 3 mins before 

restarting. 

Odor gives out when the unit 

just turns on.

When air conditioning, odor or smoke that was sucked in is 

discharged again.

Slight noise is heard when the 

unit is running. 

The refrigerant flows in the liquid pipe will make some noise. 

There is mist coming from air 

outlet under cooling mode.

Indoor temperature declines too fast.

Creak sound is heard when the 

unit is running or shut down. 

When the ambient temperature changes, the panel and other 

parts expand or shrink, which might cause some grating sound. 

The air conditioner could not 

run. 

Whether the unit is powered off.

Whether the unit is disconnected with power supply.

Whether the circuit breaker trips off. 

Whether the voltage is too high or too low.

Whether  the TIMER  has  been  set  in  the  wireless  remote 

controller.

Notice: All  the  operations  above  should  be  done  by  Gree 

technicians. 

The cooling (heating) effect of 

the air conditioner is not good.

Wether the temperature is set properly.

Whether the inlet or outlet of the unit is blocked.

Whether the air filter is too dirty to cause blockage. 

Whether the windows and doors are closed.

Whether the airflow volume is set at low speed. 

Whether there is any heat source in the room. 

Wireless  remote  controller 

doesn't work.

If  the  wireless  remote  controller  doesn't  work  with  new 

batteraries, remove the back cover and press ”ACL” button to 

make it normal.

The air conditioner is under abnormal disturbance orchanging 

function too frequently, to make wireless remote controller cannot 

control. Cut off main power supply and re-electrify could resume 

normal operation.

Whether the controller is within the signal receiving area;

Whether there is blockage;

Check if the batteries in wireless remote controller are worn out, 

otherwise change the batteries.

8.1 Service Center

When the following phenomena appears, please stop operating immediately, cut off the power 

supply and contact service center for help. 

Harsh sound is heard when the unit is running.

When the fuse melts or the circuit breaker trips off frequently.

When some objects or water is sucked in the unit accidently. 

Summary of Contents for CH09UFC230VI

Page 1: ...MULTI DUCTLESS INVERTER HEAT PUMP OWNER S AND INSTALLATION MANUAL FLOOR AND CEILING TYPE INDOOR UNIT Models CH09UFC230VI CH12UFC230VI CH18UFC230VI CH24UFC230VI...

Page 2: ...mode conflicts with each of the COOL mode DRY mode and FAN mode while the COOL mode DRY mode and FAN mode are compatible between each other The appliance shall not be installed in the laundry The app...

Page 3: ...Important Notice 3 3 3 Installation Description 3 3 4 Electrical Wiring 6 3 5 Drainpipe Installation 7 3 6 Install the Connection Pipes 8 4 Part Names of Floor and Ceiling Type Indoor Unit 10 5 Workin...

Page 4: ...tened Do not damage wires or use the wires that are not recommended otherwise electric shock or fire may happen Please don t operate the unit with wet hands or electric shock may happen Do not put a f...

Page 5: ...lace where cool air can be distributed throughout the room Such a place where condensate water could be easily drained out Such a place that can handle the weight of indoor unit Such a place which is...

Page 6: ...be done by professional personnel when the air conditioner unit is moved to other place 3 3 Installation Description Ceiling type Floor type These two types of units have similar installing procedure...

Page 7: ...or unit Never remove the cap 5 Lift the unit and slide forward unit in place Refer to Fig 7 6 Screw tightly both hanger bracket setting bolts M8 Refer to Fig 5 7 Screw tightly both hanger bracket fixi...

Page 8: ...Hanger bracket setting bolt M8 Hanger bracket fixing bolt M6 Hanger bracket Fig 6 Fig 7 Fig 9 Fig 8 When installing the indoor unit you can refer the paper pattern for installation Make sure that the...

Page 9: ...2 3 and grounding terminal of the indoor unit Wiring shall be done properly as per the wiring diagram Note Be sure the wring terminals A B C D and piping joints A B C D of the indoor unit match with t...

Page 10: ...on The incorrect of wiring connection would lead malfunction of some of the electric parts Be sure to leave some space between the connecting end and the clamp end after the wiring is fixed The instal...

Page 11: ...ead is less than 1 6 4mm from the hose Refer to Fig 11 Fig 12 Wrap the attached sealing pad 11 over the clamp and drain hose to insulate Refer to Fig 12 No folding of drain hose inside the indoor unit...

Page 12: ...ermally untreated pipe and connectors with sponge and then tighten the sponge with plastic tape Notes During the piping do not pull any connector forcefully to prevent the capillary and other pipes fr...

Page 13: ...r Unit Connecting pipe Air outlet Air inlet Guide louver Air filter purifier in air inlet grille Front panel Suitable model CH09UFC230VI CH12UFC230VI CH18UFC230VI CH24UFC230VI Note Different models of...

Page 14: ...bulb temp Wet bulb temp Rated Cooling 80 0 26 7 67 0 19 4 95 0 35 0 75 0 23 9 Max cooling 80 0 26 7 67 0 19 4 115 0 46 1 75 0 23 9 Min cooling 67 0 19 4 57 0 13 9 67 0 19 4 57 0 13 9 Rated Heating 70...

Page 15: ...air conditioner and the remote control with dry cloth or a vacuum cleaner If damp cloth is used remove moisture by using dry cloth afterward Caution Do not use benzine solvent gasoline thinners or po...

Page 16: ...tion the room temperature Clean the air filter every week for higher efficiency by professional Close the window and door while operating the unit for saving energy Cover windows with a blind or a cur...

Page 17: ...e done by technicians Do not use pieces of wire instead of fuse Do not insert objects into the air inlet or outlet when the air conditioner is running as it may cause damage or personal injury Also pa...

Page 18: ...been set in the wireless remote controller Notice All the operations above should be done by Gree technicians The cooling heating effect of the air conditioner is not good Wether the temperature is se...

Page 19: ...en there is water leakage from indoor unit When the power cord is overheating Odor gives out when the unit is running 8 2 After sales Service Please contact the dealer if the air conditioner has any q...

Page 20: ...d twenty 120 days from date of manufacture Damage resulting from failure to use install or maintain the product in a manner consistent with our manufacturer s recommendations shall render the warranty...

Page 21: ...age conditions blown fuses open circuit breakers or damages due to the inadequacy or interruption of electrical service 6 Failure or damage due to floods winds fires lightning accidents corrosive envi...

Reviews: