2.5 Cooling and Heating Data Sheet in Rated Frequency
Rated cooling
condition(°C)
(DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution
(rps)
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
27/19
35/–
09K
0.9~1.2
41 to 43
Super High
High
34
Rated heating
condition(°C)
(DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution
(rps)
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
20/15
7/6
09K
2.0~2.6
3 to 5
Super High
High
41
Cooling:
Heating:
13 to 15
33 to 36
Cooling:
Rated cooling
condition(°C) (DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution
(rps)
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
27/19
35/-
12K
0.9 ~ 1.2
12 to 14
39 to 43
TURBO
High
54
Heating:
Rated heating
condition(°C) (DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution
(rps)
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
20/15
7/6
12K
2.1 ~ 2.6
34 to 37
3 to 5
TURBO
High
56
Rated cooling
condition(°C) (DB/
WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution
(rps)
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
27/19
35/24
18K
0.9~1.0
in:8~11
out:11~14
in:75~83
out:37~48
Super High
High
73
27/19
35/24
24K
0.9~1.0
in:8~11
out:11~14
in:75~83
out:37~48
Super High
High
75
Rated heating
condition(°C) (DB/
WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution
(rps)
Indoor
Outdoor
P (MPa)
T1 (°C)
T2 (°C)
20/15
7/6
18K
2.2~2.4
in:75~83
out:37~45
in:1~3
out:2~6
Super High
High
75
20/15
7/6
24K
2.2~2.4
in:75~83
out:37~45
in:1~3
out:2~6
Super High
High
80
Cooling:
Heating:
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.
Service Manual
Technical Information
11