background image

HEAT PUMP AIR TO AIR 

ICY Series (With WIFI)

M

ODELS

:

 

 

OWNER’S MANUAL

Designed by Cooper&Hunter International Corporation, Oregon, USA

www.cooperandhunter.com

F

or proper operation

,

 please read and 

k

eep this manual carefully.

CH-S09FTX

TB-W

CH-S12FTX

TB-W

CH-S18FTX

TB-W

CH-S24FTX

TB-W

EN

Эксклюзивный представитель климатического оборудования Cooper&Hunter

в Херсоне и Херсонской области магазин «Домотроника» www.ch.ks.ua

Summary of Contents for CH-S09FTXTB-W

Page 1: ...WNER S MANUAL Designed by Cooper Hunter International Corporation Oregon USA www cooperandhunter com For proper operation please read and keep this manual carefully CH S09FTXTB W CH S12FTXTB W CH S18F...

Page 2: ...s situation that if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard re...

Page 3: ...appliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and kno...

Page 4: ...amage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not...

Page 5: ...les before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Pr...

Page 6: ...nnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only 4 Precautions WARNING wire which can t be used for other purposes The grounding resistance...

Page 7: ...e installed in the line For the air conditioner without plug an circuit break far away from animals or plants If it is unavoidable please add the fence for safety purpose Select a location which is ou...

Page 8: ...oor Unit heating indicator temp indicator cooling indicator power indicator receiver window drying indicator display NOTICE Actual product may be different from above graphics please refer to actual p...

Page 9: ...button 13 X FAN button Note X FAN is the same with BLOW 10 TIMER ON TIMER OFF button 8 SLEEP button 5 button Send signal Turbo mode 8 heating function Set temperature Set time X FAN function TIMER ON...

Page 10: ...speed Press button to adjust fan blowing angle Cooling only unit won t receive heating mode signal If setting heat mode with remote controller press ON OFF button can t start up the unit Introduction...

Page 11: ...chs the preset temp as soon as possible button 5 Press or button once increase or decrease set temperature 1 F Holding or button 2s later set temperature on remote controller will change quickly On re...

Page 12: ...air conditioner is blowing fan at xed angle Horizontal louver will send air at the xed angle Hold button above 2s to set your required swing angle When reaching your required angle release the button...

Page 13: ...last setting sleep curve and blink The first entering will display according to the initial curve setting value of original factory 2 Adjust and button could change the corresponding setting temperatu...

Page 14: ...ote controller near the object of high temperature or low temperature in order to avoid detecting inaccurate ambient temperature TIMER ON button TIMER ON button can set the time for timer on After pre...

Page 15: ...at notch 2 speed or quiet mode according to the comparison between indoor ambinet temperature and set temperature Under heating mode indoor fan operates at notch 3 speed or quiet mode according to the...

Page 16: ...ecting with remote controller temperature indicator on indoor unit displays indoor ambient temperature When selecting with remote controller temperature indicator on indoor unit displays outdoor ambie...

Page 17: ...be adjusted Press TURBO button and the remote controller won t send signal Sleep function and 8 heating function can t operate at the same time If 8 heating function has been set under cooling mode pr...

Page 18: ...eries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Cover of battery box remove reinstall During operation point the remote contr...

Page 19: ...enance Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric shock Do not use v...

Page 20: ...ion Instructions 18 Before operation please finish the following configuration in order to realize Wifi control and the connection between air conditioner and intelligent device 1 Short distance contr...

Page 21: ...tting for air conditioner connecting router Step 2 Open App and the screen will show the air conditioner that you just connected Click this air conditioner to enter and realize short distance control...

Page 22: ...t the password Operation steps 1 Select the sever address Functions introduction NOTICE Please select the encrypt mode empty if your wifi has been set without password configuration If configuration s...

Page 23: ...sername is test Tap Forgot password and enter the page Forgot password Tap Get verification code to get a email verification code Enter a new password and tap OK to log in 2 Personal settings Purpose...

Page 24: ...device Tap Image to select the source of image Select from Default images or Take photo or Choose from photos and save an image be shown enable button Lock device to lock the device other smart phone...

Page 25: ...For timer type select On Then select the repeating days Save the setting of preset name 3 Set device image Please refer to step 1 in 2 1 3 Control functions 1 Common control functions General control...

Page 26: ...rt Phone Tablet PC 24 Tap babyroom and enter the page of air conditioner control Tap to turn on the control switch Tap or to increase or decrease temperature Tap to change working mode Tap to enter th...

Page 27: ...tions Set scene Preset Link Infrared control only applicable to smart phone with infrared emitter Set scene Preset the operation of several smart devices by one tap On the page Device tap the image of...

Page 28: ...as instructed above Tap to set the interval Tap Save Then the scene Back home will be in execution You may view the execution condition of the scene 3 Preset includes single device preset and multi de...

Page 29: ...bottom of the page babyroom Then you will enter the page Slide up and down to set the time If you want to synchronize the time tap synchronize Preset edit Tap Name to customize the preset name Preset...

Page 30: ...n is applicable to partial of models set in the master device slave devices will execute commands to realize devices Select a master device When the environment has satisfied the parameters as linkage...

Page 31: ...r limit or Lower limit Tap Mode and On Off to select the status of master device Then tap Save Step 2 Set time parameter for linkage Tap Time parameter to enter the page Set time Slide rightwards to t...

Page 32: ...p the days below Repeat to select the repeating days Then tap Save Step 3 Select Execute command Tap Execute command and enter the page Select device Tap the name of device that you want to control Ta...

Page 33: ...of several scenes 5 Infrared control only applicable to smart phone with infrared emitter Function Smart phone can be used as a remote controller Tap at the top right corner of the homepage Device Se...

Page 34: ...t and right arrows to set sleep time Tap up and down arrows to adjust temperature at a specific sleep time Menu functions Share Set History Feedback 1 Share To share quick configuration information an...

Page 35: ...odel name and wait for the download 2 Backup To keep backup of the quick configuration information and unit s information including backup to cloud and backup list on the cloud Backup to cloud Enter t...

Page 36: ...l unit 3 Settings User can set vibration message alerts server updates etc The server setting here must keep the same as the server setting in Configuration mentioned before Otherwise remote control w...

Page 37: ...pen panel Pull out the panel to a certain Use dust catcher or water to the water below 45 to clean it and then put it in a shady and cool place to dry panel cover tightly operation environment clean f...

Page 38: ...age pipe is damaged 1 Disconnect power supply 3 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Notice for recovery 1 Many packing materials are rec...

Page 39: ...einsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re ceiving window on indoor u...

Page 40: ...let Indoor temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution...

Page 41: ...the unit again Outdoor unit has vapor Heating mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water noise Air conditioner is turned on or tu...

Page 42: ...aking If the air conditioner operates under abnormal conditions it may cause Error code Heating indicator ON 10s OFF 0 5s F1 F2 C5 Troubleshooting Means defrosting status It s the normal phenomenon Pl...

Page 43: ...east 50cm At least 30cm Space to the obstruction Space to the obstruction Space to the obstruction Space to the obstruction Space to the wall At least 200cm At least 30cm At leas t 250c m At leas t 15...

Page 44: ...2 The place with high frequency devices such as welding machine medical equipment 3 The place near coast area 4 The place with oil or fumes in the air 5 The place with sulfureted gas 6 Other places w...

Page 45: ...able away from the copper tube 9 The appliance shall be installed in accordance with national wiring regulations grounding with specialized grounding device by a professional Please make sure it is al...

Page 46: ...nding installation dimensional drawing ac cording to actual wall mounted plate of 55 70 on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downw...

Page 47: ...ng out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left...

Page 48: ...screw on the wiring cover and then take Step seven connect wire of indoor unit 4 Wrap the indoor pipe and joint of con then wrap it with tape Step six install drain hose Installation of indoor unit to...

Page 49: ...n the line The air switch should be all pole parting and the contact parting distance should be more than 3mm 3 Remove the wire clip connect the power connection wire to the wiring terminal according...

Page 50: ...ng The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the indoor unit 1 Put the bound pipes in the wall pipe and then make them pass through...

Page 51: ...For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacity of 10...

Page 52: ...referring to the sheet below gas pipe liquid pipe liquid valve gas valve union nut pipe joint Hex nut diameter Tightening torque N m 6 9 52 12 16 19 30 40 45 55 60 65 70 75 15 20 1 Remove the wire cl...

Page 53: ...e outlet pipe hole of indoor unit Slant the drain hose slightly dow nwards The drain hose can t be The water outlet can t be placed in water in order to drain smoothly Installation of outdoor unit U s...

Page 54: ...ure decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw caps of valves and refrigerant ch...

Page 55: ...r damaging the parts Is there any obstruction in the air inlet Is the inlet and outlet of piping hole been covered and outlet heating capacity The dust and sundries caused during installation are remo...

Page 56: ...l refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolonged length of liquid pipe additional...

Page 57: ...4a Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 9 52 or 12 12 16 19 22 2 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350...

Page 58: ...ng pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the port with expander No...

Page 59: ...e of wired controller 1 1 LCD Display of Wired Controller Fig 1 1 2 LCD display If the product you bought is equipped with wired controller please refer to the following introductions of wired control...

Page 60: ...ration temperature setting On Off operation Mode setting are disabled by the remote monitoring system 13 Turbo Turbo function state 14 MEMORY Memory function The indoor unit resumes the original setti...

Page 61: ...unit to enter cancel the Memory function If memory is set indoor unit after power failure and then power recovery will resume the original setting state If not the indoor unit is defaulted to be off...

Page 62: ...g Under ON state of the unit press the Mode to switch the operation modes as the following sequence Auto Cooling Dry Fan Heating 3 3 Temperature Setting Press or to increase decrease the preset temper...

Page 63: ...ton is pressed LCD will display xx Hour with ON blinking In this case press or button to adjust timer on and then press Timer to Timer off setting Under on state of the unit without timer setting if T...

Page 64: ...3 5 2 Timer on Setting under the Off State of the Unit Timer range 0 5 24hr Every press of or will make the set time increased or decreased by 0 5hr If either of them is pressed continuously the set t...

Page 65: ...unction to enter the Swing setting interface with blinking After that press Enter Cancel to cancel this function Swing setting is shown as Fig 3 6 1 Fig 3 6 1 Swing Setting Notes Sleep Turbo or Blow s...

Page 66: ...function In the Cooling or Dry mode the temperature will increase by 1 C after the unit runs under Sleep1 for 1hr and 1 C after another 1hr After that the unit will run at this temperature In the Hea...

Page 67: ...he setting value In the Cooling or Heating mode press Function till the unit enters the Turbo setting status and When the Turbo function is activated press Function to enter the Turbo setting status a...

Page 68: ...be turned on automatically Press Function in the Heating mode to enter the E heater setting interface and then press Enter Cancel to cancel this function Press Function to enter the E heater setting...

Page 69: ...Function to the Blow setting status and then press Enter Cancel to cancel this function Blow function setting is as shown in Fig 3 10 1 Fig 3 10 1 Blow Setting Notes When the Blow function is activat...

Page 70: ...the wired controller after power failure will resume its original running state upon power recovery Memory contents On Off Mode set temperature set fan speed and Lock function 4 Installation and Disma...

Page 71: ...the installation holes and then let it go through the rectangular hole behind the soleplate of the wired controller with screws M4X25 4 Insert the four core twisted pair line into the slot of the wire...

Page 72: ...lines of the wired controller must be the shielding twisted pair lines 4 3 Dismantlement of the Wired Controller 1 3 4 2 5 Errors Display If there is an error occurring during the operation of the sy...

Page 73: ...r demagnetization protection HE Over phase current protection P5 PFC protection Hc Compressor desynchronizing H7 IPM Temperature Protection P8 IPM Current protection H5 Over power protection L9 Compre...

Page 74: ...66160000324 Designed by Cooper Hunter International Corporation Oregon USA www cooperandhunter com...

Reviews: