Prior to the first use, especially if outdoor temperature is below zero, let the
device heat up at room temperature for 1 hour. It is recommended to use
the device at temperature ranging from 5°C to 40°C, and relative humidity
not more than 80%. Use only clean water with temperature not more than
30°C. Prior to a switching the device off for a long time (more than 2 days),
drain water from the water tank. Read instructions how to clean the
humidifier in section «Recommendations on maintenance of the device».
5
When first pressed, the “OL” indication will appear - this means that the
humidity limit has not been set, and the device will work until the water
runs out. On the second press, the hygrostat sets the desired humidity
limit to 40%. Each subsequent press increases the limit by 10% until “OL”
appears on the display. If within 5 seconds you do not perform any
actions, the device will perceive the selected humidity level as desired, and
the Hygrometer will again show the current humidity in the room.
You can see which humidity was set earlier by pressing this button once -
the previously set desired humidity level flashes on the display. If you want
to change it, click the button again.
When the desired level of humidity is reached, the device will continue to
operate with minimum evaporation rate. If the desired humidity level is not
reached, the device continues to operate at the intensity specified by the
“Manual / Evaporation Rate” button.
When choosing the desired humidity, keep in mind that the humidity in the
immediate vicinity of the device is always higher.
Control panel
1. Maximum evaporation rate
2. The average evaporation rate
3. Minimum evaporation rate
4. Hygrometer
5. Low water indicator
6. On / off tank illumination (night light)
7. Off Timer (1 - 12 hours)
8. Manual setting of the humidity level
9. On / off device
10. On / off ionization mode
11. Night mode
12. Kid / Auto mode
13. Manual Mode / Evaporation Rate
• On / Off Button (9):
If the device is plugged in, the “On / Off” indication on the device
display automatically lights up. To turn on the device, press the
“On / Off” button. The hygrometer of the device will show the
current humidity in the room, and the device will start working with
the Average evaporation rate by default. Press this button to turn
off the instrument
• Setting the humidity level in manual mode (Hygrostat function) (8)
This button only works in Manual mode. Press this button to set the
desired level of humidity in the room. The hygrometer on the
instrument display will flash.
CONTROL OF THE DEVICE
•
Button for setting the timer operation time (7):
This button allows you to set the duration of the device operation in the
range from 1 to 12 hours. Press this button to select the duration of the
instrument. The hygrometer on the display will be replaced by flashing
timer numbers. Set the desired duration of work by successively pressing
the “Timer 1-12 hours” button. If within 5 seconds you do not perform any
actions, the device will set the timer to the selected duration, and the
Hygrometer will be displayed again. When you select the duration of the
work “00” timer is off. In Night mode, the timer is preset for 8 hours, so
when you press the Night mode button, the device will automatically turn
off after 8 hours if you have not specified a different duration of operation.
If the timer is set, but you have chosen a different mode of operation or
the water has expired, the timer is automatically reset.
•
Tank light (6):
Press this button to turn on the tank under-light. Pressing it again will turn
off the backlight. The function is available regardless of the amount of
water in the tank.
•
Manual Mode / Evaporation Rate (13):
It is a button for selecting one of four mutually exclusive modes of
operation. When you turn on the device Manual mode is the default
operation mode. Pressing this button takes the device to Manual
mode, canceling the settings of other modes and automatically setting
the device to the minimum evaporation rate.
Summary of Contents for CH-3040
Page 1: ......
Page 2: ......
Page 10: ...8 8 9 10 11 13 13 14 15 16 1 2 3 4 5 6 7 8 9 Cooper Hunter Cooper Hunter 1 40 60 220 240 50...
Page 11: ...9 2 30 C...
Page 13: ...11 1 2 3 4 5 6 7 1 12 8 30 5 40 80 9 10 11 12 13 9 8 3...
Page 14: ...12 OL 40 10 OL 5 7 1 12 1 12 5 00 8 8 6 13 12 2 55 40 40 60 60 2 11 SMART 5...
Page 15: ...https climagroup com ua brands ch 13 1 1 2 1 3 1 4 1 1 1 2 8 2 SMART 5 10 5 4 3 4 2 1 2 6 5...
Page 16: ...14 1 2 3 4 1 5 10 2 5 2 3 4 1 2 1 2 3 30 5 40 80 30 2 7...
Page 17: ...15 4 3 4 80 8 12...
Page 18: ...https climagroup com ua brands ch 16 9 12...
Page 19: ......
Page 20: ......