5
4
3. IPM continuity check
Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the
IPM. Use a digital tester to measure the resistance between P and UVWN; UVW and N.
Digital tester
Normal resistance value
Digital tester
Normal resistance value
(+)Red
(-)Black
∞
(Several M
Ω
)
(+)Red
(-)Black
∞
(Several M
Ω
)
P
N
U
N
U
V
V
W
W
(+)Red
4: Indoor AC Fan Motor
Measure the resistance value of each winding by using the tester.
Position
Resistance Value
RPG13B
RPG50B(YKFG-50-4-1)
Black - Red
100.5
Ω±
8%
(
68
°
F
/
20
°
C)
(Brand: Weiling)
100
Ω±
8%
(
68
°
F
/
20
°
C)
(Brand: Dayang)
82.2
Ω±
8%
(
68
°
F
/
20
°
C)
(Brand: Weiling)
85
Ω±
8%
(
68
°
F
/
20
°
C)
(Brand: Dayang)
White - Black
64.5
Ω±
8%
(20
°
C /68
°
F)
(Brand: Weiling)
68.5
Ω±
8%
(20
°
C /68
°
F)
(Brand: Dayang)
72.3
Ω±
8%
(20
°
C /68
°
F)
(Brand: Weiling)
57.8
Ω±
8%
(20
°
C /68
°
F)
(Brand: Dayang)
Summary of Contents for CH-09DKT230VI
Page 29: ...27 IPM board TO MAIN W connecttothecompressor V OVAC standby 10 200VAC running...
Page 41: ...39 P W N U...
Page 42: ...40 N V N W...