59
Installation and Maintenance
Service Manual
a
b
Remove the screw on the solenoid coil, and
then remove the solenoid coil.
Unsolder the pipes (including the soldering
joint among the 4-way valve, the compressor,
the condenser, the gas valve and the liquid
valve) connected to the compressor at first.
(NOTE: Before unsoldering the joints, discharge
the refrigerant completely
)
Remove the 3 foot nuts fixing the compressor
with wrench, and then remove the compressor.
screw
solenoid coil
4-way valve assy
nut
compressor
gas valve
liquid valve
Steps
10. Remove solenoid coil
11. Remove compressor
Procedure