Revised: 01/09/2016 13/02/17
4
Product Features
COONARA “GRANGE” INBUILT AND FREESTANDING GAS LOG HEATERS
NAME PLATE
MODEL-GRANGE
GAS TYPE
NATURAL
L.P.G
Manufacturer
MODEL TYPE
GAS INPUT
HIGH
LOW
HEAT OUTPUT
HIGH
LOW
Efficiency
Injector Size
Manifold Pressure
High
Low
A.G.A Approval
No to Code
AS4553-2008
Freestanding
Inbuilt
36 MJ/h
19 MJ/h
8.9 kW
4.3 kW
86.5 %
3.3 mm
0.7 kPa
0.35 KPa
AGA 7048 G
Freestanding
Inbuilt
36 MJ/h
19 MJ/h
8.9 kW
4.3 kW
86.5 %
1.9 mm
1.9 kPa
0.70 KPa
AGA 7048 G
Shamic
Sheetmetal
(Aust.)
Pty.Ltd
.
PO BOX 8,
KILSYTH,
VIC. 3136
To be installed by
an authorized
person in
accordance with
installation
instructions
provided with the
appliance.
Electrical
Conform to AS3100
240V 50 Hz 120 Watts Max
Air Pressure Switch
Aria 380 series 5471
Cut in Pressure
100 Pa
Cut out Pressure
90 Pa
Electrical Connection
Standard Flex. 2 Mt. 3 Pin Plug
Coonara “Grange” Freestanding and Inbuilt Gas Log Space Heaters
Zero Clearance to Combustible Materials
5.1 Star Energy Rate
Manual or remote operated controls. Optional thermostat
Electronic ignition.
External combustion air intake - prevents de-oxygenation of room air.
Delayed start room fan - prevents cold air being circulated at start-up.
Ability to duct heat to neighbouring rooms up to 12m from the heater – optional extra
only available for inbuilt heaters
Power flue.
Summary of Contents for grange
Page 15: ...Revised 01 09 2016 13 02 17 15 6mm Cement Sheeting required for floor installation ...
Page 19: ...Revised 01 09 2016 13 02 17 19 INTERNAL WALL UNDER FLOOR INSTALL WITH HORIZONTAL FLUE ...
Page 21: ...Revised 01 09 2016 13 02 17 21 DIMENSIONS OF APPLIANCE INBUILT MODEL ...
Page 25: ...Revised 01 09 2016 13 02 17 25 WIRING DIAGRAM PRESSURE SWITCH ...