background image

 
 
 

Limited One Year Warranty 

 

CoolWorks Inc. warrants this product, to original purchaser, for one year from purchase date to be free of defects in material and 
workmanship. 
 
Should any defect be discovered within one year of date of purchase, CoolWorks Inc. agrees to repair or replace the defective part or 
product at no charge other than handling and return freight charges, provided said part or product is returned with all shipping charges 
prepaid to CoolWorks Inc., Service Department, 819 A Street, San Rafael, CA  94901, accompanied by proof of purchase and a letter 
detailing the nature of the defect.  The Customer Service Department of CoolWorks Inc. should be contacted prior to any action in the 
event it is possible to correct the defect without returning the unit. 
 
This warranty does not apply to any unit that has been tampered with, or to damages incurred through negligence in use, faulty 
packing, or mishandling in transit by any common carrier.  Your remedy does not include loss of aquatic life, cost of inconvenience, 
or damage due to product failure.  In no event shall CoolWorks Inc. be liable for incidental or consequential damages. 
 
This warranty gives you specific legal rights; you may also have other rights, which vary from state to state. 

 
 

 
 
Service Information 

 

To assure years of dependable service, our products are made with high quality materials and are thoroughly tested prior to shipment. 
 
At CoolWorks, your satisfaction with our products is our top priority.  Should you encounter any form of product failure, please contact our 
Customer Service Department: 
 

CoolWorks Inc. 

819 A Street 

San Rafael, CA  94901 

Phone:  (415) 485-5552 

Fax:   (415) 258-9963 

Email:     [email protected] 

w w w . c o ol w o r k si n c. c o m 

 
This device should be serviced only by properly trained repair technicians.   Please do not attempt to service this product yourself. 
 

CoolWorks and Ice Probe are registered trademarks of CoolWorks Inc

Summary of Contents for IceProbe IPAC-50W

Page 1: ...1 IceProbe Thermoelectric Aquarium Chiller Model IPAC 50W Instructions Warranty For U S A Only ...

Page 2: ...rfaces 6 Do not use device for other than intended use 7 Provide four to six inches of air space around the fan and heat sink for air circulation 8 Do not plug the IceProbe directly into a 120VAC power source i e standard wall outlet This device is intended to operate at 12VDC and draws approximately 5 amps 9 Only power the IceProbe with the power supply included with the device 10 Do not attempt ...

Page 3: ...ead this entire manual carefully Assess the area where you intend to bulkhead the IceProbe before drilling any holes It is important to ensure there is adequate clearance for the probe and ample space for air circulation around the fins and fan In larger aquariums 20 to 55 gallons two or more Aquarium Chillers may be needed to achieve the desired temperature differential If you intend to install m...

Page 4: ... through the hole with the clear silicon washer on the outside dry side of the reservoir wall 4 Tighten the nylon nut on the threaded probe While a watertight seal can often be achieved by hand tightening the nut we recommend using an adjustable wrench However be careful not to over tighten the nut by applying excessive force The IceProbe can be oriented in any way Provided that the probe is fully...

Page 5: ...lightly cooler than the liquid around it To achieve the maximum temperature pull down the unit must run continuously for several days Optional Temperature Controller The chiller cools continuously when powered In most aquarium implementations the CoolWorks Proportional Temperature Controller is added to regulate the IceProbe s cooling power Temperature Controller IceProbe CoolWorks offers two Prop...

Page 6: ... when used in conjunction with CoolWorks temperature controllers Compressed air a small vacuum cleaner attachment or a small soft brush can be used to remove dust and lint from the fan and thereby extending its useful life If the fan motor is not running at all or very slowly contact CoolWorks Customer Service Probe Coating The solid aluminum probe which contacts the water is coated with a very du...

Page 7: ...l fuse has opened ON ON Thermoelectric cooling module failure Please contact a qualified electrician if the cause of the problem is related to your electrical outlet Replacement power supplies can be purchased from CoolWorks Resellers or CoolWorks Customer Service and can be easily installed Fan motor safety thermal fuse and thermoelectric cooling module repairs must be performed by the CoolWorks ...

Page 8: ... incurred through negligence in use faulty packing or mishandling in transit by any common carrier Your remedy does not include loss of aquatic life cost of inconvenience or damage due to product failure In no event shall CoolWorks Inc be liable for incidental or consequential damages This warranty gives you specific legal rights you may also have other rights which vary from state to state Servic...