Signal Wiring 

The RS-422/485 signal requires dedicated wire pairs for transmit and receive. The 

transmit wires are used to send data to as many as 10 receivers, as stated in the 

specifications of RS-422. Since the USBG-422MiNi uses RS-485 line driver technology, up 

to 32 receivers are possible. The following diagram shows RS-422 and RS-485 4-wire 

scheme: Settings are listed as follows: 
 

 

Figure 2 

 

RS-485 2-Wire Scheme 

The following diagram shows RS-485 2-Wire scheme: 

 

Figure 3 

Summary of Contents for USBG-422MiNi

Page 1: ...Mini USB to Terminal RS422 RS485 FTDI Plug in Adapter Product Manual Coolgear Inc Version 1 1 April 2018 Model Number USBG 422MiNi www coolgear com...

Page 2: ...to give the user of the product an understanding of its use with detailed diagrams and verbiage The manual allows the users to apply the product to their application Intended Audience This product is...

Page 3: ...er 2012 2008 Rs 5 2 2 Install in Windows XP Vista Server 2003 and 2008 5 2 3 Pin outs of the Terminal Block Connector 5 3 RS422 RS485 Pin outs 6 4 Signal Wiring 7 5 Notes Tips and Warnings 9 6 Support...

Page 4: ...terminal connector 1 1 Features TAA Compliant Supported by Windows 10 Adds a high speed RS 422 485 serial port 256 bytes receive buffer for high speed data throughput 128 bytes transmit buffer for hi...

Page 5: ...ug the USB COMi PL to the USB port The driver will be installed automatically via the Internet 2 2 Install in Windows XP Vista Server 2003 and 2008 Connect your computer to Internet and plug USB COMi...

Page 6: ...ositive polarity 3 Input RxD Receive Data positive polarity 4 Input RxD Receive Data negative polarity 5 Power VCC DC 5V 6 Ground GND Signal Ground RS 485 Half Duplex Mode Pin out The table below show...

Page 7: ...are used to send data to as many as 10 receivers as stated in the specifications of RS 422 Since the USBG 422MiNi uses RS 485 line driver technology up to 32 receivers are possible The following diagr...

Page 8: ...S 485 operation of USBG 422MiNi allows for 2 wire cabling Several RS 485 2 wire devices are connected in parallel to the wires which is call bus topology Each device can either send or receive data at...

Page 9: ...Inspect the product closely for visual defects before putting it to use Keep away from areas where moisture builds this product contains electrical components that can be damaged by moisture build up...

Page 10: ...uct mini usb to terminal rs422 rs485 ftdi plug in adapter 2017 Coolgear Inc All Rights Reserved All products and accompanying digital documentation including images are the property and or trademarks...