5.
Replacement installation:
Position housing so that it is
centered in existing opening.
MAKE SURE HOUSING IS
FLUSH WITH FINISHED
CEILING OR WALL. After
making electrical and duct-
work connections (see steps
4, 5 and 6), nail housing in place. Drive nails through the hous-
ing where indicated by arrows.
ç
6. Install 3" round duct onto damper/duct connector. If rigid duct-
work is used, its seam should be positioned at top of damper/
duct connector. Tape the joint and extend ducting to a wall cap
or roof cap. Make sure the damper operates freely. Ceiling or
wall can now be finished.
5
. New installation in an existing ceiling or wall:
From above ceiling or behind wall,
position housing against stud or
joist. Trace outline of housing on ceiling or wall material. Set hous-
ing aside and cut opening. Place housing in opening such that
its BOTTOM EDGE IS FLUSH WITH FINISHED CEILING OR
WALL. 1/2" ceiling or wall material: Bend tabs outward 90
0
(use
a screwdriver if desired) to rest on top of ceiling or wall material
and provide extra stability. Nail in place using four nails to ensure
a solid, quiet installation.
7. Replace the motor plate removed in Step 1. Insert two motor
plate tabs into slots in housing and then pivot motor plate up
until the third tab on plate snaps into matching slot in housing.
Make sure tabs hold motor plate securely in place. Plug in
motor.
8. Squeeze grille springs together and insert springs into slots in
motor plate. Push grille up against ceiling or wall.
SERVICE PARTS
KEY
PART
NO. NUMBER DESCRIPTION
1
97011723 Grille Assembly (Includes Key Nos 1 & 2)
2
99140187 Grille Spring
3
99080254 Motor
4
98006791 Motor Plate
5
99020292 Blower Wheel
6
99260428 Nut #6-32 (2 Required)
7
97008632 Damper/Duct Connector
8
99271252 Receptacle
9
98006773 Wiring Cover
10
97008319 Housing Assembly
3
10
7
8
9
4
6
Always order replacement parts by "PART NUMBER" - not "KEY NO."
2
5
1
99042877D
Limited Warranty
In the sale of its products, American Coolair Corporation agrees to correct, by repairs or replacement, any defects in workmanship or material that may
develop under proper and normal use during the period of one year from date of shipment from factory. Any product or part proving, upon American
Coolair’s examination, to be defective during limited warranty period will be repaired or replace, at American Coolair’s option, f.o.b. factory, without charge.
Deterioration or wear caused by chemicals, abrasive action or excessive heat shall not constitute defects.
Motors are guaranteed only to the extent of manufacturer’s warranty.
American Coolair’s limited warranty does no apply to any of its products or parts that have been subject to accidental damage, misuse by the user, unau-
thorized alterations, improper installation or electrical wiring, or lack of proper lubrication of other service requirements established by American Coolair.
Repairs or replacements provided under the above terms shall constitute fulfillment of all American Coolair’s obligations with respect to limited warranty.
THE LIMITED WARRANTY STATED HEREIN IS IN LIEU OF ALL OTHER WARRANTIES. EXPRESS, STATUTORY OR IMPLIED, INCLUDING WITHOUT
LIMITATION THAT OF MERCHANTABILITY AND FITNESS.
NO LIABILITY FOR REINSTALLATION COST OF FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY NATURE IS ASSUMED
OR SHALL BE IMPOSED UPON AMERICAN COOLAIR.
AMERICAN COOLAIR CORP. / ILG INDUSTRY, 3604 MAYFLOWER ST.
JACKSONVILLE, FLORIDA 32205, TEL: 904-389-3646
NOTE: If damper detaches from duct connector, re-insert it
by squeezing the duct connector top-to-bottom until the posts
inside spread apart far enough to fit the damper between
them. Guide the posts into the holders on the damper, while
slowly releasing the pressure on the duct connector.