Coolair CF670A1151 Instructions Download Page 2

5. 

Replacement installation:

  Position housing so that it is 

centered in existing opening. 

MAKE  SURE  HOUSING  IS 

FLUSH  WITH  FINISHED 

CEILING  OR  WALL.  After 

making  electrical  and  duct-

work connections (see steps 

4, 5 and 6), nail housing in place. Drive nails through the hous-

ing where indicated by arrows.

ç

6.  Install 3" round duct onto damper/duct connector. If rigid duct-

work is used, its seam should be positioned at top of damper/

duct connector. Tape the joint and extend ducting to a wall cap 

or roof cap. Make sure the damper operates freely. Ceiling or 

wall can now be finished.

5

.  New installation in an existing ceiling or wall:

From above ceiling or behind wall, 

position housing against stud or 

joist. Trace outline of housing on ceiling or wall material. Set hous-

ing aside and cut opening. Place housing in opening such that 

its BOTTOM EDGE IS FLUSH WITH FINISHED CEILING OR 

WALL. 1/2" ceiling or wall material: Bend tabs outward 90

0

 (use  

a screwdriver if desired) to rest on top of ceiling or wall material 

and provide extra stability. Nail in place using four nails to ensure 

a solid, quiet installation.

7.  Replace the motor plate removed in Step 1. Insert two motor 

plate tabs into slots in housing and then pivot motor plate up 

until the third tab on plate snaps into matching slot in housing. 

Make  sure  tabs  hold  motor  plate  securely  in  place.  Plug  in 

motor.

8.  Squeeze grille springs together and insert springs into slots in 

motor plate. Push grille up against ceiling or wall.

SERVICE PARTS

  KEY  

PART

  NO.   NUMBER  DESCRIPTION
 

97011723  Grille Assembly (Includes Key Nos 1 & 2)  

 

99140187  Grille Spring 

 

99080254  Motor 

 

98006791  Motor Plate

 

99020292  Blower Wheel 

 

99260428  Nut #6-32 (2 Required)

 

97008632  Damper/Duct Connector

 

99271252  Receptacle

 

98006773  Wiring Cover

  10 

97008319  Housing Assembly

3

10

7

8

9

4

6

Always order replacement parts by "PART NUMBER" - not "KEY NO."

2

5

1

99042877D

Limited Warranty

In the sale of its products, American Coolair Corporation agrees to correct, by repairs or replacement, any defects in workmanship or material that may 

develop under proper and normal use during the period of one year from date of shipment from factory. Any product or part proving, upon American 

Coolair’s examination, to be defective during limited warranty period will be repaired or replace, at American Coolair’s option, f.o.b. factory, without charge.
Deterioration or wear caused by chemicals, abrasive action or excessive heat shall not constitute defects.
Motors are guaranteed only to the extent of manufacturer’s warranty.
American Coolair’s limited warranty does no apply to any of its products or parts that have been subject to accidental damage, misuse by the user, unau-

thorized alterations, improper installation or electrical wiring, or lack of proper lubrication of other service requirements established by American Coolair.
Repairs or replacements provided under the above terms shall constitute fulfillment of all American Coolair’s obligations with respect to limited warranty.
THE LIMITED WARRANTY STATED HEREIN IS IN LIEU OF ALL OTHER WARRANTIES. EXPRESS, STATUTORY OR IMPLIED, INCLUDING WITHOUT 

LIMITATION THAT OF MERCHANTABILITY AND FITNESS.
NO LIABILITY FOR REINSTALLATION COST OF FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY NATURE IS ASSUMED 

OR SHALL BE IMPOSED UPON AMERICAN COOLAIR.

AMERICAN COOLAIR CORP. / ILG INDUSTRY, 3604 MAYFLOWER ST.

JACKSONVILLE, FLORIDA 32205, TEL: 904-389-3646

NOTE: If damper detaches from duct connector, re-insert it 

by squeezing the duct connector top-to-bottom until the posts 

inside spread apart far enough to fit the damper between 

them. Guide the posts into the holders on the damper, while 

slowly releasing the pressure on the duct connector.

ç

ç

Reviews: