Coolair CF670A1151 Instructions Download Page 1

MODEL CF670A1151

CEILING/WALL VENTILATING FAN

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC  SHOCK, OR INJURY TO 

PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If you 

have questions, contact the manufacturer at the address or telephone 

number listed in the warranty.

2.  Before  servicing  or  cleaning  unit,  switch  power  off  at  service  panel 

and lock the service disconnecting means to prevent power from be-

ing switched on accidentally. When the service disconnecting means 

cannot be locked, securely fasten a prominent warning device, such 

as a tag, to the service panel.

3.  Installation  work  and  electrical  wiring  must  be  done  by  a  qualified 

person(s)  in  accordance  with  all  applicable  codes  and  standards, 

including fire-rated construction codes and standards.

4.  Sufficient  air  is  needed  for  proper  combustion  and  exhausting  of 

gases through the flue (chimney) of fuel burning equipment to prevent 

backdrafting. Follow the heating equipment manufacturer's guideline 

and  safety  standards  such  as  those  published  by  the  National  Fire 

Protection Association (NFPA), and the American Society for Heating, 

Refrigeration and Air Conditioning Engineers (ASHRAE), and the local 

code authorities.

WARNING

5. When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.
7. This unit may be used over a tub or shower enclosure when installed 

in a GFCI protected branch circuit.

8. If this unit is to be installed over a tub or shower, it must be marked as 

appropriate for the application.

9. Never place a switch where it can be reached from a tub or shower.

READ  AND  SAVE  THESE  INSTRUCTIONS

CAUTION

1. For general ventilating use only. Do not use to exhaust hazardous or 

explosive materials and vapors.

2. To avoid motor bearing damage and noisy and/or unbalanced impellers, 

keep drywall spray, construction dust, etc. off power unit.

3. Please  read specification label on product for further information and 

requirements.

SCREWDRIVER

SLOT

WIRING

COVER

HOUSING

FLAP

1.  Remove motor plate from housing by pushing down on rib in 

plate while pulling out on side of housing. Motor plate may also 

be removed by inserting a straight-blade screw driver into slot 

in housing and twisting screw driver.

2.  Remove  wiring  cover  from  housing  by  pulling  straight  out. 

Unit is shipped ready to wire through the top of housing. To 

wire through the side, bend housing flap to cover top hole and 

expose side hole. DO NOT BREAK OFF FLAP. If flap breaks, 

plug unused hole using standard electrical hole plug.

3. 

Turn off electrical power at service entrance 

and connect 

power cable  to housing using appropriate connector. Wire black 

to black, white to white, and green to green or bare wire. 

Push all wiring up into corner of unit and replace wiring cover. 

Make sure cover holds housing flap in place against side or top 

of housing. 

CAUTION: DO  NOT ALLOW WIRES TO EXTEND 

OUTSIDE OF WIRING BOX. Wire left exposed will become 

pinched or cut  when motor plate is installed. Electrical 

shock may result.

TABS

TABS

4.  Choose the location for your fan. For best performance, us the 

shortest possible duct run and a minimum number of elbows, 

For wall installations: Position unit so damper flap closes when 

unit is off.

MAKE  SURE  HOUSING 

WILL BE FLUSH WITH FIN-

ISHED CEILING OR WALL. 

Slotted tabs are provided to 

locate  housing  flush  with 

1/2" ceiling or wall material. 

Bend tabs outward 90

(Use 

a screw driver if desired) and 

position housing so that tabs 

rest against bottom edge of 

joists (or front of stud). Nail 

housing to joist or stud using 

four nails to ensure a solid, quiet installation. 

Ceiling installations:

 

Tabs on opposite side of housing can be bent outward to rest on 

top of 1/2" ceiling material and provide extra stability.

5

.  New installation prior to finishing the ceiling or wall:

INSTALLATION

120 VAC LINE IN

BLACK

BLACK

GROUND

WHITE TO

WHITE

SWITCH OR TIMER

GREEN TO

GREEN OR

BARE WIRE

SWITCH BOX

RECEPTACLE

WHITE TO

WHITE

BLACK TO

BLACK