Cool-Living CL-PAC121 Operating Instructions Manual Download Page 5

CL-PAC-121_122

5

12

PRODUCT DIAGRAM 

Control Panel 

 5 

Carry Handle 

Air Outlet & 

Louvers

Power Cord 

Upper Air Intake 

Lower Air Intake 

Air Exhaust Vent 

Filter

Location

LIGHT 

 12 

REMOTE CONTROL OPERATING INSTRUCTIONS

In Cooling or Dehumidifier (DRY) modes:  When sleep 
mode is selected the set temperature will automatically 
increase 2

°

F after 1 hour. After 2 hours, the set tempera-

ture will increase another 2

°

F for a total increase of 4

°

F.

Press the LIGHT button to turn the on the display Light.  
A small Light bulb icon will light up on the remote con-
trol display.

Press the SLEEP mode button to engage SLEEP 
mode.. This feature limits compressor usage and 
enhances energy savings by adjusting the set 
temperature while you are sleeping. Press the SLEEP 
button once more to disable Sleep Mode. Sleep Mode 
is not available in Auto or Fan Modes. 

Press the X-FAN button to enable the X-Fan function. 
When enable, X-Fan will force the fan to remain on once 
the unit is powered down. The fan stays on to dry out any 
remaining moisture in the unit to help minimize mold or 
bacteria growth. X-Fan cannot be set under Auto, Fan, or 
Heat (CL-PAC-122 only) modes.

In Heating mode (CL-PAC-122 only):  When sleep 
mode is selected the set temperature will automatically 
decrease 2

°

F after 1 hour. After 2 hours, the set tem-

perature will decrease another 2

°

F for a total increase of 

4

°

F.

REMOTE CONTROL 

SLEEP

SLEEP BUTTON 

LIGHT BUTTON 

X-FAN 

X-FAN BUTTON 

LOCK

LOCK FUNCTION 

x

Press “+” and “-” buttons together at the same time to 
lock the remote keyboard. Do this again to unlock.

AUTO 

AUTO MODE 

x

Press the MODE button to select Auto Mode. Once 
Auto Mode is selected the unit will automatically 
choose the operating mode based on the current room 
temperature. The temperature will not be displayed on 
the LED in this mode.

TEMP

MEASURE 

CHANGE BETWEEN F° and C° 

x

When the unit is off, press the MODE and “-” button 

to change between F° and C°.

REMOTE CONTROL OPERATING INSTRUCTIONS

Press the X-FAN button to enable the X-Fan function. 

When  enable,  X-Fan  will  force  the  fan  to  remain  on 

once the unit is powered down. The fan stays on to dry 

out any remaining moisture in the unit to help minimize 

mold  or  bacteria  growth.  X-Fan  cannot  be  set  under 

Auto, Fan, or Heat (CL-PAC-122 only) modes.

When the unit is off, press the MODE and “-” button 
to change between F° and C°.

Press  the  SLEEP  mode  button  to  engage  SLEEP 

mode.. This feature limits compressor usage and en-

hances energy savings by adjusting the set temperature 

while you are sleeping. Press the SLEEP button once 

more to disable Sleep Mode. Sleep Mode is not avail-

able in Auto or Fan Modes.  

In  Cooling  or  Dehumidifier  (DRY)  modes:    When 

sleep mode is selected the set temperature will auto-

matically increase 2°F after 1 hour. After 2 hours, the 

set temperature will increase another 2°F for a total 

increase of 4°F. 

In  Heating  mode  (CL-PAC-122  only):    When  sleep 

mode  is  selected  the  set  temperature  will  automati-

cally decrease 2°F after 1 hour. After 2 hours, the set 

temperature will decrease another 2°F for a total in-

crease of 4°F. 

Summary of Contents for CL-PAC121

Page 1: ...nted in Mexico SC 06 06 14 BPN NA Pags 8 SHN model CL PAC121_CL PAC122 804105214 Please read instructions carefully before operating the unit Models CL PAC 121 CL PAC 122 12 000 BTU Portable Air Conditioner OPERATING INSTRUCTIONS ...

Page 2: ...o not start or stop the unit by insertingor pulling out the power plug 6 Do not use an adapter plug or extension cord 7 Do not use the unit in the immediate surroundings of a bath a shower or a swimming pool 8 Do not insert anything into the air outlet Do not obstruct air inlet or outlet grills unless instructed by this manual 9 Do not let children play near this unit 10 Always inspect the cord fo...

Page 3: ...ot start POSSIBLE CAUSES The air conditioner is unplugged or not connected well The fuse is blown circuit breaker is tripped Power Failure The current interrupter device is tripped SOLUTIONS x Make sure the air conditioner plug is pushed completely into the out let x Check the house fuse circuit breaker box and replace the fuse or reset the breaker x The unit will automatically re start when power...

Page 4: ... 2 The TEST and RESET buttons should not be used as ĀONā and ĀOFFā switches 3 The cord and plug are not intended to offer protection to externally connected loads or supply circuits 4 The cord and plug are intended for indoor use only RESET TEST 4 MAINTENANCE Note Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit Clea...

Page 5: ...ss and buttons together at the same time to lock the remote keyboard Do this again to unlock AUTO AUTO MODE x Press the MODE button to select Auto Mode Once Auto Mode is selected the unit will automatically choose the operating mode based on the current room temperature The temperature will not be displayed on the LED in this mode TEMP MEASURE CHANGE BETWEEN F and C x Whentheunitis off press the M...

Page 6: ...more to savethe setting Press the ON OFFbuttonto clear a time setting Press the Save button to automatically rotate through the different speeds To disable Save mode and pick your own fan speed press the Save button again Press theHorizontal SwingButton toturnonand off the Horizontalswingmode Inhorizontalswingmode the louvers will rotate left andright tocirculatemore air Press the Left and Right S...

Page 7: ...pressingthe Upand DownSwingButton and button at the sametime TheSwing Icononthe Remote LCDwill blink twice whenthis isdisabled REMOTE CONTROL MODE MODE BUTTON ON OFF ON OFF BUTTON FAN FAN BUTTON BUTTONS TEMP BUTTON AUTO COOL DRY FAN HEAT Low Speed Medium Speed High Speed SIGNAL TRANSMITTER REMOTE CONTROL OPERATING INSTRUCTIONS 7 When the unit is in Air Conditioner or Heater CL PAC 122 mode you can...

Page 8: ...d window kit must be installed when the unit is in Air Conditioner Dehumidifier DRY or Heater CL PAC 122 only mode When using the unit as a fan it is not necessary to keep the exhaust hose and window kit connected to the unit 3 Temperature Select the desired temperature by pressing either źorŸ key when using the unit in Cooling or Heating CL PAC 122 only mode The digital thermostat will display th...