Manual lighting
NOTE:
If the ignitor does not work, unscrew the top of the ignitor and replace the battery.
•
If the ignitor does not work after replacing the battery, the barbecue can be lit manually.
•
Light a long match and pass it through the grill towards the rear burner, then depress
the rear burner control knob and turn it to the
HIGH
position.
•
Continue depressing the control knob for 10 seconds to allow the thermocouple to
warm.
•
Repeat the manual lighting procedure for the opposite burner.
Turning the burner off
•
When cooking is complete, turn the control knobs clockwise to the
OFF
position.
Leak test procedure
•
Ensure all gas valves are in the
OFF
position.
•
In a small container, mix a solution of water and detergent or soap.
•
Once the hose has been connected, turn on the valve at the gas bottle or mains as
appropriate.
•
Using a brush, apply the solution to the gas connection points and look for bubbles
forming - bubbling will indicate a leak
•
Turn off the valve and re-tighten the joint. Repeat the leak test
•
If the leak persists, turn off the gas at the isolation valves and contact a licensed gas fitter.