background image

Precision Air 

V6

 Inflator

Instruction Sheet

Size Setting Chart

1   Precision Air Inflator
1   Power Cord
1   Foot Pedal
1   Carrying Case

2   Latex Outlets
2   Extension Tips
1   Double Bubble Outlet

Precision Air Inflator Includes:

READ PRIOR TO USE:

1.

 This appliance is not to be used by persons (including children) with reduced physical, sensory or mental 

capabilities or lack of experience, unless supervised or instructed.

2. 

The Precision Air is a delicate electrical instrument and may malfunction or be damaged if connected to an 

outlet with other devices.  Always use a surge suppressor outlet and a dedicated electrical outlet at all times 
to avoid potential issues.  Do not use the Precision Air with an outlet that is being used by multiple electrical 
appliances or the unit may reset or shut down completely.

3. 

To prevent the risk of electrical shock, do not use the Precision Air Inflator outdoors when weather conditions 

are wet. Never operate unit on a wet floor or work area. 

4.

 Prior to plugging the Precision Air Inflator into an electrical outlet, verify that the electrical rating (listed on the 

label on the back of the Precision Air Inflator) is suitable for the outlet. The Precision Air is not recommended for 
use in countries where electrical current is not consistently regulated.      

5. 

Allow the unit to fully exhaust the air through the vent located on the bottom of the Precision Air before 

tapping the foot pedal to begin the next cycle.

6.

 Operate the Precision Air in a temperature controlled environment.  When working outdoors, keep the unit 

out of direct sunlight. Avoid operating unit outdo   ors in extremely hot weather. If the unit reaches temperatures 
that exceed normal working conditions,  the thermal shut-off control will automatically shut the system down.

7. 

If the Precision Air Inflator malfunctions or is damaged in any way discontinue use and unplug unit from 

electrical outlet. Contact an authorized Conwin Service Center for details on how to receive service.     

Never attempt to repair the Precision Air Inflator yourself. Opening the Precision Air Inflator case will automatically void manufacturer warranty. Contact an authorized Conwin Service Center for

all repairs.

Extension Tip

Foot Pedal

Digital Settings

Latex Outlet

To attach the outlets, firmly press 
on to each filling port.

Plug the foot pedal into 
the side of the unit.

Plug the power cord into the side 
of the unit and into an electrical 
outlet. (A power strip with a surge 
protector is recommended.) The 
digital display will appear when 
unit has power.

Reference the Size Setting Chart (Fig 1.0) to set 
the Precision Air for the proper balloon size. Set 
the appropriate number of Seconds by pressing 
the arrow buttons on the left side of the control 
panel digital display window.

Set the appropriate number of Tenths of a 
Second by pressing the arrow buttons on 
the right side of the control panel digital 
display window. 

The following settings should be used as guidelines for 
the Precision Air. Please note that size settings will vary 
  based on user preference, balloon color, manufacturer 
and from unit to unit. To adjust the size of balloon to 
your individual preference it is necessary to inflate test 
balloons. 

BALLOON SIZE

APPROX. TIME SETTING

5

"

 BALLOON

0.8 SECONDS

9

"

 BALLOON

1.5 SECONDS

11

"

 BALLOON

2.5 SECONDS

16

"

 BALLOON

8 SECONDS

1

1

2

2

3

CHILD WARNING

 

1.

 This appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience, unless supervised or instructed.

2.

 To prevent the risk of electrical shock, do not use the Precision Air Inflator outdoors when weather conditions are wet. Never operate unit on a wet floor or work area.

3.

 Prior to plugging the Precision Air Inflator into an electrical outlet, verify that the electrical rating (listed on the label on the back of the Precision Air Inflator) is suitable for 

the outlet. The Precision Air is not recommended for use in countries where electrical current is not consistently regulated.

Setting the Precision Air Inflator

Inflating Balloons with the Precision Air Inflator

Place the Extension Tip over the Latex Outlet 
when inflating 5

"

 balloons. Slide the neck of the 

balloon all the way down on the Extension Tip 
until the neck is touching the base. 

To achieve 

consistent results, do not cover the opening 

of the Extension Tips with your fingers.

For 9" balloons and larger, remove the 
Extension Tip and roll the neck of the balloon 
over the Latex Outlet. 

To achieve consistent 

results, do not cover the opening of the outlet 

with your fingers.

Tap the foot pedal to begin the inflation cycle. When the 
system automatically shuts-off, remove the balloons from 
the outlets without allowing any of the air to escape, and tie. 
Wait 3 seconds for the auto exhaust vent to shut off before the 
next cycle. For continuous run cycle tap foot pedal 3 times. To 
deactivate tap foot pedal once.

1

2

3

Using & Resetting

the Counter

• Every time the foot pedal is pressed the 
cycle count will be displayed on the digital 
display windows.
• The time setting for the inflation cycle 
will disappear once the foot pedal has 
been pressed. To verify or change the 
time setting for the inflation cycle, press 
any of the arrow buttons on the control 
panel once.
• The balloon time setting will be 
displayed on the digital window. Press the 
Reset button in the center of the control 
panel to set the counter back to zero.

Reviews: