Precision Air
V6
Inflator
Instruction Sheet
Size Setting Chart
1 Precision Air Inflator
1 Power Cord
1 Foot Pedal
1 Carrying Case
2 Latex Outlets
2 Extension Tips
1 Double Bubble Outlet
Precision Air Inflator Includes:
READ PRIOR TO USE:
1.
This appliance is not to be used by persons (including children) with reduced physical, sensory or mental
capabilities or lack of experience, unless supervised or instructed.
2.
The Precision Air is a delicate electrical instrument and may malfunction or be damaged if connected to an
outlet with other devices. Always use a surge suppressor outlet and a dedicated electrical outlet at all times
to avoid potential issues. Do not use the Precision Air with an outlet that is being used by multiple electrical
appliances or the unit may reset or shut down completely.
3.
To prevent the risk of electrical shock, do not use the Precision Air Inflator outdoors when weather conditions
are wet. Never operate unit on a wet floor or work area.
4.
Prior to plugging the Precision Air Inflator into an electrical outlet, verify that the electrical rating (listed on the
label on the back of the Precision Air Inflator) is suitable for the outlet. The Precision Air is not recommended for
use in countries where electrical current is not consistently regulated.
5.
Allow the unit to fully exhaust the air through the vent located on the bottom of the Precision Air before
tapping the foot pedal to begin the next cycle.
6.
Operate the Precision Air in a temperature controlled environment. When working outdoors, keep the unit
out of direct sunlight. Avoid operating unit outdo ors in extremely hot weather. If the unit reaches temperatures
that exceed normal working conditions, the thermal shut-off control will automatically shut the system down.
7.
If the Precision Air Inflator malfunctions or is damaged in any way discontinue use and unplug unit from
electrical outlet. Contact an authorized Conwin Service Center for details on how to receive service.
Never attempt to repair the Precision Air Inflator yourself. Opening the Precision Air Inflator case will automatically void manufacturer warranty. Contact an authorized Conwin Service Center for
all repairs.
Extension Tip
Foot Pedal
Digital Settings
Latex Outlet
To attach the outlets, firmly press
on to each filling port.
Plug the foot pedal into
the side of the unit.
Plug the power cord into the side
of the unit and into an electrical
outlet. (A power strip with a surge
protector is recommended.) The
digital display will appear when
unit has power.
Reference the Size Setting Chart (Fig 1.0) to set
the Precision Air for the proper balloon size. Set
the appropriate number of Seconds by pressing
the arrow buttons on the left side of the control
panel digital display window.
Set the appropriate number of Tenths of a
Second by pressing the arrow buttons on
the right side of the control panel digital
display window.
The following settings should be used as guidelines for
the Precision Air. Please note that size settings will vary
based on user preference, balloon color, manufacturer
and from unit to unit. To adjust the size of balloon to
your individual preference it is necessary to inflate test
balloons.
BALLOON SIZE
APPROX. TIME SETTING
5
"
BALLOON
0.8 SECONDS
9
"
BALLOON
1.5 SECONDS
11
"
BALLOON
2.5 SECONDS
16
"
BALLOON
8 SECONDS
1
1
2
2
3
CHILD WARNING
1.
This appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience, unless supervised or instructed.
2.
To prevent the risk of electrical shock, do not use the Precision Air Inflator outdoors when weather conditions are wet. Never operate unit on a wet floor or work area.
3.
Prior to plugging the Precision Air Inflator into an electrical outlet, verify that the electrical rating (listed on the label on the back of the Precision Air Inflator) is suitable for
the outlet. The Precision Air is not recommended for use in countries where electrical current is not consistently regulated.
Setting the Precision Air Inflator
Inflating Balloons with the Precision Air Inflator
Place the Extension Tip over the Latex Outlet
when inflating 5
"
balloons. Slide the neck of the
balloon all the way down on the Extension Tip
until the neck is touching the base.
To achieve
consistent results, do not cover the opening
of the Extension Tips with your fingers.
For 9" balloons and larger, remove the
Extension Tip and roll the neck of the balloon
over the Latex Outlet.
To achieve consistent
results, do not cover the opening of the outlet
with your fingers.
Tap the foot pedal to begin the inflation cycle. When the
system automatically shuts-off, remove the balloons from
the outlets without allowing any of the air to escape, and tie.
Wait 3 seconds for the auto exhaust vent to shut off before the
next cycle. For continuous run cycle tap foot pedal 3 times. To
deactivate tap foot pedal once.
1
2
3
Using & Resetting
the Counter
• Every time the foot pedal is pressed the
cycle count will be displayed on the digital
display windows.
• The time setting for the inflation cycle
will disappear once the foot pedal has
been pressed. To verify or change the
time setting for the inflation cycle, press
any of the arrow buttons on the control
panel once.
• The balloon time setting will be
displayed on the digital window. Press the
Reset button in the center of the control
panel to set the counter back to zero.