ƒ

 

Warning 

 

 

The camera requires periodic inspection. 

Contact an authorised technician to carry out the inspection. 
 

Stop using your camera when you find it malfunctioning. 

If the camera emits smoke or is unusually hot for a long period, a fire may be caused. 

 

Do not install the camera on a surface that can not support it. 

If the camera is installed on an inappropriate surface, it may fall and cause injury. 
 

Do not hold plug with wet hands. 

It could cause an electric shock. 

 

Do not dis-assemble the camera. 

It may result in an electric shock or other hazards. 
 

Do not use the camera close to a gas or oil leak. 

It may result in a fire or other hazards. 

Summary of Contents for CC-5351 DIR

Page 1: ...Manual CC 5351 DIR 1 Manual CC 5351 DIR Date January 2011 Convision Systems GmbH...

Page 2: ...vide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not insta...

Page 3: ...hot for a long period a fire may be caused Do not install the camera on a surface that can not support it If the camera is installed on an inappropriate surface it may fall and cause injury Do not hol...

Page 4: ...mension 8 Installation 9 Cable Connection 10 Camera Operation 10 Menu 10 Settings 10 Lens selection 12 Shutter conditions and speed control 13 White Balance control 14 BACKLIGHT 15 AGC Auto Gain Contr...

Page 5: ...mended by manufacturer 6 Power source This product should be operated only from the type of power source indicated on the marking label Precautions Operating Before using make sure power supply and ot...

Page 6: ...vacy Function The Privacy function conceals the areas you do not wish to appear on the screen Electronic IRIS The electronic IRIS function enables continuous automatic control of the shutter between 1...

Page 7: ...Manual CC 5351 DIR 7 Names and Functions of Parts Lens Vari Focal Auto Iris Lens OSD PCB...

Page 8: ...buttons Used for selecting items by moving the cursor up or down on the menu screen LEFT RIGHT buttons Used when changing item values by moving the cursor to the left or right on the menu screen VBS E...

Page 9: ...00mA AC24V 500mA regulated power supply To avoid fire or shock hazard must use a UL listed power supply Set the monitor impedance switch to 75 Check the impedance switch when the screen turns blurred...

Page 10: ...ntrol ATW AWC Manual Backlight OFF LOW MIDDLE HIGH AGC Auto Gain control OFF LOW MIDDLE HIGH DNR Digital Noise Reduction OFF LOW MIDDLE HIGH Sens Up Low Illumination OFF Auto Special Camera ID Colour...

Page 11: ...on is pressed available values and modes are displayed in order Please keep pressing the button until you get to the mode you wish to operate 4 Please select EXIT and then press the SETUP button to fi...

Page 12: ...he lens you wish to use by pressing the LEFT or RIGHT button MANUAL Manual lens selection DC VIDEO Auto Iris lens selection Note The brightness of the screen can be adjusted in DC mode The brightness...

Page 13: ...en ESC mode is on the speed is controlled automatically according to the brightness of the screen MANUAL The shutter speed can be controlled manually 3 Please select MANUAL mode if you wish to adjust...

Page 14: ...illumination If the environment including the light source is changed you have to adjust the white balance again MANUAL The manual adjustment mode enables finer adjustment Please select ATW or AWC fi...

Page 15: ...acklight function 1 Please position the arrow to point to BACKLIGHT in the SETUP menu by using the UP and DOWN buttons 2 Please select the mode you wish to operate by pressing the LEFT or RIGHT button...

Page 16: ...es within the range of 6dB 18dB OFF The gain is fixed at 6dB DNR Digital Noise Reduction The background noise in the low light level decreases automatically as the level of gain changes 1 Please posit...

Page 17: ...on AUTO Low light level auto mode OFF The function does not operate Note When SHUTTER is in the manual mode SENS UP does not operate When AGC is turned off SENS UP does not operate 3 Please press the...

Page 18: ...input the camera ID appears on the monitor 1 Please position the arrow to point to CAMERA ID by using the UP or DOWN button 2 Please select ON by pressing the LEFT or RIGHT button Note If OFF is sele...

Page 19: ...the screen and press SET Please position the cursor above the letter you wish to correct and then move the cursor onto the letter you wish to choose and press the SETUP button 5 When a name has been c...

Page 20: ...se LL you can adjust the desired phase Press the SET button You can adjust the desired phase from 0 to 359 Note When the power frequency is 50Hz you can not use the line lock mode NTSC Models When the...

Page 21: ...el of observation by using SENSITIVITY mode Please press the SETUP button to save the changes and complete the setting PRIVACY This mode conceals the areas you do not wish to appear on the screen OFF...

Page 22: ...f the level goes up excessively however it may affect the video image and generate noise Please press the SETUP button The available range of level is 0 31 RESET Returns to the level which was set by...

Page 23: ...5 Hi z properly and check the terminals Please check if an auto iris lens is being used and adjust the brightness level There is a problem with the camera operation The camera surface is too hot and b...

Page 24: ...25 KHz Vertical 50 00 Hz Resolution Mehr als 540 TV Lines Video Output 1 0Vp p 75 Video0 714Vp p Sync0 286Vp p 1 0Vp p 75 Video0 7Vp pSync0 3Vp p S N Y Signal 50dB AGC Off Min Illumination 0Lux with I...