System Requirements

HDMI equipped source devices, connect with HDMI cables or 
DVI equipped source, connect with DVI to HDMI cables

HDMI equipped displays (TVs or monitors) or HDMI equipped 
AV receivers, connected with HDMI cables

Industry standard CAT5e/6/7 cables

HDBaseT™ Receivers (CH-506RX, CH-507RX or CH-1109RX)

Operation Controls
and Functions

                                          Front Panel

LCM:

Displays the setting information of each input and output 
setting.

POWER:

Press this button to power the device on/off. The LED will 
illuminate green when the power is on, red when it is in 'Standby' 
mode.

LOCK:

Press this button to lock all the buttons on the panel; press 
again to unlock. The LED will illuminate green when locked.

IR:

IR Receiver window (accepts the remote control signal of this 
device only) with IR frequency of 38
kHz.

MENU:

Press this button to access the LCM menu system, from 
here EDID settings can be managed and IP system settings are 
displayed.

1~8/A~H and OUT/IN:

Press the OUT or IN button to select the 
output or input mode and then press the required number button 
to make the selection accordingly.
For example, if outputs A~D need to be set to input 1 and outputs 

Summary of Contents for 986

Page 1: ...8 8 HDMI over Single CAT5e 6 7 Matrix with PoE ID 986 Operation Manual ...

Page 2: ...ay s EDID settings Supports 3D signal display dependent upon the output display EDID settings Supports PoE Power over Ethernet on compatible receivers only Supports HDMI input up to 15 meters at 8 bit resolution or 10 meters at 12 bit resolution Supports bi directional IR to and from input and output locations Supports control via RS 232 IR remote on panel buttons and IP Telnet Web GUI 2U size des...

Page 3: ...n off The LED will illuminate green when the power is on red when it is in Standby mode 3 LOCK Press this button to lock all the buttons on the panel press again to unlock The LED will illuminate green when locked 4 IR IR Receiver window accepts the remote control signal of this device only with IR frequency of 38 kHz 5 MENU Press this button to access the LCM menu system from here EDID settings c...

Page 4: ...s please refer to Section 6 7 for a list of commands 3 ALL IR OUT Connect to the IR blaster for IR signal transmission to the source devices Place the IR blaster in direct line of sight of the equipment to be controlled All signals received from the display side will be relayed to the source devices 4 ALL IR IN Connect to the IR extender for IR signal reception Ensure that the remote being used is...

Page 5: ...eiver s LAN port 9 HDMI IN 1 8 Connect to the HDMI source devices such as a DVD player or a Set top Box with HDMI cables or DVI to HDMI cables 10 DC 24V Connect the 24 V DC power supply to the unit and plug the adaptor into an AC outlet 11 PoE 24V Connect the 24V PoE power supply into the unit and plug the adaptor into an AC outlet This unit will mainly power PoE Power over Ethernet capable receiv...

Page 6: ...button to switch the device ON or set it to standby mode 2 IN Input selection 1 8 3 OUT Output selection A H Note When the IR remote is used in the Output Zone the user only needs to select the desired input 1 8 IR Cable PIN Assignments ...

Page 7: ...et Commands COMMAND DESCRIPTION A1 A8 Switch Output A to 1 8 B1 B8 Switch Output B to 1 8 C1 C8 Switch Output C to 1 8 D1 D8 Switch Output D to 1 8 E1 E8 Switch Output E to 1 8 F1 F8 Switch Output F to 1 8 G1 G8 Switch Output G to 1 8 H1 H8 Switch Output H to 1 8 ABCD 1 ABCD 8 Switch Output ABCD to 1 8 at the same time SETIP IP SubNet GW Setting IP SubNet GateWay Static IP RSTIP IP configuration w...

Page 8: ...ted 3 The TV EDID setting will always follow output port 1 s EDID setting regardless of the output change 4 EDID setting switching will execute immediately Telnet Control Before attempting to use the telnet control please ensure that both the Matrix via the LAN CONTROL port and the PC Laptop are connected to the same active networks To access the telnet control in Windows 7 click on the Start menu...

Page 9: ... into the device which we wish to control Type HELP to list the available commands Type IPCONFIG To show all IP configurations To reset the IP type RSTIP and to use a set static IP type SETIP For a full list of commands see Page 7 Note Commands will not be executed unless followed by a carriage return Commands are not case sensitive If the unit s IP is changed then the IP Address required for Teln...

Page 10: ...ice s status control and User setting pages Click on the Control tab to control power input output ports EDID and reset mode Clicking on the User Setting tab allows you to reset the IP configuration The system will ask for a reboot of the device when any of the settings are changed The IP address needed to access the Web GUI control will also need to be changed accordingly on the web address entry...

Page 11: ...ANGE PIXEL CLOCK RATE VIDEO DATA RATE SUPPORTED VIDEO CAT5e 6 7 100m 225 MHz 5 3 Gbps HD Video Up to 1080p 60 Hz 36 bits 3D data rates lower than 5 3 Gbps or below 225 MHz TMDS clock 70m 225 MHz 5 3 Gbps Ultra HD Video 4K 2K 30 Hz video formats ...

Page 12: ...I Input Cable Length 15m 1080p 8 bit 10m 1080p 12 bit Audio Sampling Rate Up to 192 kHz ESD Protection Human body Model 8kV Air gap discharge 4kV Contact discharge Power Supply 2x24V 6 25A DC US EU standards CE FCC UL certified Dimensions 438mm W 255mm D 93mm H Weight 4458g Chassis Material Metal Color Black Operating Temperature 0 ºC 40 ºC 32 ºF 104 ºF Storage Temperature 20 ºC 60 ºC 4 ºF 140 ºF ...

Page 13: ......

Reviews: