Quick Start Guide
2
RFID ANTENNA CONNECTION: Connect RFID
antenna with wrench (8mm torque with 100 N-cm)
to reader (CS463 has 4 available RFID antenna ports
from port 1 to port 4).
WIFI + BLUETOOTH ANTENNA: Connect two
Wi Fi/BT antennas to reader as shown below.
3
ETHERNET CABLE: Connect Ethernet cable
to reader as below.
CS463 is set to Ethernet Static IP of 192.168.25.160 ex-factory. Wi Fi is
disabled ex-factory. This is to simplify the out-of-box experience.
4
WiFi Antenna
BT Antenna
Connecting to CS463 using Browser
Set your PC to a static IP of
192.168.25.100
(or any other as long as
the subnet is 25.
1
Connect Ethernet cable from your PC to CS463 directly, or via an
Ethernet switch.
2
Power up the CS463, wait 2.5 minutes.
3
You will see a User Login page.
Key in
User Name:
root
,
Password:
csl
then click
“Login”
to login to the system
5
You will see a Status page.
6
Default Access Mode is HTTP/XML. Change the Access
Mode if reader not in HTTP/XML mode
In order to read and show RFID tags in Web page,
change the Access Mode to “HTTP/XML” as
shown below in the system page.
Click “Set” to confirm the change.
6
Open Google Chrome browser on your PC, and type in
192.168.25.160
.
(Note that the Microsoft Edge Browser does not allow numeric based
addressing and therefore cannot be used here
. Firefox allows numeric
based addressing. In summary, one can use either Chrome, Internet
Explorer or Firefox).
4