3 Data format
For SerialPort1 in Resultant Action, Trusted Server data format is used.
cmd=evtNtf&evt_id=DemoEvent&src_ip=192.168.25.224&ant=Antenna1&cp_id=CapturePoint1&
idx=A3&tag_id=100000000000000000000004&rssi=-35&time=1222650380&cnt=1&bank1=&fre
q=875&PC=3000&usec=158663
cmd=evtNtf&evt_id=DemoEvent&src_ip=192.168.25.224&ant=Antenna1&cp_id=CapturePoint1&
idx=A4&tag_id=100000000000000000000005&rssi=-35&time=1222650480&cnt=1&bank1=&fre
q=875&PC=3000&usec=100
For SerialPort1 (Simplified), the data format is shown below. The “$” is EPC start symbol. The “#”
is EPC end symbol.
$100000000000000000000004#$100000000000000000000005#