background image

8

3.6

Fan/pump not running

fast enough on low speed.

3.7 Pump drive belt faulty or
broken.

3.6.1 Check that supply voltage is up to correct level.

3.6.2 Fan and pump will pick up speed slightly as the
motor reaches normal operating temperature. Allow the
cooler to run for 30-60 minutes and check again. If there is
no improvement have the cooler checked by a service
agent.

3.7.1 Replace drive belt as shown on page 7.

4.1 Reservoir or Aspen
cooling pad dirty.

4.2 Water quality is poor.

4.1.1 Drain reservoir and fill the cooler with clean water. If
it still smells clean the reservoir and replace the Aspen
cooling pad or proceed to 4.2.1.

4.2.1 Add a little vanilla essence or perfume to the water.

4. Cooler makes bad
smell.

5.1 Dirt has accumulated
inside pump.

5.1.1 Proceed as in 3.5.1

5.1.2 Replace drive belt as shown on page 7.

5 .

C o o l e r

m a k e s

scraping or rattling noise
on new season start up.

6.1

Too much water in

reservoir.

6.2 Water level indicator not
working.

6.1.1 Drain some water out (see page 7).

6.2.1

Remove the rear panel for access. Slide the

indicator up to the 'FULL' position then let it drop. If it fails
to operate have it checked by a service agent.

6. Water overflows from
reservoir.

7.1 Electrical fault.

7.1.1 Electrical parts must only be repaired and replaced
by Authorised Service Agents.

7. Cooler will not
operate at all.

8.1.1

If the power supply cord of this appliance is

damaged it must be replaced. Electrical parts must only
be repaired and replaced by Authorised Service Agents.

8. Damaged power
supply cord.

3. No cooling.

3.1 Cooling control is off.

3.2 Reservoir is empty or
nearly empty.

3.3 Weather is too humid.

3.4 Aspen cooling pad and /
or pump inlet screen blocked
or dirty.

3.5

Pump is not working

properly.

3.1.1 Turn cool knob to 'COOL'.

3.2.1 Fill with water again until water level indicator is at
the 'FULL' position. Water capacity is 14 litres

3.3.1 Turn cool knob to '0' and use cooler as a fan only.

3.4.1 Clean parts - see maintenance page 7.

3.5.1 The pump is NOT a separate electric pump. It is
connected to the fan motor and is driven mechanically.
Turn the cooler off and completely drain the reservoir.
Refill with water. Switch fan knob to high speed (3), turn
the cool knob to 'COOL',run the cooler for 10-15 minutes
non-stop. This will help dissolve and flush out the dirt. The
Aspen cooling pad should now be wet. If the pad is not
visibly wet and there is no cooling, have the cooler
checked by a service agent.

1. Cooler will not operate
at first.

2. Cooler stops operating
after running for some
time.

1.1 Power outlet or supply
faulty.

2.1

Motor overheated

(safety cutout).

1.1.1 Switch on power outlet.
1.1.2 Check power supply.
1.1.3 Check power outlet.

1.2.1 Check that power supply is the same as specified
on the rating label.

2.1.1 Wait 30-45 minutes for motor to cool down and it will
restart automatically. If condition persists take the cooler
to a service agent.

TROUBLESHOOTING

CONDITION

POSSIBLE CAUSE

REMEDY

Summary of Contents for MASTERCOOL

Page 1: ...OWNERS INSTRUCTION MANUAL C O O L A I R A N Y W H E R E MILLENIA P O R T A B L E N A T U R A L A I R C O N D I T I O N E R S by MEGACOOL MASTERCOOL ...

Page 2: ...pervision Young children should be supervised to ensure that they do not play with the appliance ILL863 A 3 MI MILLENIA ILL863 A 1 MIV MEGACOOL ILL1222 A 2 MIC MASTERCOOL Waste electrical products must not be disposed of with household waste This product should be taken to your local recycling centre for safe treatment As the policy of this company is one of continuous improvement all specificatio...

Page 3: ...ion control Safety instructions Cleaning the cooler rear panel removal To drain water Water strainer and Aspen cooling pad Pump belt replacement Drain Plug KEY Figs 4 5 A Controls B Front grille C Water filling door D Water reservoir E Castors F Water level indicator G Front pillar Millenia Megacool H Base I Rear panel retaining screws 2 J Rear panel K Power cord entry point L Reservoir drain plug...

Page 4: ...eel spring ring Fig 7 1 MODELS MILLENIA AND MEGACOOL ONLY Assemble the front and rear pillars and screw together Place this assembly on the base and slide into position until it locks Fig 8 ILL866 A 6 ILL867 B 7 ILL1221 A 8 ILL870 A 9 MODELS MILLENIA AND MEGACOOL ONLY Place the reservoir of the cooler onto the front pillar as shown Fig 9 Tilt downwards towards the rear until the reservoir locks on...

Page 5: ... the opposite side of the room for flow through ventilation This cooler will not cool properly in a closed room Fig 11 ILL1219 A 10 ILL871 A 11 ILL872 A 12 ILL873 B FULL EMPTY 13 FILLING WITH WATER Turn the cooler off before filling Open the water filling door and pour in clean water Fig 12 The water capacity is 14 litres The minimum amount of water needed for the pump to operate is 2 litres The c...

Page 6: ...ITIONING OF THE ASPEN COOLING PAD To get the best performance from your cooler we recommend that when first used it is run with water for at least 10 minutes at the setting in Fig 16 During this process the water becomes slightly yellow and there is a natural smell of damp wood This is normal AIR DIRECTION CONTROL MILLENIA MASTERCOOL The cooler is provided with air guide vanes which can be adjuste...

Page 7: ...rs CLEANING THE COOLER Important Always switch off and remove the electrical plug before cleaning and servicing the cooler To clean wipe the cooler with a damp cloth and a little household detergent The rear panel can be removed to gain access to inside the cooler by removing the screws at the top of each side Pivot the panel backwards and lift off Fig 20 ILL880 B 20 SAFETYINSTRUCTIONS As this coo...

Page 8: ... When the cooler is empty replace the plug in the tank Fig 21 ILL879 A 21 A B A ILL882 B 22 PUMPBELT REPLACEMENT If a pump drive belt needs replacing access can be gained by using a tool screwdriver to remove the small access door Fig 22 A Each cooler is supplied with a spare drain plug located in the position shown Fig 22 B SPARE DRAIN PLUG WATER STRAINER AND ASPEN COOLING PAD Clean the water str...

Page 9: ...ly cord of this appliance is damaged it must be replaced Electrical parts must only be repaired and replaced byAuthorised ServiceAgents 8 Damaged power supply cord 3 No cooling 3 1 Cooling control is off 3 2 Reservoir is empty or nearly empty 3 3 Weather is too humid 3 4 Aspen cooling pad and or pump inlet screen blocked or dirty 3 5 Pump is not working properly 3 1 1 Turn cool knob to COOL 3 2 1 ...

Page 10: ... Valve Assembly 20 20 1 Switch 2006 Millenia Mastercool Switch 2006 Megacool 22 Lever Vane 23 Vane Link RH 24 Vane Link LH 25 Vane 26 Vane Bearing 27 Vane Link Motor Millenia Megacool Millenia Megacool only Mastercool only Item Description 28 Pad Clamp 29 Water Level Indicator 30 Float Assembly 31 Pump Assembly 32 Strainer 33 Vane Motor 34 Vane Motor Hub 36 Fan Pulley 37 Fan 38 Drive Belt BS165 EP...

Page 11: ...uous improvement all specifications are subject to change without notice 7 29 30 1 2 5 26 25 24 41 39 19 18 1 18 16 20 44 17 43 42 36 4 3 10 11 38 9 32 31 37 14 13 15 23 27 33 34 46 47 12 28 Millenia Megacool Mastercool 8 22 6 12 ILL1432 A 0609 10 ...

Reviews: