HELP

PROBLEM

Inadequate
Cooling.

No air flow.

Air flow, but not cool.

Fan stops and then
restarts.

Continuous overflow of
water.

SUGGESTED REMEDY

Check that the tap is turned on. Check
pump and pump strainer. Check water
distribution systems. Ensure pump
(COOL) is turned on.

Adjust door / window opening.

Tease the woodwool out evenly or
replace pads.

Call Dealer to investigate and rectify.

Clean or replace pads.

Replace the fuse specific to that unit.
(See Installation Manual).

Replace belt.

Call Service (see Rear Cover).

Ensure water supply to unit is turned on.
Clean pump strainer.
Call Service to repair.

The fan motor is fitted with an automatic
thermal overload protector which will be
reset when the motor cools down. If the
motor stops and starts continuously, it
should be investigated for a fault by a
qualified Technician.

Adjust float valve.
Adjust bleed rate. Included on each
bleed tray are plastic plugs with matching
holes. With all plugs inserted, bleed rate
is maximum. If you decide that the
amount of bleed is too much, remove the
plug/s from the bleed tray one at a time
until the desired amount is achieved.

Clean seat, if it persists, call your dealer.

POSSIBLE CAUSE

Dry pads, or lack of water while air
conditioner operating.

Insufficient air discharge openings to
allow air to exhaust from areas being
cooled.

Pads shrunk away from the top corners
(woodwool pads only).

Air restriction in ductwork.

Clogged or Dirty Filter pads.

Circuit breaker tripped or unit fuse
blown.

Broken fan belt

Electrical fault.

Insufficient water reaching filter pads.

Pump failure.

Motor overload.

Float valve adjustment.
Incorrect bleed rate.

Drain valve leak (where fitted).
High salinity of supply water
(

only).

WATERmanager

TM

t will not take long for you to get to know the features of your air conditioner, but in case you
encounter difficulties here are a few hints to help keep you cool:

NOTE: For Homemaker, Harmony and Horizon (remote control) units refer to separate Operating
Instructions.

Summary of Contents for EA70

Page 1: ...AIR CONDITIONERS How to Operate Using Your Air Conditioner Getting the Best Results Help Warranty Installation Report Service Please keep these instructions for future reference IMPORTANT OWNER MATERI...

Page 2: ...ch or variable knob select the fan speed you require When ventilation only is required air flow with no cooling turn the COOL switch off and select the fan speed to provide the air flow you require Sw...

Page 3: ...nt filter pads a small amount of water is drained off from the system The continuous drain of small amounts of water ensures that fresh water is added to UNIT AREA m 2 dilute any build up of scale or...

Page 4: ...Turn off the water supply 2 Turn off the power supply 3 Remove the filter pad frames EX Units EA Units do not use excess water pressure as this may create holes in the pad material Instructions conti...

Page 5: ...move pump dismantle base clean and reassemble Do not replace this item until next season Do not lose the O ring seal During the Winter Months EX models Other Models Local Regulations Are fitted with a...

Page 6: ...ay are plastic plugs with matching holes With all plugs inserted bleed rate is maximum If you decide that the amount of bleed is too much remove the plug s from the bleed tray one at a time until the...

Page 7: ...ad frames Pump runs and water evenly distributed to all filter pads Bleed rate adjusted to lt min All control functions checked Owner instructed in correct operating procedure Owners Name Telephone Ad...

Page 8: ...e policy of Seeley International to introduce continual product improvement Accordingly specifications are subject to change without notice Please consult with your dealer to confirm the specification...

Reviews: