Contura C i6 Installation Instruction Download Page 4

465

505

405

320

180

330

Ø125

Air inlet Ø65

400

380

Ø125

590

660

330

595

295

170

Air inlet Ø65

C i6

545

625

GB

100

Type approved in accordance with:
European standard EN-13229 (DE/A), 
DINplus,
Part 15a B-VG in accordance with test 
report
RRF- 29 12 3029
Norwegian standard, SINTEF 110-0391
Type approved in SE in accordance with 
SITAC xxx

Flue connection - Rear

Flue connection - Top

Output  

  3-7 kW

Nominal output     5 kW
Efficiency 

  78 %

Weight (kg)  

  80

Width (mm)  

  595

Depth (mm)  

  405

Height (mm)  

  505

FACTS

Dimensions

Technical details

Cast iron front 

Connection dimensions

Glass front

Important to remember!

Installation by authorised 
technician 

This manual contains instructions about 
how the insert must be assembled and 
installed. To ensure the function and safety 
of the insert, we recommend that the 
installation is carried out by an authorised 
technician. Contact one of our dealers who 
can recommend suitable fitters.

Building permission

Before installing a stove or erecting a 
chimney, it is necessary for you to make an 
application for building permission to your 
local authority. Ask your local authority for 
advice regarding building regulations and 
the application.

Structural support

Check that the wood joists are strong 
enough to bear the weight of the stove and 
chimney. The stove and chimney can usually 
be placed on a normal wooden joist in a 
single occupancy house, if the total weight 
does not exceed 400 kg.

Hearth plate

Due to the risk of falling embers, a 
flammable floor must be protected by 
a hearth plate. The hearth plate must 
extend 300mm in front of the hearth and 
can consist of natural stone, concrete, 
metal or glass. 

The minimum distance in front of the 
hearth to combustible parts of the building 
or interior decoration must be at least 1 
metre.

Summary of Contents for C i6

Page 1: ...www contura eu C i6 Installation instruction Lighting instructions...

Page 2: ...F 29 12 3029 The undersigned is responsible for the manufacture and conformity with the declared performance Niklas Gunnarsson Business area manager NIBE STOVES Markaryd 1st July 2013 DECLARED PERFORM...

Page 3: ...gular chimney sweeping services WARNING The insert becomes very hot During operation certain surfaces of the insert become very hot and can cause burn injury if touched Also take heed of the strong he...

Page 4: ...the installation is carried out by an authorised technician Contact one of our dealers who can recommend suitable fitters Building permission Before installing a stove or erecting a chimney it is nec...

Page 5: ...ter diameter is 125 mm The insert requires a draft in the chimney of at least 12 Pa The draft is affected both by the length and area of the chimney and by how well sealed it is The minimum recommende...

Page 6: ...The weight of the chimney must not load the insert with more than 100 kg The base must not prevent the convection air flow in the area between insert and recess Recessing the insert When recessing th...

Page 7: ...earing base The dimensions are the minimum dimensions unless otherwise stated Wall of non combustible material that is not in contact with combustible material and therefore has no minimum thickness r...

Page 8: ...ATION The insert is designed to be installed as a stove cassette in existing approved open hearths There must be an 8 mm air gap around the insert to allow for the expansion of the insert when hot Ins...

Page 9: ...2 1 3 GB 105 Hearth bottom Hearth cladding Fire bars Remove internal loose cast iron components and fire bricks as follows INSTAllATION Removing the internal parts Handle the hearth cladding with care...

Page 10: ...4 5 1 2 3 GB 106 INSTAllATION Then remove the insert from the convection box...

Page 11: ...ase of installation sold as an accessory Secure the sleeve in the hose Connect and seal carefully between the hose and the chimney according to the separate instruction The insert can also be connecte...

Page 12: ...x6 LE K 6 mm 1 2 3 GB 108 INSTAllATION...

Page 13: ...tallation is inspected by an authorised inspection body before the insert is used Also read the Lighting instructions before lighting for the first time Final inspection of the installation Reinstall...

Page 14: ...air can be reduced The nominal output of 5 kW is obtained when the combus tion air damper is 50 open and two logs are lit In this operating position it is important that the air intake damper is fully...

Page 15: ...nt or a special soot removal agent to remove it Such agents can be purchased from regular hardware stores or from your local stove dealer Never use cleaning agents that contain any abrasives these can...

Page 16: ...content of the wood ensure that you have good base embers and go through the lighting instructions one more time Smoke odour around the insert for periods This can occur when wind blows down the chimn...

Reviews: