Contura C i51A Installation Instruction Download Page 11

90°

1

GB

123

Assembling the stand

x 6
Spacers

x 6
M5 x 20
Allen screw 4

STAND ASSEMBLY

Summary of Contents for C i51A

Page 1: ...C i5AN C i51A C i51T C i51S www contura eu Installation instruction ...

Page 2: ... The undersigned is responsible for the manufacture and conformity with the declared performance Niklas Gunnarsson Business area manager NIBE STOVES Markaryd August 21 2015 DECLARED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material 0 mm to rear 700 mm to side According to the given conditions in the ...

Page 3: ...he installation of a stove to your local authority The owner of the house is personally responsible for ensuring compliance with the mandatory safety requirements and must have the installation approved by a qualified inspector Your local chimney sweep must also be informed about the installation as this will affect the routines for regular chimney sweeping services A warm welcome to Contura A war...

Page 4: ...protected by a firewall or by the integrated protective screen which is available as an option in some markets The following material requirements are made of the firewall The building material must not be combustible The thermal conductivity coefficient λ must be a maximum of 0 14 W mK The thickness of the building material must always be at least 100 mm In cases where the building material s ins...

Page 5: ...nd edges The stone is a natural material which means that there may be certain irregularities and variations in its appearance Clean the stone with a damp cloth Soapy water can be used if necessary To avoid abnormally large gaps and uneven lines it is important that the stove and steel stand are straight and stable Adjust and align it carefully before hanging the stone During assembly check that a...

Page 6: ... connection is Ø150 mm The insert requires a draft in the chimney of at least 12 Pa The draft is affected both by the length and area of the chimney and by how well sealed it is Minimum recommended chimney length is 3 5 m and a suitable cross sectional area is 150 200 cm2 Ø140 160 mm Note that a flue with sharp bends and horizontal routing reduces the draught in the chimney The maximum horizontal ...

Page 7: ...ced The amount of combustion air that is used for combustion is approx 25 m3 h Some installation alternatives are shown below The air duct connection on the stove has an external diameter of Ø100 mm Turn the connector to ensure an air supply In hot areas the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor aluminium tape It is important that the lead in between th...

Page 8: ...in some markets or an external firewall that protects the wall behind is required Material requirements for firewalls according to the section Walls behind on page 116 Important The dimension diagrams only show the minimum permitted installation distances for the stove When connecting to a steel flue also note the safety distance requirements of the flue The minimum distance to combustible parts o...

Page 9: ...edge of the floor section will align with the complete rear edge of the surround If the protective screen is selected read these instructions before installing the insert or chimney The stove can be positioned tight to the wall behind When installing against non vertical walls and to facilitate installation it is recommended that a small gap is left between the wall and stove Lay the floor section...

Page 10: ...illustrated and adjust the rear feet until the stove is level Place a spirit level on the moulding below the door and adjust the front feet to the specified measurement from the floor to the moulding s lower edge and until the spirit level is straight Check that the transport locking device of the counterweight is removed according to the insert instructions before assembling the surround ...

Page 11: ...90 1 GB 123 Assembling the stand x 6 Spacers x 6 M5 x 20 Allen screw 4 STAND ASSEMBLY ...

Page 12: ...13 13 VANADI UM No 7 CHROME 2 13 mm 13 mm GB 124 STAND ASSEMBLY ...

Page 13: ...3 4 GB 125 x 16 M5 x 9 T25 STAND ASSEMBLY ...

Page 14: ...e screen as option now install according to separate instructions Ensure that the disc base can be pushed around the stand Adjust the base height with the rubber feet On heavily sloping floors the insert and stand may need to be raised further Then reposition the base until all stones are in place Check that there is a 30 mm gap all the way between the rear of the stand and wall behind x 8 M4 x 6 ...

Page 15: ...2 1 3 GB 127 The stone must lie flush against the stand Place a foam sheet on the floor to prevent the stone corners from becoming damaged when handling Installation of surround INSTALLATION OF SURROUND ...

Page 16: ...4 This panel can be removed for servicing Lock it in place by inserting a screw through the moving catch in the front panel Do not tighten the screw it must be possible to move the catch upwards to detach the panel INSTALLATION OF SURROUND ...

Page 17: ...7 8 9 10 GB 129 x 3 M6 x 25 Allen screw 4 x 4 M6 x 25 Allen screw 4 x 4 M6 x 12 Allen screw 4 INSTALLATION OF SURROUND ...

Page 18: ...11 1 mm 410 mm 12 13 GB 130 INSTALLATION OF SURROUND Allen screw 4 ...

Page 19: ...15 14 16 GB 131 INSTALLATION OF SURROUND Allen screw 4 ...

Page 20: ...1 2 GB 132 x 2 M6 x 10 Allen screw 4 For rear connection Assembling grate and top INSTALLING GRATE AND TOP ...

Page 21: ...3 25 mm 4 GB 133 INSTALLING GRATE AND TOP ...

Page 22: ...2 1 GB 134 x 2 M6 x 10 Allen screw 4 INSTALLING GRATE AND TOP For top connection ...

Page 23: ...x 5 x 4 x 8 3 4 GB 135 INSTALLING GRATE AND TOP ...

Page 24: ... 25 mm 5 1 GB 136 Disc base INSTALLING GRATE AND TOP ...

Page 25: ...tant that the installation is inspected by an authorised inspection body before the stove is used Also read the Lighting instructions before lighting for the first time INSTALLING GRATE AND TOP Adjust the rubber feet on the disc base so that the gap up to the stone is 5 mm ...

Page 26: ......

Page 27: ......

Page 28: ...IBE AB Box 134 SE 285 23 Markaryd Sweden www contura eu Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice The current edition can be downloaded from www contura eu ...