Contura C i50 Operation Instructions Manual Download Page 10

GB

58

Lighting Instructions

refuelling on to a low fire bed: 

If there is insufficient burning material in the firebed to light a new fuel 
charge, excessive smoke emission can occur. Refuelling must be carried 
out onto a sufficient quantity of glowing embers and ash that the new fuel 
charge will ignite in a reasonable period. If there are too few embers in the 
fire bed, add suitable kindling to prevent excessive smoke.

Fuel overloading:

The maximum amount of fuel specified in this manual should not be ex-
ceeded, overloading can cause excess smoke.

operation with door left open:

Operation with the door open can cause excess smoke. The appliance must 
not be operated with the appliance door left open except as directed in the 
instructions.

dampers left open

Operation with the air controls or appliance dampers open can cause excess 
smoke. The appliance must not be operated with air controls, appliance 
dampers or door left open except as directed in the instructions.

aerosol sprays

Do not use an aerosol spray on or near the stove when it is alight.

Use of operating tools

Always use the operating tools provided when handling parts likely to be hot 
when the stove is in use.

Chimney Fires

If the chimney is thoroughly and regularly swept, chimney fires should not 
occur.  However, if a chimney fire does occur turn off the stove immediately 
and isolate the mains electricity supply (if applicable), and tightly close the 
doors of the stove.  This should cause the chimney fire to go out. If the 
chimney fire does not go out when the above action is taken then the fire 
brigade should be called immediately. Do not relight the stove until the 
chimney and flueway have been cleaned and examined by a professional.

Permanent air vent

The stove requires a permanent and adequate air supply in order for it to 
operate safely and efficiently.
In accordance with current Building Regulations the installer may have fit-
ted a permanent air supply vent into the room in which the stove is installed 
to provide combustion air. This air vent should not under any circumstances 
be shut off or sealed.

USer oPeraTinG inSTrUCTionS

Please read the important notices given above before referring to the main 
instruction book for detailed operating instructions.

recommended fuels:

Please note that HETAS Ltd Appliance Approval only covers the use of wood 
logs on this appliance.  HETAS Ltd Approval does not cover the use of other 
fuels either alone or mixed with the recommended fuels listed above, nor 
does it cover instructions for the use of other fuels. The stoves have a 
refuelling interval of 0.75h to achieve the nominal rated output. Wood logs 
should be seasoned with a moisture content of around 20%. 

Summary of Contents for C i50

Page 1: ...Ci50 Ci51 www contura eu Operation instructions...

Page 2: ...e the window open for a few minutes until the fire has caught properly 1 Open the damper completely to max 2 The start up fire must consist of approx 11 pieces of kindling of varying dimensions with a...

Page 3: ...op 3 The damper must be completely open until the logs turn black and catch fire This can take about 3 5 min The damper can then be closed The conditions for controlling combustion vary depending on t...

Page 4: ...insulating properties It contains a certain amount of water that evaporates during the first lighting Whilst this happens combustion may seem to be slow and soot may build up on the insulation panels...

Page 5: ...ustion is also poor layers of soot and tar build up in the chimney and could at worst lead to a chimney fire In addition it causes the glass of the insert to soot and may cause discomfort to those liv...

Page 6: ...traight up The ash must be stored in a fireproof container with a lid for at least one week before being disposed of The grate and other cast iron components can be cleaned using a wirebrush It is imp...

Page 7: ...installation of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s instructions Provision of an alarm must not be considered a substitute for either installi...

Page 8: ...modate the weight of the stove and its chimney if the chimney is not independently supported The weight of the stove is indicated in the brochure The stove should preferably be installed on a non comb...

Page 9: ...ns given under Warning Note above Air Controls Manually operated air control can be managed by adjusting the air control valve to increase decrease the air flow to the stove Use of fireguard When usin...

Page 10: ...himney fires should not occur However if a chimney fire does occur turn off the stove immediately and isolate the mains electricity supply if applicable and tightly close the doors of the stove This s...

Page 11: ...going Check that the combustion air damper is open fully Check that the ash box is not overfilled An overfilled ash box will block parts of the fireplace s air supply After sweeping the smoke outlet o...

Page 12: ...to property and personal injury The ash pan must be emptied when it is full If this is not done the air supply can become blocked resulting in poor function In serious cases ash can find its way out t...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...E AB Box 134 285 23 Markaryd Sweden www contura eu Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice The current edition...

Reviews: