CHIMNEY

Connection to chimney

Ø 

ca 180 mm

Ø 

ca 180 mm

Rear connection to a masonry chimney

Top connection to the chimney

Make sure that the connector 
gasket does not work loose when 
the connection pipe is placed 
on the connector. If further 
sealing material is required, heat-
resistant sealant may be used. 

The back panel must be installed before the stove is rear connected.

The hot air grille must be installed before chimney top 
connection. 

•  The stove meets the requirements for connecting to chimneys 

dimensioned for 350°C flue gas temperature. 

•  The external diameter of the connection sleeve is 150 mm. 
•  The stove requires a draft in the chimney of at least –12 Pa. The 

draft is affected both by the length and area of the chimney, and 
by how well sealed it is. Minimum recommended chimney length 
is 3.5 m and suitable cross section area is 150-200 cm² (140-160 
mm in diameter). 

•  A flue with sharp bends and horizontal routing reduces the 

draught in the chimney. Maximum horizontal flue is 1 m, on the 
condition that the vertical flue length is at least 5 m. 

•  It must be possible to sweep the full length of the flue and the 

soot hatches must be easily accessible.

•  Carefully check that the chimney is sealed and that there is no 

leakage around soot hatches and flue connections.

2

3

1

5

6

4

!

In the bag with these installation instructions
are two wing screws for the cover.

Summary of Contents for C 820T

Page 1: ...Installation Instructions C 820T www contura eu...

Page 2: ...s one aspect of our vision to be a company of the future setting high quality standards regarding the environment Certification number 378 001 CERTIFICATE www contura eu EC Declaration of conformity M...

Page 3: ...o best light your stove in the lighting instructions The stove becomes very hot During operation certain surfaces of the stove become very hot and can cause burn injury if touched Be aware of the stro...

Page 4: ...tion These main instructions may give guidance which would contravene national building regulations Please refer to supplementary instructions or ask your local authority for advice regarding building...

Page 5: ...ection sleeve is 150 mm The stove requires a draft in the chimney of at least 12 Pa The draft is affected both by the length and area of the chimney and by how well sealed it is Minimum recommended ch...

Page 6: ...nt must be selected In hot areas the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor plastic It is important that the lead in between the pipe and the wall or floor...

Page 7: ...of the flue The safety distance between an un insulated flue and a combustible part of the building should be at least 450 mm Installation distances WHEN INSTALLING TURNTABLE OPTION the following ins...

Page 8: ...inspection of the installation It is extremely important that the installation is inspected by an authorised chimney sweep before the stove is used Also read the Lighting instructions before lighting...

Page 9: ...GB 57 ASSEMBLY 5 7 6 8...

Page 10: ...GB 58 4 6 5 ASSEMBLY...

Page 11: ...w to remove the fire bricks Handle the vermiculite with care Lift the smoke baffle with one hand whilst removing the sides The side posts need not be removed when sweeping Reinstall in reverse order 2...

Page 12: ...Contura reserves the right to change colours materials dimensions and models at any time without special notice Your dealer can give you the most up to date information Stoves shown in brochures may...

Reviews: