C 685
72
GB
615
300
70
750
800
800
Fire-retardant wall of
brick or concrete
800
520
250
100
100
200
300
400
175
275
375
475
Combustible wall
400
700
1200
120* (520)
200
50
Fire-retardant wall of
brick or concrete
640
325
95
785
Combustible wall
D 360
E 1060
B 1060
A 1190
C 400
220
480
40
Air inlet Ø64
Ø150
2100
555
1260
Ø580
Air inlet Ø64
Combustible roof
* If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate. Also applies to
separate
glass hearth plates (accessory).
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
The minimum distance in front of
the stove opening to combustible
parts of the building or interior
decoration must be at least 1 m.
When top connecting a steel flue,
please refer to the particular
manufacturer's installation
instructions. Observe the safety
distance to combustible material
required by the steel flue
Installation distances
WHEN INSTALLING TURNTABLE (OPTION)
the
following installation distances do not apply.
See the separate turntable installation instruc-
tions.
A = height from floor to chimney
connection upwards
B = height from floor to c/c chimney
connection rear
C = height from floor to air inlet
D = height from floor to lower edge
of hatch
E = height from floor to upper edge
of hatch
A separate glass hearth
plate (accessory)
increases the connection
height to the chimney
by 10 mm. The spacers
supplied with the hearth
plate are installed on the
stove before connection.
INSTALLATION DISTANCES
Permitted
area for
combustible
parts of the
building