57
GB
Top flue connection to a chimney
When installing the chimney, please refer to the manufacturer’s installation instructions.
Below we explain how to connect the chimney to the stove.
Top flue connection
Slide the flue base over the collar. Make sure that the seal round
the collar is not dislodged. If further sealing material is required,
heat-resistant sealant may be used.
Fit the connecting sleeve between the stove and the flue collar
in the wall. Make sure that the gasket does not work loose from
its position. Seal the joint between sleeve and collar with sealing
rope, or use heat-resistant sealant for a tighter seal.
Rear flue connection to masonry chimney
Mark out the centre of the hole to be made in the wall for a rear flue connection. Check the height to make sure that the hole aligns
with the chimney connection on the rear of the stove.
Important!
When connecting the stove to a top flue, make sure you fit the
hot-air vent and the screen before the chimney.
LEK
LEK
Gäller ej!
Make a hole at least 180 mm in diameter and then secure the flue collar in place in the wall using heat-proof mortar (not supplied). Allow
the mortar to dry before connecting the stove to the flue.
Stoves are supplied from the factory ready for
connecting to a top flue. To prepare the stove for
connection to a rear flue, the connecting collar and
covering cap need to change places.
Use a hammer to tap out the punched metal cover
in the stove’s rear panel. Cut away the metal cover
in the heat reflector with side-cutting pliers.
In the bag with these installation instructions
are two wing screws for the cover.