Contura C 35T Installation Instruction Download Page 4

Eldstadsbeklädnad

Rosterreglage

Asklåda

Förbränningsluftsreglage

Brasbegränsare

HANDÖL

In accordance with standards below
marking was affixed:
European Standard:
SE Quality Certification, P-marked:
NO Standard NS 3059:
DE and AT Standard DIN 18.891 and
Art 15a B-VG:
Type:
Nominal Output:
Fuel:
Minimun draught:
Flue gas temerature:
Energy efficiency:
Emission of CO in cumbustion products:
Distance to cumbustible wall (mm):

Follow the user’s instructions and use only recomended fuel

NIBE AB Box 134 SE-285 23 MARKARYD SWEDEN

2007
EN 13240
Cert no 0112/07
SINTEF 110-0275

RRF-40 07 13 90

Handöl 31/31A/32/32A
5 kW
Wood
12 Pa
280°C
78%
0,14%
Behind 150
Beside 450 
Corner 150

HANDÖL

NIBE AB SE-85 21 Markaryd Sweden

Type:

Production no.

50-series
7090300236

84

GB

Effect 

3-7 kW

Nominal effect 

5 kW

Efficiency  

80 %

Model C35T

 

Weight (kg) 

250

Width (mm) 

550

Depth (mm) 

430

Height (mm) 

1600

Heat retaining stones (kg) 

70

Installation by authorised 
technician 

This manual contains instructions on 
how the stoves must be assembled and 
installed. To ensure the function and 
safety of the stove, we recommend that 
the installation be carried out by an 
authorised technician. Contact one of 
our dealers who can recommend suitable 
fitters. 

Building permission

Before installing a stove or erecting a 
chimney, it is necessary for you to make 
an application for building permission 
to your local authority. Ask your local 
authority for advice regarding building 
regulations and the application.

Structural support

Check that the wood joists are strong 
enough to bear the weight of the stove 
and chimney. The stove and chimney can 
usually be placed on a normal wooden 
joist in a single occupancy house, if the 
total weight does not exceed 400 kg.

Hearth plate

Due to the risk of embers falling out, a 
flammable floor must be protected by 
a hearth plate. It must extend 300 mm 
in front of the stove and 100 mm on 
each side of the stove, or have a 200 mm 
extension on each side of the opening. 
The hearth plate can consist of natural 
stone, concrete, metal plate or glass. 
A painted metal or glass hearth plate 
is available as an accessory for these 
models. 

Important to remember!

Technical details

Type approved in accordance with:
European standard EN-13240 
Swedish type approval,
P-marking cert. no. 0112/07
Norwegian standard NS 3059,
SINTEF 110-0275 
German standard DIN Plus,
RRF-40 09 1955

FACTS

Rating plate

Fire bars

Hearth cladding

Grate control

Combustion air control

Ash-pan

Summary of Contents for C 35T

Page 1: ...www contura eu C 35T Installation instruction...

Page 2: ...LARED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material 100 mm to rear 415 mm to side Other safety di...

Page 3: ...ion Read how to best light your stove in the lighting instructions NOTE Report the installation of a stove to your local authority The owner of the house is personally responsible for ensuring complia...

Page 4: ...an authorised technician Contact one of our dealers who can recommend suitable fitters Building permission Before installing a stove or erecting a chimney it is necessary for you to make an applicati...

Page 5: ...istances for the stove When connecting to a steel flue also note the safety distance requirements of the flue The safety distance between an un insulated flue and a combustible part of the building sh...

Page 6: ...the knockout using a hammer The air duct connector on the stove has an external diameter of 64 mm In hot areas the duct has to be insulated with 30 mm mineral wool covered with a moisture barrier pla...

Page 7: ...orce of the hatch can be adjusted by moving the spring between the three notches on the lever The angle of the stove also affects the closing force of the spring If the spring force seems weak despite...

Page 8: ...draft in the chimney of at least 12 Pa The draft is affected both by the length and area of the chimney and by how well sealed it is The minimum recommended chimney length is 3 5 m and suitable cross...

Page 9: ...s connected to the top Connection to chimney Sweeping When sweeping the smoke baffle must be removed on the Contura 30 series this can be done by lifting the smoke baffle and removing the side piece L...

Page 10: ...603653 F1603493 F2603656 F1 603436 F2 603652 F1 603487 F2 603651 90 GB Installation of surround INSTALLATION Do not tighten the screws The stones are numbered as illustrated above We recommend that th...

Page 11: ...4 6 5 10 10 VAN ADI UM No 7 CH RO M E 91 GB INSTALLATION...

Page 12: ...7 8 92 GB INSTALLATION If a fan is to be installed it has to be done before the lower front stone is put in place Check that the front stone is positioned level with the sides of the base plate...

Page 13: ...9 10 11 93 GB INSTALLATION...

Page 14: ...12 13 14 15 94 GB INSTALLATION Clean the inner and outer side glass before further installation Carefully insert the profile and glass and move down the groove...

Page 15: ...2 1 16 17 18 95 GB INSTALLATION...

Page 16: ...N Final inspection of the installation It is extremely important that the installation is inspected by an authorised chimney sweep before the stove is used Also read the Lighting instructions before l...

Page 17: ...1 3 2 97 GB INSTALLATION Installation of accessories Heat retaining stones Heat retaining stones to glass top...

Page 18: ...1 2 98 GB INSTALLATION Heat retaining stones to soapstone top...

Page 19: ...3 4 5 99 GB INSTALLATION...

Page 20: ...E AB Box 134 285 23 Markaryd Sweden www contura eu Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice The current edition...

Reviews: