CONTROLS, INCORPORATED
C O N T R O L S Y S T E M S & S O L U T I O N S
6
CONTROL PANEL INPUTS AND OUTPUTS
The panel has one analog input and up to one digital input available to monitor other components,
senders or signals. These inputs can be used for a number of purposes including alarms and shut
downs.
Input
Heading
Default
Options
Connector
Pin
Digital 1
Normally
Open
Open / Closed
A
4
Function
Alarm
Message
None
Check
Off
Off / Always / Run
Digital 2
Normally
Open
Open / Closed
B
1
Function
Pre Alarm
Message
Air Filter Service
Check
Off
Off / Always / Run
Digital 3
Normally
Open
Open / Closed
B
6
Function
Pre Alarm
Message
Trans. Oil Temp.
Check
Always
Off / Always / Run
Digital 4
Normally
Open
Open / Closed
B
3
Function
Pre Alarm
Message
Park Brake Active
Check
Always
Off / Always / Run
Digital 5
Normally
Open
Open / Closed
B
4
Function
Pre Alarm
Message
4 WD Active
Check
Always
Off / Always / Run
Digital Outputs
1)
Alarm – Engine shutdown when active with display message as assigned. A red lamp will also
be illuminated.
2)
Pre Alarm – Warning message will be displayed along with a yellow lamp when active.
3)
Pre Alarm & Alarm - Energizes an external audible alarm when a pre alarm or alarm condition
is present. Pressing the ENTER button will silence.
4)
Alarm Horn - Energizes an external audible alarm when an alarm condition is present.
Pressing the ENTER button will silence.
5)
Engine Run - Relay will be active when engine RPM is greater than 600. Typically used to
drive an auxiliary circuit such as louvers or send a signal to a monitoring station.