DIGITAL FUNCTIONS

 

The digital inputs can be configured for different uses depending on the application.  These 
include the following: 
1)

 

 Alarm – Engine shutdown once active with display message as assigned.  A red lamp will also 
be illuminated. 

2)

 

Pre Alarm – Warning message will be displayed along with a yellow lamp when active. 

3)

 

Soft Alarm – Recoverable Alarm. Engine will shut down as soon as this input is tripped, but 
will recover to running if the condition is cleared quickly enough.   

4)

 

Aux Throttle Up – Mimics the front panel key press for speed control.  

5)

 

Aux Throttle Down - Mimics the front panel key press for speed control. 

6)

 

Return to Idle – Engine will resume its pre-designated idle speed  

7)

 

Return to Operating Speed – Engine will return to its pre-designated operating speed 

8)

 

Hydro-Throttle - With the Throttle toggle in the automatic position, closing this input to 
ground will allow the engine to run at the last operating speed.  Opening the circuit will 
return the engine to idle. 

9)

 

High Float - For auto start applications where a single or dual float system is desired.  Note, 
Digital 1 Action must be configured for Auto Start. 

10)

 

Low Float – For auto start applications where a dual float system is desired.  Note, Digital 1 
Action must be configured for Auto Start. 
 

 
DIGITAL FUNCTION MONITORING

 

Off / Always / Run – Describes when the parameter will be monitored for alarm conditions.  Run 
refers to when the engine is running.  Off disables the alarm conditions.  Always enables the alarm 
constantly regardless of engine state. 

 
DIGITAL FUNCTION DELAYS

 

Alarm Delay – The time period, after Sender Check Bypass, that the parameter must be on the alarm   
condition before the alarm becomes latched. 

Summary of Contents for C4F-F10198

Page 1: ...198 12v System Revision 1 0 ______________________________________________________________________________________________________________________________________ Copyright Controls Inc P O Box 368 Sh...

Page 2: ...1 PIN ENGINE HARNESS CONNECTOR 4 PIN TERMINAL STRIP ENGINE ALARMS CODES AND MESSAGES 7 ENGINE ECU ALARMS DE RATE SHUT DOWNS PANEL ALARM ANNUNCIATION AND CODE READER PANEL INDICATION LAMPS ACTIVE AND S...

Page 3: ...Default 100 rpm sec Throttle Curve Selection Multistate Speed 1 Selection Multistate Speed 2 Selection Multistate Speed 3 Selection Multistate Speed 4 Selection Manual Throttle Options 1 Vernier Thro...

Page 4: ...un position 2 Engine Stop Turn key to off position 3 Engine Throttle Push up and down buttons Manual Throttle Control With the key in the RUN position the panel operates manually by pressing the up an...

Page 5: ...CONTROLS INCORPORATED C O N T R O L S Y S T E M S S O L U T I O N S 4 MODULE CONNECTORS Primary Connector 14 Pin...

Page 6: ...ommon 13 Analog 1 Input 7 J1939 High 14 Digital 1 Input SECONDARY CONNECTOR 23 Pin Pin Function Pin Function Pin Function 1 Relay 5 9 Relay 5 6 Common 16 Relay 6 2 N A 10 N A 17 Digital 2 3 N A 11 N A...

Page 7: ...D Crank Signal V J1939 High U J1939 Low J Alternator Excite L Analog Throttle Emulator M Analog Throttle Emulator C Analog Throttle Emulator R Digital Throttle Emulator S Digital Throttle Emulator P...

Page 8: ...s or shuts down the engine when it is not operating within normal parameters This includes more common shut downs like high engine temperature and low oil pressure but can encompass a large range of p...

Page 9: ...ity to check the engine ECU for all ACTIVE and STORED engine ECU codes These codes can be viewed via the Active Codes and Stored Codes menus In addition the control panel has its own Alarm Event Log m...

Page 10: ...ss Pre Alarm 15 0 100 PSI Low Oil Press Alarm 10 0 100 PSI Oil Press Alarm Delay 5 0 01 1 40 Sec Temperature Check Run Off Always Run Low Temp Pre Alarm 0 0 300 Deg F Low Temp Alarm 0 0 300 Deg F High...

Page 11: ...t Connector Pin Analog 1 Function Fuel Level Auxiliary 6 Digital 1 Function Auto Start Auxiliary 5 Digital 2 Normally Open Auxiliary 3 Function Alarm Message E Stop Check Always Digital 3 Normally Ope...

Page 12: ...ommon with battery negative 4 Oil Pressure bar Oil pressure in bar can be measured and displayed on the C3 module using a standard Stewart Warner scale sender of 240 ohms 33 ohms 240 0 bar and 33 7 ba...

Page 13: ...Operating Speed Engine will return to its pre designated operating speed 8 Hydro Throttle With the Throttle toggle in the automatic position closing this input to ground will allow the engine to run a...

Page 14: ...on Crank 21 Pin Connector D Polarity Positive Initial State Off Relays 5 8 Available RELAY FUNCTIONS Available relays can be assigned for different uses a None Assign to none when not used b Pre Alarm...

Page 15: ...t and while the engine is running Used to drive the engine s ECU circuit Also active when requesting active and stored J1939 codes m Custom 1 Reserved for OEM applications n Preheat Relay will be acti...

Page 16: ...croll menu options Press UP arrow button to enter menu Press DOWN arrow button to reverse Exit Menu System Hold MENU button and press ENTER button To Change a Setting Press ENTER button to bring up br...

Page 17: ...lt Codes View Scroll Stored Fault Codes Operation Event Log View Last 32 Events Start Stop Alarms Alarms Event Log View Last 32 Alarms Engine Parameters View ECU Engine Information Load Torque Oil Tem...

Page 18: ...ve Delay 2 Output Configuration Relay Output 1 Pre Set to Pre Alarm Relay Output 2 Pre Set to Fuel Run Relay Output 3 Pre Set to Alarm Relay Output 4 Pre Set to Crank Signal Relay Output 5 Setup Funct...

Page 19: ...rature Pre Alarm Selection Engine Temperature Alarm Selection Engine Temperature Alarm Time Delay Selection Battery Volt Check On Off Low Battery Volt Pre Alarm Selection High Battery Volt Pre Alarm S...

Page 20: ...TED C O N T R O L S Y S T E M S S O L U T I O N S 19 7 Emissions Configuration TSC Regen Speed Selection Allow Service Regen Yes No Deere Only Regen Interlock On Off TSC Transmit Yes No stop TSC to en...

Reviews: