Summary of Contents for CHLOR MAKER 10

Page 1: ...ControlOMatic Inc 13433 Lime Kiln Road Grass Valley CA 95949 www ControlOMatic com Support ControlOMatic com 530 205 4520 Manual Version 9 1 11 Made in the USA CHLORMAKER TM OPERATING INSTRUCTIONS...

Page 2: ...ground fault circuit interrupt or GFI ground fault interrupt protected 110 or 220 VAC power source only WARNING Protect the power supply and outlet from exposure to the elements including direct sun r...

Page 3: ...chemistry for portable spas PARAMETER RECOMMENDED LEVEL Free Chlorine 3 0 to 5 0 PPM PH Balance 7 2 to 7 6 Total Alkalinity 80 to 120 PPM Calcium Hardness 150 to 300 PPM It is recommended that chlori...

Page 4: ...t Mineral Enriched 1 8 2 9 Dead Sea Salt Coarse Grain Salt Mineral Enriched 2 5 5 0 99 Pure Sodium Bromide NaBr Fine Grain Salt 2 5 4 0 The amount of salt to add and dissolve is dependent upon the siz...

Page 5: ...roduct layout below 1 Prepare Spa For Installation Shut down main power to spa and drain water completely Open access panel to the spa exposing the spas plumbing and spa pack Open the access panel to...

Page 6: ...he continuous 24 Hour circu lating pump where the tube can be cut and reconnected to the cell The location should be visible to allow for inspection of the titanium plates through the clear part of th...

Page 7: ...power supply cable to the black power supply CAUTION Do not turn spa power on until the spa has been refilled with water and salt has fully dissolved Refer to DIAGRAM 3 9 Refill Spa Add Salt Recheck...

Page 8: ...r Spa Gallons 1 to 3 Less than 200 4 200 to 300 5 300 to 400 6 400 to 500 7 to 10 500 and above Test the Chlorine Level with test strips after 1 to 2 days When testing the best readings are always don...

Page 9: ...w ever there may be water conditions very hard water where the self cleaning design may not be able to keep up If this water condition exists in your area a white buildup will be visible on the titani...

Page 10: ...ain the usage of the system to the buyer repairs necessitated by use other than normal home use damage resulting from misuse unintended use unforeseen use non pool or spa use abuse accidents alteratio...

Page 11: ...CHLORMAKER TM Go To www ControlOMatic com For More Product Information...

Page 12: ...rod uct Or register your product on line at www ControlOMatic com First Name Last Name Address City State Province Postal Code Phone E Mail Please copy this section and forward a copy to ControlOMatic...