background image

Transmitting 

Power

Class 4 (33dBm±2dB) for GSM850 and EGSM900

Class 1 (30dBm±2dB) for DCS1800 and PCS1900

Class E2 (27dBm±3dB) for GSM850 and EGSM900 

8-PSK

Class E2 (26dBm±3dB) for DCS1800 and PCS1900 

8-PSK

Class 3 (24dBm+1.7/-3.7dB) for UMTS 

800/850/900/1900/21

Interface

Antenna

GSM/UMTS antenna, 50Ω, SMA-F Female con

-

nector

Digital inputs

2x 24 Vdc with optical isolation

Digital ou-

tputs

2x SSR with optical isolation

LED indica-

tors

4

SIM slot

microSIM

Plug-in 

extender

yes

Environment Conditions

Operating 

Temp

-20°C to +60°C

Storage 

Temp 

-20°C to +70°C

Operating 

/ Storage 

Humidity

 5 - 85% RH , non condensing

Protection 

Class

IP20

Dimensions and Weights

WxHxL

41.20x23.80x90.30 mm

Weight

0.2 Kg

Approvals

CE 

EN 61000-6-4, EN 61000-6-2, EN 61000-6-3, EN 

61000-6-1

EN 60945

ETSI EN 301 489-1, ETSI EN 301 489-52

EN 301 511

ETSI EN 301 908-1, ETSI EN 301 908-2

EN 62311

EN 60950-1

UL

cULus: UL61010-1 / UL61010-2-201

UL

cULus: Class I Div. 2

DNV-GL

Yes

RCM

Yes

WIRELESS MODEM

Behavior  of  the  wireless  modem  can  be  configured  from  the 

HMI device System Setting tool:

System Settings → Network → Mobile Network

The Mobile Network section is available only when the optional 

module is plugged to the HMI device.

PARAMETER

DESCRIPTION

Enabled

Enable the Wireless Modem

Autostart

Enable the Wireless Modem automatically 

when HMI device is power on

Potenza 

trasmittente

Classe 4 (33dBm±2dB) per GSM850 e EGSM900

Classe 1 (30dBm±2dB) per DCS1800 e PCS1900

Classe E2 (27dBm±3dB) per GSM850 e EGSM900 

8-PSK

Classe E2 (26dBm±3dB) per DCS1800 e PCS1900 

8-PSK

Classe 3 (24dBm+1.7/-3.7dB) per UMTS 

800/850/900/1900/21

Interfaccia

Antenna

GSM/UMTS antenna, 50Ω, SMA-F connettore 

femmina

Ingressi 

digitali

2x 24 Vdc con isolamento ottico

Uscite digitali 2x SSR con isolamento ottico
LED

4

SIM slot

microSIM

Estensione 

Plug-in

si

Condizioni ambientali

Temp. funzio-

namento

-20°C a +60°C

Temp. imma-

gazinamento

-20°C a +70°C

Umidità 

operativa / di 

stoccaggio

 5 - 85% RH , senza condensa

Classe di 

protezione

IP20

Dimensioni e peso

WxHxL

41.20x23.80x90.30 mm

Peso

0.2 Kg

Certificazioni

CE 

EN 61000-6-4, EN 61000-6-2, EN 61000-6-3, EN 

61000-6-1

EN 60945

ETSI EN 301 489-1, ETSI EN 301 489-52

EN 301 511

ETSI EN 301 908-1, ETSI EN 301 908-2

EN 62311

EN 60950-1

UL

cULus: UL61010-1 / UL61010-2-201

UL

cULus: Class I Div. 2

DNV-GL

Yes

RCM

Yes

MODEM WIRELESS

Il modem wireless può essere configurato dallo strumento Sy

-

stem Setting del pannello operatore:

System Settings → Network → Mobile Network

La sezione Mobile Network è disponibile solo quando il modulo 

opzionale è collegato al pannello operatore.

PARAMETRO

DESCRIZIONE

Enabled

Abilita il Modem Wireless

Autostart

Abilita automaticamente il Modem Wireless 

quando il pannello operatore è acceso

SIM PIN

Codice PIN della SIM card se richiesto

1

a

 Emissione / 1

st

 

Issue 

  06/19 

 2      DIM302

Reviews: